810nm Diode Laser   

                                                           

Model:HL-E810

 

 

                                              User Manual   

Summary of Contents for HL-E810

Page 1: ...i tech Co ltd ADD RM902 ShangMei Times NO 57 LongGuan RD Long Hua Dist Shenzhen China 518000 Tel 86 755 29994192 13148703639 Email sales bowei ch com http www bowei ch com 810nm Diode Laser Model HL E810 User Manual ...

Page 2: ...incerely recommend Before using the instrument please read this manual and keep it for future reference Please follow the instructions in the manual for correct installation use and operation Forbid disassemble this unit and modify any parts Except authorized personnel of this company it is forbidden for others to open the cover and disassemble the host computer Non professionals are strictly forb...

Page 3: ...power up to 100W bar the market single bar laser power generally 50W bar 80W bar 2 Efficient and stable cooling system Laser cooling system with constant temperature cooling to ensure that the entire system 7 24 hours of continuous work Air cooled water cooled way commonly used on the market can only work continuously for 2 hours 3 810nm precision wavelength for hair removal 1 The melanin in the h...

Page 4: ...r hair removal system using its unique long pulse laser penetrating the epidermis to the hair follicle site based on the principle of selective light absorption the laser energy is preferentially absorbed by the melanin in the hair and then lose the regeneration of hair while the course of treatment Application Hair removal armpit hair beard lip hair hair line bikini line limb hair Technical Param...

Page 5: ...www bowei ch com cooling Handle temperature 10 5 Shell material ABS plastic metal Supply voltage AC220V AC110V can be customized Instrument composition 1 Screen 2 Emergency switch 3 Power switch 4 Handle 5 Handle bracket 6 Water hole 7 Water filter 8 Main power switch 9 Handle interface 10 Power cord connector 11 Overflow hole 12 Drain hole Attachment list 1 Handle 1 ...

Page 6: ... of accessories 3 Check for any mechanical damage Handle installation 1 Install the handle bracket Connect the handle to the instrument then place the handle on the holder Note When the handle is connected make sure that the blue buttons on the top and bottom of the connector are completely ejected otherwise the water flow will not be easy to flow 2 Instrument water 1 Remove the fill funnel and co...

Page 7: ...192 13148703639 Email sales bowei ch com http www bowei ch com 1 Connect the power line and turn on the main switch of the instrument 2 Turn on the power switch emergency switch 4 Interface introduction 1 Start interface as shown below 2 After self test click ENTER key to enter the gender selection interface as shown below ...

Page 8: ...oice 2 Water flow monitoring 3 Water quality monitoring 4 Water temperature monitoring 5 Handle temperature monitoring 6 The number of shots 7 Back button 8 Site selection 9 Energy regulation 10 Frequency adjustment 11 Standby 12 Ready 13 Data saved 14 Data reset Operation Steps 1 Shaved hair Before the operation a shaving process leaving 1 2mm hair on skin to facilitate the absorption of light 2 ...

Page 9: ...ment from the system default energy to start operating if the operator feels too much heat then reduce the energy if there is a slight sense of thermal expansion the melanin is absorbed by the wavelength of 810nm laser light energy into heat hair follicle destruction of melanin there is the best results 3 Operation time Legs 10 15 minutes Arms 5 10 minutes Armpit 5 minutes lip hair 3 minutes for r...

Page 10: ...oid eating spicy alcohol and tobacco stimulating food 3 To avoid exposure good sunscreen wipe sunscreen Cream 4 After hair removal to avoid pulling hair by hand Good treatment hair removal Equipment maintenance precautions 1 it is recommended to replace pure water or distilled water every 1 month 2 The instrument should be placed at a temperature of 5 40 humidity not exceeding 80 clean and ventila...

Page 11: ... purchase by bill host warranty for 12 months the handle warranty for 3 months the warranty period of the fault non human phenomena free repair Exceed the warranty period can also be responsible for maintenance in accordance with the provisions of the company to collect spare parts and consumables costs shipping costs borne by the customer If you need to add or purchase please contact with the com...

Page 12: ...hina 518000 Tel 86 755 29994192 13148703639 Email sales bowei ch com http www bowei ch com Not in accordance with the correct use of instructions caused by the failure Warranty Card Product Name Customer Name Model Tel Purchase Date Address Repair date Issue Cause Maintenance Content Repair Man ...