manualshive.com logo in svg
background image

L E D H E I M E R

BROTHER, BROTHER & SONS ApS

USER MANUAL

Содержание LEDHEIMER

Страница 1: ...L E D H E I M E R BROTHER BROTHER SONS ApS USER MANUAL ...

Страница 2: ...ontact your regional dealer Contact information for your area can be found at www brothers sons dk RMA When returning an item please enclose a Model and Serial number b A description of the problem c The name of the owner of the equipment d If available please include a copy of your invoice to establish the date of sale and the beginning of the warranty period Disposing of this product Help preser...

Страница 3: ...ndex Safety Information Maintenance Product Overview Single Yoke Assembly Yoke Array Assembly First Time Usage Installation AC Power DMX Data Link Software Update DMX Protocol Software Menu Trouble Shooting FAQ Specifications 1 2 3 3 4 5 6 9 10 10 10 11 12 14 15 ...

Страница 4: ... that the fixture is electrically connected to ground earth Only use this product if all cables connectors and the product itself are undamaged Damage caused by inadequate cleaning or maintenance is not covered by the product war ranty This is a product using High power LEDs Do not stare directly into the LED at extended periods of time at a short distance without suitable protective eyewear Do no...

Страница 5: ...USER MANUAL 4 LEDHEIMER WWW BROTHERS SONS DK PRODUCT OVERVIEW 238 70 mm 9 39 284 mm 11 18 200 mm 7 87 185 50 mm 6 24 185 50 mm 6 24 233 65 mm 9 20 PowerCon IN DMX IN DMX OUT PowerCon OUT ...

Страница 6: ...USER MANUAL 5 LEDHEIMER WWW BROTHERS SONS DK SINGLE YOKE ASSEMBL Y Slide the fixture in to the yoke and insert the four ballpins ...

Страница 7: ...de refer to illustration above Insert ballpins in the the positions as shown Note that when inserting ballpins to interlock two Ledheimers only one ballpin is used on the side in question and always the one closet to the front These symbols mark the unused mounting holes The ballpins marked with a dotted circle comes with the mounting plates ...

Страница 8: ...USER MANUAL 7 LEDHEIMER WWW BROTHERS SONS DK YOKE ARRAY ASSEMBL Y Hex screw Washer Mounting plate Mount each mounting plate using 4 hex screws and 4 washers as illustrated But do not tighten them yet ...

Страница 9: ...RS SONS DK YOKE ARRAY ASSEMBL Y Parallel Angled Before tightening the screws that connects the fixtures to the mounting plates you will need to position the fixtures accord ing to the illustrations and your desired setup Parallel Angled ...

Страница 10: ...is within the range specified If so connect a power cable and turn the power on Standalone operation Using the navigation buttons and display readout refer to the Software Menu chapter navigate to Manual and set the desired intensity additional operations see Software Menu chapter DMX operation Connect a DMX cable Navigate to Adress mode Addr and set the desired adress resolution response strobe c...

Страница 11: ...pin XLR for dmx input and output Use shielded data cables Do not overload the daisy chain Up to a maximum of 32 devices can be used on a single dmx chain DMX Channels 1 at 8bit Dimmer 2 at 8bit Dimmer w strobe 2 at 16bit Dimmer 3 at 16bit Dimmer w strobe Protocol USITT DMX512 A SOFTWARE UPDATE Software can be updated via DMX512 with UPLOADER from Brother Brother Sons ApS and the latest software ve...

Страница 12: ...DOWN Decrease value MENU ENTER UP DOWN DMX Channels Mode Channel Parameter Value Percent Function 8 Bit 1 Dimmer 0 255 0 100 Coarse dimming 8 Bit 1 Dimmer 0 255 0 100 Coarse Dimming w Strobe 2 Strobe 0 5 0 Open mode 6 125 1 49 Slow to Fast Strobe 126 130 50 Open 131 250 51 99 Slow to Fast Random 251 255 100 Open 3 Strobe 0 0 100 Short to Long Flash length 16 Bit 1 Dimmer 0 255 0 100 Coarse dimming...

Страница 13: ...st received DMX value OFF Sets output to zero MAN Go to Manual DMX value Display OFF 2n Display off after 2 minutes ON Display always on Tools Ver Shows software version READOUT ONLY HW Ver Shows hardware version READOUT ONLY Temp LED temperature READOUT ONLY DMX In 3 first digits shows DMX adress READOUT ONLY 3 last digits shows DMX value READOUT ONLY Reset Confirm Reset unit by pressing enter te...

Страница 14: ...ubleshooting READOUT ONLY Log C Minimum and maximum logged temperature in C UP and DOWN scrolls min and max on time PSU on time in hours READOUT ONLY on LED LED on time in hours READOUT ONLY Demo Developer info DMX HZ DMX refresh rate READOUT ONLY DMX CH No of DMX ch transmitted by controller READOUT ONLY DMX br Break lenght of DMX in microseconds READOUT ONLY LED EE Developer info Manual 0 Manual...

Страница 15: ...ARDO 1 WWW BROTHERS SONS DK FAQ TROUBLESHOOTING Problem Possible Cause Solution Brother Brother Sons ApS The information in this manual is subject to change without notice Go to www brothers sons dk for the latest version ...

Страница 16: ...W This fixture must be connected to ground Thermal Maximum ambient temperature t Amb 40 C 104 F Cooling t Case temperature as shown in display Below 64 C 147 2 F Convection cooled Above 64 C 147 2 F Forced silent fan cooling Above 70 C 158 F Forced dimming Above 73 C 163 4 F Forced Lamp Off Accessories Uploader BBS Software Uploader City Theatrical Tophat AC Lighting 2402 CCT Minuette barndoor AC ...

Отзывы: