Page 2: ...pares tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales ...

Page 3: ...nstallation 7 Installation Requirements Unpacking Location Clearances Wall Mounting to non combustible wall only Gas Connection Commissioning Operation 12 Operation Guide Description of Controls Lighting Main Burners Racking System Cooking Recommendations Cleaning and Maintenance 14 General Racking Stainless Steel Surfaces Vitreous Enamel Surfaces Trough Tray Fault Finding 16 Gas Conversion and Sp...

Page 4: ...ISK OF FIRE THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATI...

Page 5: ...om flat to angled position by partial removal of rack Rack height must be fully removed for repositioning of rack height setting Branding Plate is available as an accessory item Refer to Replacement Parts List G91B Rack supports have 4 fixed height positions offering flat and angled rack positioning Rack can be changed from flat to angled position by partial removal of rack Rack height must be ful...

Page 6: ...Gross Nominal 8 8 kW 8 8 kW Reduced 3 6 kW 2 6 kW Gas Rate Nominal 0 84 m3 hr 0 63 kg hr Reduced 0 34 m3 hr 0 19 kg hr Supply Pressure 20 mbar 37 mbar Burner Operating Pressure 10 mbar 26 mbar Gas Connection 1 2 BSP Male Natural Gas LP Gas Propane Input Rating N H G C 31 5 MJ hr 31 5 MJ hr Supply Pressure 1 13 3 4 kPa 2 75 4 5 kPa Burner Operating Pressure 1 0 kPa 2 55 kPa Gas Connection BSP Male ...

Page 7: ...rsion and Specifications section of this manual for further details Gas Connection Gas supply connection point is located 25mm in from the rear of the appliance 130mm from the right hand side and is entered from beneath appliance Connection is BSP male LP Gas Propane Butane Input Rating N H G C 31 5 MJ hr 31 5 MJ hr Supply Pressure 2 75 4 50 kPa 2 75 4 50 kPa Burner Operating Pressure 2 55 kPa 2 5...

Page 8: ...mensions Dimensions Internal Dimensions Width 685mm Height 230mm at front Depth 330mm Cooking Area Rack 610mm x 310mm Branding Plate 610mm x 310mm Weight Nett 41 kg without Branding Plate or Racking System ...

Page 9: ...he installation person Unpacking Remove all packaging and transit protection from appliance including all protective plastic coating from exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to carrier and distributor Report any deficiencies to distributor who supplied appliance Check available gas supply is correct to as shown on rating plate located ...

Page 10: ...ombustible material NOTE Do not obstruct or block appliances flue Never directly connect a ventilation system to appliance flue outlet Clearances NOTE Only non combustible materials can be used in close proximity to this appliance We recommend allowing a clearance of 100mm on either side of appliance to allow access to side panels for servicing purposes Using wall mounting accessories provided wit...

Page 11: ...lastic spacers to top rear corners of unit Leave them unscrewed by approximately 5mm 3 Fit two adjusting screws bolts into nutserts at bottom rear corners of unit These should protrude approximately 30mm from rear of Salamander 4 Lift Salamander onto wall bracket lining up black plastic spacers on salamander with mounting notches in bracket 5 Lower Salamander onto mounting bracket 6 Tighten black ...

Page 12: ...g installation NOTE It is important that adequately sized piping runs directly to connection joint on appliance with as few tees and elbows as possible to give maximum supply volume 3 Fit gas regulator supplied into gas supply line as close to appliance as possible NOTE Gas pressure regulator provided with this appliance is convertible between Natural Gas and LPG as per Gas Conversion Section in t...

Page 13: ... appliance Commissioning 1 Before leaving the new installation a Check the following functions in accordance with operating instructions specified in Operation section of this manual Light the Main Burners Check the Low Fire burner operation Check the High Fire burner operation Check the Racking System operation b Ensure the operator has been instructed in areas of correct lighting operation and s...

Page 14: ...nutes for elements to heat up Blue Seal salamanders provide two independently controlled heat zones High speed grilling is provided by two infrared gas burners in ceiling of grilling compartment The left and right hand gas control knobs operate left side and right side burners respectively independently of each other Each burner is provided with flame failure protection for main burner Gas Control...

Page 15: ...easy loading of food Installation of rack is dependent on cooking function required Cooking Recommendations 1 The G91B Salamander has been designed to give a good evenness of heat across rack area so toasting cheese melting and grilling should be relatively even wherever food is placed 2 The HIGH position is recommended for most grilling cheese melting functions and LOW for a reduced heat 3 For co...

Page 16: ...Remove left and right hand side racks from unit by removing single securing screw from each side rack 5 Withdraw left and right hand side racks from unit 6 Refit Racking in reverse order once cleaning has been completed Stainless Steel Surfaces Clean with detergent Baked on deposits or discolouration may require a good quality stainless steel cleaner or stainless steel wool Always apply cleaner wh...

Page 17: ...as control knobs from gas tap spindles by pulling knobs away from control panel b Remove drip tray from appliance c Remove two screws on underside of control panel securing control panel to hob and remove control panel from front of appliance d Remove 2 screws holding shaft plate to gas control body and remove control shaft and plate See Fig 9 Note orientation of shaft for correct re assembly e Us...

Page 18: ...rol knob released Releasing knob before thermocouple has heated Main Burner flame too small Gas pressure too low Partially blocked main injector Thermocouple faulty Hold knob in for at least 20 seconds following ignition of main burner Call service provider Call service provider Main burners will not light No gas supply Incorrect supply pressure Blocked main injector Faulty gas control Ensure gas ...

Page 19: ...ls Main burner injectors 2 Remove main burner injectors and replace with correct size injectors as shown in Gas Specifications tables at rear of this section Low Fire Adjustment 1 Remove the following Gas control knobs from front of unit Two front control panels 2 Light main burners and check flame size on Low position Adjust burner gas control valve low fire adjustment screw as shown in Gas Speci...

Page 20: ...equired 5 Screw cap nut back onto regulator Gas Type Labels On completion of the gas conversion replace the gas type labels located at Rear of the appliance above the gas connection point Beside the rating plate Commissioning Before leaving installation 1 Check all gas connections for leaking using soapy water or other gas detecting equipment 2 Carry out a Commissioning check of the appliance as s...

Page 21: ...1 00mm Adjustment 2 turns out c c w turn out c c w Burner Operating Pressure 10 mbar 26 mbar Gas Regulator Cap Screw Supply Pressure 20 mbar 37 mbar Natural Gas LP Gas Propane Main Burner Injectors Ø 1 85mm Ø 1 15mm Low Fire Size Ø 1 00mm Ø 1 00mm Adjustment 2 turns out c c w turn out c c w Supply Pressure 1 13 3 4 kPa 2 75 4 5 kPa Burner Operating Pressure 1 0 kPa 2 55 kPa Gas Regulator Cap Screw...

Page 22: ...fer to Gas Conversion and Specifications section of this manual for further details Natural Gas Town Gas Main Burner Injectors Ø 1 85mm Ø 3 50mm Low Fire Size Ø 1 00mm Ø 1 00mm Adjustment 2 turns out ccw 4 turns out ccw Supply Pressure 1 13 3 40 kPa 0 76 1 50 kPa Burner Operating Pressure 1 00 kPa 0 63 kPa Gas Regulator Cap Screw Adjustable Regulator Adjust to the Burner Operating Pressure LP Gas ...

Page 23: ...96 Wall Mounting Bracket 017963 Rack 013395 Rack Handle 026093 Side Rack 227961 Screw Side Rack 227950 Trough Tray 013418 Branding Plate XP UK only Gas Regulators Gas Conversion Kits IMPORTANT Only genuine authorized replacement parts should be used for servicing and repair of this appliance Instructions supplied with parts should be followed when replacing components For further information and s...

Page 24: ......

Reviews: