background image

System overview

-

 

1

2

3

4

5

6

7

10

9

11

12

8

1

Wiring knockouts

2

Cable tie / strain relief

3

Circuit boards retainer tabs

4

Bracket mounting hole

5

Mirror tracks

6

Corner mounting holes

7

Surface mounting holes

8

Securing screw

9

Tamper switch

10

LED

11

Terminal block

12

Circuit board

Installation

Avoid the following inside the monitoring
area:

direct hot or cold drafts and air condi-
tioning outlets

heat sources (a minimum distance of
1.5 m to a radiator is necessary)

windows

small animals

direct sunlight

The detector cannot detect through glass.

When using two or more detectors, the best
coverage is achieved by overlapping the
monitoring areas. The detectors do not af-
fect each other.

Installation preparations

1.

Select a surface that is solid and free of
vibrations. In order to ensure the intru-
sion security of dropped ceilings, detect-
ors should monitor each other.

Mounting

Notice!

 Removing masking from the mirror ele-

ments leaves adhesive residue that pollutes the
mirror and leads to malfunction of the detector.
VdS requirements prohibit mirror masking.

1. To remove the cover, insert a thin blade

screwdriver into the notch at the bottom and
pry it open.

2. To remove the circuit board, press one of

the circuit board retainer tabs towards the
side of the enclosure and lift the circuit
board out of the enclosure base.

3. Slide the mirror out of its tracks.

Notice!

 To exchange the mirror, remove the

current mirror and slide the other mirror into
the tracks.

4. Open an appropriate wiring knockout by tap-

ping it with a screwdriver then route the wir-
ing through the opening.

5. For strain relief, attach the cable to the

cable tie with the supplied plastic tie-down.

Surface or corner mounting

1. Open either two of the four surface mount-

ing holes or the two corner mounting holes.

2. Use the enclosure as a template and mark

the location for the mounting screws.

3. Firmly mount the detector with appropriate

hardware depending on the mounting sur-
face (e.g., anchors).

4. Insert the mirror and circuit board.

Bracket mounting

Notice!

 When using a bracket, misalignment of

the detector might reduce the monitoring range.

1. Mount the bracket to the mounting surface.
2. Knock out the bracket mounting hole in the

enclosure base and attach the enclosure to
the bracket.

3. Insert the mirror and circuit board.

For more information on the bracket mounting,
refer to the installation manual of the bracket.

Selecting the vertical angle of the mirror

!

Caution!

Excessive handling of the mirror sur-
face may lead to damage and malfunc-
tion of the detector.

Mounting

height

Wide-angle

mirror

Curtain mirror

2.0 m

-6°

-2°

2.3 m

-8°

-2°

2.6 m

-10°

-4°

Notice!

 The vertical angle adjustment marks can

be found on the mirror.

1.

Slide the mirror forward or backward un-
til the appropriate angle adjustment
marks are in line with the marks on each
side of the frame.

-16

-8

0

+2

+2

0

-8

-16

+2

0

-8

-16

Connection

Danger!
Injuries and damage of the detector
due to electricity are possible. Inspect
all connections to be correct before ap-
plying power.

1.

Connect the shielded cable to the ter-
minal block as shown in the figure below.

1

2

3

4

5

6

7

1 + 2

aLSN1, bLSN1: coming from the preced-
ing LSN element

3 + 4

aLSN2, bLSN: going to the next LSN ele-
ment

5 + 6

Spare terminal

7

Connection for ground wire from shiel-
ded cable

For element 1 – 4: Use shielded cable for bus
connections.

Notice!

Do not coil excess wire inside the en-
closure or seal the wire entrance with
the plug provided.

Configuration

1.

Set the sensitivity to one of the following
settings using the software:

Standard sensitivity (default)

Protection against false alarms

Tolerance to extreme environmental condi-
tions

Not recommended for curtain mirror version

High sensitivity

Recommended setting for any location
where an intruder is expected to cover only
a small portion of the monitoring area or
when quick catch performance is desired

Tolerance to normal environmental condi-
tions

High response sensitivity

1 |

2 |

3 |

4 |

5 |

6 |

7 |

8 |

Reviews: