manualshive.com logo in svg
background image

1

6

0

3

5

16

0

4

 

E

N

VENDING

FONTEMAGNA

Us

e

 

&

 M

ai

nte

na

n

c

e M

a

n

u

a

l

Содержание FONTEMAGNA Light

Страница 1: ...1 6 0 3 5 8 1 6 0 4 EN VENDING FONTEMAGNA Us e M a i n t e n a n c e M a n u a l ...

Страница 2: ......

Страница 3: ...TIONS AND GENERAL RECOMMENDATIONS 8 DESCRIPTION OF THE UNIT 9 DESCRIPTION OF THE KEYPAD 12 TECHNICAL FEATURES 13 INSTALLATION 16 OPERATION 20 INSTALLATION OF THE CO2 CYLINDER FIZZ MODEL 28 HANDLING THE GAS CYLINDERS 29 FILTRATION OPTIONAL 30 SANITIZATION NOTES 32 MANAGEMENT OF ALARMS AND MALFUNCTIONS 33 ORDINARY MAINTENANCE 34 SERVICE HISTORY 35 WARRANTY CONDITIONS 36 ...

Страница 4: ...PURA product We have designed and manufactured this product with great care to ensure that it will dispense water of the highest quality In order to get the most out of your water cooler please read the instructions in this manual and retain the manual for future reference ...

Страница 5: ...ct should not be treated as domestic waste but should be taken to a dedicated recycling centre for electrical and electronic equipment Immediately prior to scrapping cut off the power cable For more information on the treatment recovery and recycling of this product please contact the appropriate local office the waste disposal service or the reseller from which the product was purchased Informati...

Страница 6: ...e components pursuant to the current legislation In addition the unit is manufactured in compliance with Italian Ministerial Decrees 174 of 06 04 2004 and 25 of 07 02 2012 Electrical safety This water cooler is designed manufactured and marketed in compliance with the safety objectives of the Low Voltage Directive 2006 95 EC the protection requirements of the Electromagnetic Compatibility Directiv...

Страница 7: ...ARDS 2015 ROME 2014 BEST PROMOTION OF HEALTH AND HYDRATION EUROPEAN AQUA AWARDS 2014 BUDAPEST 2013 BEST PRODUCT INNOVATION EUROPEAN AQUA AWARDS 2013 BERLIN 2012 BEST ENVIRONMENTALLY FRIENDLY PRACTICE EUROPEAN AQUA AWARDS 2012 ISTANBUL 2011 BEST PRODUCT DESIGN INNOVATION EUROPEAN AQUA AWARDS 2011 ODESSA 2010 BEST ENVIRONMENTALLY FRIENDLY PRACTICE EUROPEAN AQUA AWARD 2010 PRAGUE ...

Страница 8: ... the refrigerant circuit are not damaged The unit is not intended for use by children If the power cable is damaged it must be replaced by the manufacturer by its technical support service or by a qualified technician Do not use extension cables or multi plugs Ensure that it is possible to disconnect the power supply either by removing the plug or via a two pole circuit breaker placed upstream of ...

Страница 9: ...urs 28 lt continuous to fill bottles carafes sport bottles etc Dual cooling coil one for cold water and one for sparkling water with the option for simultaneous dispensing 2 dispensing options cold water cold sparkling water Dispensing of pre set quantities of water the quantities are easily programmable thanks to the volumetric control Professional stainless steel carbonator Self diagnosis and al...

Страница 10: ...10 Front View 1 4 3 2 1 8 7 6 5 2 3 4 5 6 7 8 Payment display Dispensing nozzle Drip tray Payment reader Keypad Front panel security lock Adjustable front feet Rear wheels ...

Страница 11: ... 7 7 6 5 Ice bank overflow outlet pipe OD17xID12 mm Power cable Drinking water inlet pipe Ø3 8 Ø9 5 mm for mod 150 or Ø5 16 Ø8 mm for mod 80 8 Drip tray waste pipe Ø40 mm 4 3 2 1 Top section Top section screws Rear panel Hinges ...

Страница 12: ...sing system The dispensing quantities are easily PROGRAMMABLE during installation On turning on the unit the default settings are as follows the upper buttons dispense 50 cl of water a cupful whereas the lower buttons dispense 100 cl To customize the dispensing quantities for each button read the section Operation page 20 To dispense water insert the card in the reader and push the button ...

Страница 13: ...13 Technical Features Technical Data Plate 16 Year of manufacture 03 Month of manufacture 00700 Serial number mod Fontemagna Vending ...

Страница 14: ...14 Technical Features dimensions mm mod Fontemagna Vending ...

Страница 15: ...ce bank 8 kg 5 kg Power supply Single phase 230V 50Hz Power consumption 650W 2 6 A 520W 2 3 A Compressor output kcal h 700 360 Cooling Forced ventilation Refrigerant gas Natural gas HC R290 Ambient cooling temperature Min 5 C Max 35 C Sound pressure level 70dB Dimensions LxDxH mm 520x505x1450 520x505x1450 Packaging dimensions mm 600x600x1630 600x600x1630 Net weight kg 50 45 Gross weight kg 55 50 r...

Страница 16: ...possible after delivery If the unit has been shipped horizontally or at an angle it will be necessary to wait at least 8 hours before setting it up in order to allow the cooling circuit to reset itself Ensure that the unit is installed and connected to the main supply by a qualified technician in compliance with the manufacturer s instructions and the local safety guidelines The end user is not pe...

Страница 17: ...able front feet Leave at least 4 inch around the unit to allow for aeration Filling the Ice Bank Open the service panel using the supplied key Gently pour drinking water into the tank through the hole 1 The ice bank is completely full only when water starts to come out of waste water tube on the back of the machine 1 Fig 18 1 Once you have filled the ice bank avoid moving the unit If you have to m...

Страница 18: ... equipped with a tap 4 left in the on position a mechanical filter 5 a water pressure reducer 6 not included in version 80 lt h a safety valve 7 and a non return valve 8 Connect waste pipes 3 and 1 to a waste water manifold Once the pipes are attached turn on the tap Ensure there are no leaks Caution To connect the water cooler to the mains water supply you will need to use a new set of connectors...

Страница 19: ...g the carbonator with water is also activated If the payment is disabled read section 4 Enabling disabling payment page 24 press the Sparkling Water button in order to release any air in the circuit and to allow the pump to fill the carbonator with water Otherwise insert the card in the reader Fig 19 3 and press the button After around 1 2 minutes the sparkling water pump stops Thermostat The ther...

Страница 20: ...nt has been enabled insert the card into the reader On the display check the amount of credit on the card READY TIME CARD CREDIT If there is insufficient credit on pressing the button for the required quantity the following message will be shown on the display INSUFF CREDIT COST COST PRODUCT If there is sufficient credit press the dispensing button for the desired product STILL or SPARKLING and th...

Страница 21: ...ows the following message READY TIME If payment has been enabled see section 4 Enabling disabling payment page 24 the following scrolling text appears INSERT CARD This text can be modified using the programming button panel see section 2 Stand by mode texts page 23 The LEDs of the programming button panel will be constantly lit Setting of quantities From stand by mode press button 5 on the program...

Страница 22: ...ing text appears CLOCK SETTING hh mm day Use buttons 1 and 2 respectively to increase and decrease the value in each field hh hours mm minutes day days of the week and use button 5 to move from one field to the next Press button 5 again to display the number of litres dispensed sub divided between still water and sparkling water and between total count and partial count Each time button 5 is press...

Страница 23: ...ISH FRENCH Press button 5 to confirm the language and proceed to the next function 2 STAND BY MODE TEXTS In stand by mode the display will alternately show 3 strings that can be modified to provide information to the user SCRIPT 1 STRING As the default the field associated with SCRIPT 1 and 3 are left blank To enter a string with a maximum of 16 characters use button 3 on the programming button pa...

Страница 24: ...o the next product name PRODUCT NAME 2 STILL 1 0 L PRODUCT NAME 3 STILL 1 5 L PRODUCT NAME 4 SPARKLING 0 5 L PRODUCT NAME 5 SPARKLING 1 0 L PRODUCT NAME 6 SPARKLING 1 5 L On the Fontemagna Vending with 4 dispensing buttons 2 for still water and 2 for sparkling water product 3 and product 6 do not correspond to any of the buttons Press button 5 to move on to the subsequent functions 4 ENABLING DISA...

Страница 25: ...an change the product price expressed in Euros PRODUCT PRICE 1 0 50 Press 5 to confirm and move on to the next product cost PRODUCT PRICE 2 0 50 PRODUCT PRICE 3 0 50 PRODUCT PRICE 4 0 50 PRODUCT PRICE 5 0 50 PRODUCT PRICE 6 0 50 On the Fontemagna Vending with 4 dispensing buttons 2 for still water and 2 for sparkling water product 3 and product 6 do not correspond to any of the buttons Press butto...

Страница 26: ...on of the machine the user can suspend the supply of water by pressing the dispensing key a second time The user has a period equal to the value set to complete the delivery of the selected dose If the value is zero the function is not active Press button 1 or 2 to decrease or increase the default value N TELEPHONE STRING By default this field is empty Enter the phone number to which the machine c...

Страница 27: ...rn on the payment circuit leaving pressed the buttons above on the display appears CITYEXT 1 09B 3 Continue holding the keys until on the display the message appears PRESET VALUES COMPLETED The LEDs on the keypad are off 4 Turn off and on the machine at the main switch ...

Страница 28: ...sions The unit is equipped with a tear tape for the safety fixing of the cylinder Photo 26 1 shows a 4 kg cylinder with a total height of 580 mm To increase or decrease the level of carbonation of the water you need to adjust the screw 1 Turning it clockwise increases the level of carbonation We recommend that you do not exceed 4 bar of pressure 2 To reduce the carbonation level turn the screw ant...

Страница 29: ...er cylinders or surfaces dropping the cylinders or subjecting them to mechanical stress All of the above may compromise their integrity and resistance The cylinders must not be lifted by the cap or dragged rolled or slid along the floor Even if only being moved for short distances an appropriate hand cart or other suitable means of transport should be used Do not use magnetic lifters or slings wit...

Страница 30: ...ntaminants such as asbestos fibres and micro organisms such as Cryptosporidium and Giardia It protects gaskets pumps tubes and valves against blockages corrosion and abrasions Approved by the Italian Ministry of Health and the Water Regulations Advisory Scheme UK it is certified compliant with the NSF ANSI standards 42 and 53 The cartridge should be changed every 6 MONTHS Its maximum capacity is 1...

Страница 31: ...ure 9 bar Radiation 30000 μWs cm Green LED ON lamp lit Maximum capacity of the lamp 9000 h max 12 months The UV sterilizer is made entirely in Italy and complies with Italian and European quality and safety guidelines Caution The light emitted by the ultra violet lamp may cause serious burns to the eyes and skin Do not remove it from its stainless steel container only a qualified technician should...

Страница 32: ...ed technical personnel who have completed specific training courses on hygiene and sanitization To sanitize the unit we recommend the use of hydrogen peroxide oxygenated water 5 diluted in drinking water For more details on this operation consult the SANITIZATION section in the BLUPURA technical manual Filter replacement and sanitization All of the operations must be carried out exclusively by qua...

Страница 33: ... water flow at the inlet If the inlet flow is reduced and the normal flow level is not restored within 4 minutes the electronic circuit protects the internal pump by cutting off the power supply to it Check that there has been no interruption to or reduction of the mains water service and that the water flow at the inlet has not been reduced by blockages of any sort e g due to an excess use of car...

Страница 34: ...cidity risks ruining the surface of the steel DO NOT USE alcohol or solvent based products Cleaning the drip tray When it is necessary to clean the drip tray use a diluted limescale cleaner citric acid or similar The drip tray can also be washed in the dishwasher Cleaning the dispensing nozzles On a daily basis spray our SANIFICATION SPRAY code 190010 onto the nozzles Alternatively you can use a d...

Страница 35: ...35 Service history Installation Technician Date Notes Signature Maintenance Technician Date Notes Signature ...

Страница 36: ...he free of charge replacement of any parts that have been shown to have manufacturing defects The warranty does not include normal wear and tear to the components or any damage caused to the components due to negligent or improper use or due to a non standard installation The warranty shall not be applicable if the unit has been tampered with or if repairs have been carried out by unauthorized per...

Страница 37: ...37 ...

Страница 38: ...38 ...

Страница 39: ...39 160358 Rev 00 13 05 2016 10 02 ...

Страница 40: ...pura srl Registered office Via F lli Brancondi 56 60025 Loreto AN Italy Headquarters Via Erideo Marinucci 2 4 62019 Recanati MC Italy Tel 39 071 9710080 Fax 39 071 9710084 info blupura com www blupura com ...

Отзывы: