background image

USER

MANUAL

Ver 1,0

LED MOVING WASH

Summary of Contents for BT-54L3

Page 1: ...USER MANUAL Ver 1 0 LED MOVING WASH ...

Page 2: ...N 5 2 1 MOUNTING 5 2 2 6 2 3 SETTING UP STAND ALONE 6 2 4 SETTING UP MASTER SLAVE 7 2 5 SETTING UP DMX512 CONTROLLER 7 PART 3 DISPLAY PANEL OPERATION 8 3 1 BASIC 8 3 2 MENU 8 3 3 10 3 4 11 3 5 12 3 6 12 3 7 13 3 8 13 3 9 14 3 10 15 3 11 15 PART 4 USING A DMX512 CONTROLLER 16 4 1 BASIC ADDRESSING 16 4 2 CHANNEL ASSIGNMENT 16 4 3 BASIC INSTRUCTIONS FOR DMX512 OPERATION 19 PART 5 APPENDIX 20 5 1 TROU...

Page 3: ... from DMX512 controller This product can be operated as a single unit or with multiple units for large applications 1 1 PRODUCT INTRODUCTION RGBW Dimmer 0 100 Strobe Automatic programs Custom program programmable Auto color sequence variable speed LCD display Fan speed control DirectDMX512 input 1 2 PRODUCT FEATURES No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ITEM Head Side arm Handle Menu Enter Down Up S...

Page 4: ...FICATIONS 100 240V 50 60Hz 280W 54pcs 14 X 2W RED 14 X 3W GREEN 14 X 3W BLUE 12 X 3W WHITE Forced air convection 390 x 320 x 385mm 16Kg Voltage Rated Power LED Unit Cooling Dimensions Weight 1 PRODUCT GENERAL 2 2008 7 31 ...

Page 5: ... 3 2 4 6 8 10Distance m 5140 1373 620 350 238 LUX 15 GREEN 1 2 3 0 1 2 3 2 4 6 8 10Distance m 9360 2320 1055 602 398 LUX 15 BLUE 1 2 3 0 1 2 3 2 4 6 8 10Distance m 1710 420 192 110 73 LUX 15 RGB 1 2 3 0 1 2 3 2 4 6 8 10Distance m 16050 3920 1765 1010 670 LUX 15 RGB WHITE 1 2 3 0 1 2 3 2 4 6 8 10Distance m 20200 5400 2430 1400 950 LUX 15 ...

Page 6: ...rth wire must always be connected to the ground Do not touch the power cables if your hands are wet ATTENTION This product left the place of manufacture in perfect condition In order to maintain this condition and for safe operation the user must always follow the instructions and safety warnings described in this user manual Avoid shaking or strong impacts to any part of the equipment Make sure t...

Page 7: ...or objects because of movements of the fixture on the surface When the unit is mounted in a hanging position the fixture is attached using the mounting brackets and a standard truss clamp or other clamping device The mounting brackets supplied are mounted using quick release locks allowing simple mounting or removal UPRIGHT HANGING IMPORTANT SAFETY NOTE Always use a safety cable when installing th...

Page 8: ...ACEMENT 6 2 INSTALLATION 2008 7 31 The LED fixture can be used as a stand alone unit The stand alone functions AUTO 1 AUTO 2 CUSTOM can be activated without the need to connect to any controller or connecting to any other equipment Simply access the operation menu from the DISPLAY and select the target program to activate 2 3 SETTING UP STAND ALONE ...

Page 9: ...ection 2 2 All other units in the series should be set to SLAVE from the operation menu MASTER SLAVE SLAVE When units are connected in series to a DMX512 controller and other DMX512 equipment connect the equipment as shown in the diagram below Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller Connect the end of the cable coming from the c...

Page 10: ...Yes Custom DOWN ENTER UP MENU 3 1 BASIC The LED fixture is mounted with a LCD display and 4 control buttons MENU Scroll through the main menu or exit from the current sub menu ENTER Enter the currently selected menu or confirm the current function value DOWN Scroll DOWN through the menu list or decrease the value of the current function UP Scroll UP through the menu list or increase the value of t...

Page 11: ...GB 4 5 Fan 6 2password 0000 0000 6 Extra 6 1User key 000 255 No Yes 000 255 000 255 000 255 No Yes DMX System Normal Special No Yes DMX System 7 Calib 7 2 W2 3400K 7 3 W3 4200K 7 2 RED 7 2 GREEN 7 2 BLUE 7 3 RED 7 3 GREEN 7 3 BLUE 7 1 W1 3200K 7 1 RED 7 1 GREEN 7 1 BLUE 7 4 W4 4900K 7 4 RED 7 4 GREEN 7 4 BLUE 7 5 W5 5600K 7 5 RED 7 5 GREEN 7 5 BLUE 7 6 W6 5900K 7 6 RED 7 6 GREEN 7 6 BLUE 000 255 0...

Page 12: ... W7 6500K 7 7 RED 7 7 GREEN 7 7 BLUE 7 8 W8 7200K 7 8 RED 7 8 GREEN 7 8 BLUE 7 9 W9 8000K 7 9 RED 7 9 GREEN 7 9 BLUE 7 10 W10 8500K 7 10 RED 7 10 GREEN 7 10 BLUE 7 11W11 10000K 7 11 RED 7 11 GREEN 7 11 BLUE 7 12 RGB W 7 12 RED 7 12 GREEN 7 12 BLUE 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 0000 8 C...

Page 13: ... Enter to select the working mode of fan is for fast is for normal is for slow is for Auto Enter to select the operation mode Enter to select the DMX channel modes Enter to select the lighting time of the LCD display panel Enter to see the version of the software 11 3 DISPLAY PANEL OPERATION 2008 7 31 2 4 Use 2 3 Dimmer 2 2 Tilt 2 Invert 2 1 Pan Normal Reverse Normal Reverse Normal Reverse No Yes ...

Page 14: ...ystem MENU 3 6 SPECIAL 4 1 BlackDelay 4 1 BlackDelay No Yes 4 2Reset 4 2Reset DMX System 4 3 Dimmer When DIMMER is set to NORMAL then RGBW and MASTER DIMMER are linear CURRENT Vs DMX When DIMMER is set to SPECIAL then the dimming is not linear 4 4 RGB When RGB TO WHITE is set to Yes then when RGB 255 255 255 then the color is perfect white as the actual RGB values are adjusted to make white When R...

Page 15: ...8 codechange the default access code is 0000 6 2password When the user inputs the 6 2password the user is able to reset the DEFAULT values and get the administrator rights The password can be changed at 8 CodeChange the default access code is 1111 5 EDIT Enter the 5 EDIT mode to edit the custom programs by adjusting the value of 5 1STEP 5 2pan 5 3tilt 5 4speed 5 5 red 5 6 green 5 7 blue 5 8 white ...

Page 16: ...10 W10 8500K 7 10 RED 7 10 GREEN 7 10 BLUE 7 11W11 10000K 7 11 RED 7 11 GREEN 7 11 BLUE 7 12 RGB W 7 12 RED 7 12 GREEN 7 12 BLUE 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255...

Page 17: ...ord 8 2 Password elect to set the password elect to set the password Note will not appear only when 6 2 password is activated 3 11 DEFAULT 9 Default This functions will reset all setting to the original factory setting 15 3 DISPLAY PANEL OPERATION 2008 7 31 8 CodeChange 8 1 User key 8 2password ...

Page 18: ... 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 Note This product have two DMX512 channel configuration ADVANCED and BASIC 4 1 BASIC ADDRESSING Connect all of the unitsin series using standard DMX512signal cable Set the DMX512 address in the DMX menu It is possible to have the same DMX address or independent addresses for each fixture 4 2 CHANNEL ASSIGNMENT ADVANCED 16 4 USING A DMX512 CONTRO...

Page 19: ...an tilt black activated Pan tilt black deactivated Fan auto Fan slow Fan normal Fan fast No function Auto1 activated after 3secs Auto2 activated after 3secs Test activatedafter 3 secs Custom activated after 3secs No function Reset activated after 3secs No function NO FUNCTION RED UP GREEN 0 BLUE 100 RED 100 GREENUP BLUE DOWN RED DOWN GREEN 100 BLUE 0 RED 0 GREEN DOWN BLUE UP RED UP GREEN 0 BLUE DO...

Page 20: ... 8 7200K WHITE 9 8000K WHITE 10 8500K WHITE 11 10000K 0 255 0 255 0 255 0 255 0 255 0 255 0 5 251 255 6 25 26 45 46 65 66 85 86 105 106 125 126 145 146 165 166 180 181 190 191 200 201 205 206 210 211 215 216 220 221 225 226 230 231 235 236 240 241 245 246 250 0 255 0 255 0 19 20 39 40 59 60 79 80 99 100 119 120 139 140 149 150 159 160 169 170 179 180 189 190 199 200 219 220 255 CONTROL BASIC 18 4 ...

Page 21: ...sity of the color is the maximum CH6 CH7 CH8 CH9 can be combined together to create millions of colors COLOR MACRO WHITE The COLOR MACRO allows the user to select from a linear range of colors When the slider is at the top of the slider the color is WHITE DIMMER CH11 is an overall DIMMER for the currently selected created color STROBE CH12 is the strobe channel and controls the speed of the strobe...

Page 22: ...maged Replace main PCB board 26 2A LED603POWER 00 Display normal but no response to DMX 512 controller Signal connection error DMX Address error Check and replace signal cable Check and reset DMX address Fan do not work Fan error Fan actiyator Replace fan Replace fan actiyator 26 2A LED603FAPOWER 00 16 00 0043 00 Pan Tilt cannot reset Optical sensor PCB error Sensor PCB error Replace optical senso...

Page 23: ...for head Heat transfer plate LED board Display Board Side cover A Base upper cover 2 Power supply Base bottom cover Switch Fuse Power socket Handle Side coverB DMX board XY control board Plastic front cover No ITEM No ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Lens upper cover Lens base cover Lens LED board supporting base Plastic head cover ...

Reviews: