TYPICAL INSTALLATION
INSTALLER: LEAVE THIS
MANUAL WITH THE
HOMEOWNER.
HOMEOWNER: USE AND
CARE INSTRUCTIONS ON
PAGE 3.
MODEL HS110UE
ULTRA-SENSAIRE
®
HUMIDITY SENSING
CEILING FAN
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code au-
thorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
WARNING
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected
to a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
8. Never place a switch where it can be reached from a tub or
shower.
9. This unit must be grounded.
CAUTION
!
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. This product is designed for ceiling installation only.DO NOT
MOUNT THIS PRODUCT IN A WALL.
3. To avoid humidity sensor damage, motor bearing damage
and noisy and/or unbalanced impellers, keep drywall spray,
construction dust, etc. off power unit.
4. Please read specification label on product for further informa-
tion and requirements.
HOUSING
MOUNTING
BRACKET
CEILING
JOIST
POWER
CABLE
GRILLE
FINISHED CEILING
4" ROUND
DAMPER/DUCT
CONNECTOR
This unit can be installed anywhere between joists
using mounting brackets provided.
PLAN THE INSTALLATION
The location of your
ULTRA-SENSAIRE
®
fan is
very important. Follow
these guidelines for best
operation:
• The ULTRA-SENSAIRE
®
fan uses a humidity
sensor that responds to
both increases in humidity
and to humidity levels.
The humidity sensor may
turn the fan ON when
e n v i r o n m e n t a l
conditions change. If the
fan continuously
responds to changing environmental conditions, "SENSITIVITY"
adjustment may be required.
• Locate unit above (GFCI protected circuit required) or within 5 feet of
shower head.
• Locate unit away from heating or cooling sources which can affect
humidity levels.
• Do not locate near window. Unit may respond to the outdoor humidity
level.
• Unit must be installed in ceiling to properly sense moisture.
• Locate unit only on flat ceilings up to 12 feet high for proper sensing.
• The fan will operate most efficiently when located where the shortest
possible duct run and minimum number of elbows will be needed.
POWER
CABLE
SUSPENDED CEILING
MATERIAL
4" ROUND DUCT
HOUSING
1
Call 1-800-667-8721 anywhere in the US and Canada -