Specifications

Input Power:

9.0 VDC to 15.0 VDC

Current Draw:

15 mA @ 12.0 VDC

Standby Power:

There is no internal standby battery.
Connect to DC power sources
capable of supplying standby power
if primary power fails. For each hour
of standby time needed, 15 mAh are
required.

 For  UL Listed

Requirements, four hours (60 mAh)
minimum are required.

• Coverage:

Broad (standard):

35 ft. x 35 ft. (10.7 m x 10.7 m)

Barrier (optional):

35 ft. x 10 ft. (10.7 m x 3.1 m)

Long Range (optional):

70 ft. x 10 ft. (21.4 m x 3.1 m)

Pet (optional):

35 ft. x 35 ft. (10.7 m x 10.7 m)

with 70 ft. (21.4 m) long range

Sensitivity:

Selectable for Standard or
Intermediate.

• Alarm Relay:

Form “C” reed relay with contacts rated
at 28 VDC, 125 mA maximum for DC
resistive loads.

Tamper Switch:

Normally Closed (with cover in place)
tamper switch. Contacts rated at
28 VDC, 125 mA maximum.

• Trouble Output:

A solid state open collector shorts to
ground (-) when the detector is in a
trouble condition. The maximum
current load is 25 mA. Vsat @10 mA =
0.5 VDC.

Temperature:

The storage and operating range is
 -40°F to +120°F (-40°C to +49°C). 

For

UL Certificated Installations, the
temperature range is +32°F to +120°F
(0°C to +49°C).

Options:

B335 Low Profile Swivel Mount
Bracket, B338 Ceiling Mount Bracket,
OMB93-3* Barrier Mirror, OMLR93-3*
Long Range Mirror, OMP93-3* Pet
Mirror.

*Shipped in packages of three.

NOTE:

Misalignment of the detector when using an optional
mounting bracket may reduce range and increase dead
zones.

•  

Reading Bosch Security Systems, Inc. Product Date Codes

For Product Date Code information, refer to the Bosch Security
Systems, Inc. Web site at: 

http://www.boschsecurity.com/datecodes/

2.0

Mounting

Avoid

Direct or

reflected

sunlight

Moisture

Moving objects

Hot or cold air

directed onto

sensor

Mounting Outdoors

Pets or animals



   

Tamper Switch

Configuration

Switches

T-Strip

LED

Location of major items - Circuit Board

Corner
Mounting
Holes (2)

Surface

Mounting
Holes (4)

Bracket Mounting

Hole

Mirror
Tracks (2)

Circuit Board

Retainer Tabs (2)

Rear enclosure and mounting holes

Wiring
Knockouts

The mounting surface should be solid and vibration free.

• Select a location that is most likely to intercept an intruder moving

across the coverage pattern. The recommended mounting
height range is 6.5 ft. to 8.5 ft. (2 m to 2.6 m).

• Remove the cover. Insert a thin flathead screwdriver into the

notch at the bottom of the cover and pry up.

• Remove the circuit board by depressing the circuit board retainer

tab and lifting the board out from the enclosure. Then remove
the mirror by sliding it towards the bottom and out of its tracks.

• Open the knock-out wire entrance and route the wiring through.

3.1

Surface or Corner Mounting

• Open two holes for surface or corner mounting.

• Mark the location for the mounting screws. Use the enclosure

as a template. Pre-start the mounting screws.

• Securely attach the detector.

• Replace the circuit board/mirror unit.

• Select the Vertical Angle.

Mirror Information: 

 The mirror is adjustable from +1° to -18°

vertically by sliding the mirror forward or back  and ±10° horizontally
by rocking the mirror side to side. To change the mirror, just pull it
out from its resting grooves.

NOTE:

Excessive handling of the mirror surfaces may lead to
performance degradation.

- The following chart will help you set the correct Vertical

Angle based on the mounting height, mirror type, and
desired range.

70(20)

Mounting

Height

Broad

Barrier

Long Range

6.5(2)

7.5(2.3)

8.5(2.6)

20(6)

35(10)

20(6)

35(10) 40(12)

-12°

-14°

-6°

-8°

-6°

-4°

-4°

-8°

-6°

-4°

-12°

-8°

-6°

-2°

-2°

-4°

Height and desired Range listed in feet (meters)

-10°

-10°

Summary of Contents for DS935Z

Page 1: ... 0 Mounting Avoid Direct or reflected sunlight Moisture Moving objects Hot or cold air directed onto sensor Mounting Outdoors Pets or animals Tamper Switch Configuration Switches T Strip LED Location of major items Circuit Board Corner Mounting Holes 2 Surface Mounting Holes 4 Bracket Mounting Hole Mirror Tracks 2 Circuit Board Retainer Tabs 2 Rear enclosure and mounting holes Wiring Knockouts The...

Page 2: ...system should be fully wired powered and programmed Turn LED Switch ON Replace the front cover NOTE All testing must be performed with the front cover in place Wait at least two minutes with no motion in the coverage area for the detector to setup Walk test across the coverage pattern The edge of the coverage is determined by activation of the LED Walk test the unit from both directions to determi...

Page 3: ...Feet M e t e r s F e e t 0 0 0 Mirror Segment to Pattern Reference View of Front Polished Surface A B C D E F G H I J K L M N O P Q 0 0 35 0 Top View Broad Coverage 0 17 5 10 7 5 35 B A D C E F G I H 5 35 Meters M e t e r s F e e t O P Q M N L J K Feet 17 5 M e t e r s Top View 10 7 1 5 0 Meters Feet F e e t 0 0 0 1 5 5 5 35 D C E F G I H L J K A B Barrier Coverage 35 Side View 10 3 M e t e r s 0 ...

Page 4: ... than twice the height of the pet and never lower than 3 ft 1 m Make sure the field of view is free of all furniture or other objects which the pet could climb or jump resulting in an unwanted alarm Mirror Segment to Pattern Reference View of Front Polished Surface A BCD E FGH I 0 0 0 Top View Pet Coverage 0 17 5 5 35 B A D C E F G I H 5 35 Meters M e t e r s F e e t Feet 17 5 21 4 70 Side View Mi...

Reviews: