background image

 

 

 

PRETREATmaker III

 

Initial Setup 

1.  Do not install the nozzles until the very end of the initial setup listed below. 
2.  Place Deposit Tank (waste tank) on floor behind machine. Attached the hose provided. 

Trim the hose so it has no loops or kinks in the hose. 

3.  Fill the Bottle Distilled Water tank with 1 gallon of distilled water (This is located on the 

right hand side of the unit behind the removable door) 

4.  Put two parts distilled water and one part pretreat in the Precoating tank and swirl 

around to fully mix for approximately 1 minute.  You may wish to take a paper towel and 
cover the breather hole at the back of the tank when doing this to minimize any liquid 
coming out of the tank. 

5.  On the LCD Panel turn on all 4 nozzle zones. Attach the black hose (precoating hose) to 

the Distilled Water tank. Press and hold the Precoating button until the distilled water fills 
all 4 lines. This needs to be done to remove any air bubbles or containments from the 
lines.  

6.  To load the pretreat reconnect the black line to the precoating tank and pressing the pre-

coating button until the line is full of white solution.  This normally will take about 30 
seconds for the line to become filled. 

7.  Insert nozzles into the yellow quick exchange caps placing the rubber washer over the 

nozzle. Connect each of the quick exchange/rubber washer/nozzle assemblies onto the 
bottom of the black spray valves. They get secured by turning 90 degrees to lock into 
place. 

Calibration 

1.  Ensure that the unit is setup in inches by going to maintenance and touching the 

American flag if the unit is not currently setup in this manner.

 

2.  Setup conditions as follows. These are a starting points and adjustments may be 

necessary. Adjust the pressure and/or volume until you achieve correct gram value. 

 

Condition
   

Volume  Pressure 

Passes  

Begin 

Length 

F1 (Dark) 

1           
     

125% (+25%) 

Bidirectional  

11 

13 

F2 
(Med)    

1           
   

90% (-10%) 

Bidirectional  

11 

13 

F3 (Light)  2           

    

125% (+25%) 

Unidirectional    

11 

13 

 

 