background image

GAS PASTA COOKER 

 

 G47 

I N S T A L L A T I O N   A N D   O P E R A T I O N   M A N U A L  

232425-5 

Содержание Evolution series G47

Страница 1: ...GAS PASTA COOKER G47 I N S T A L L A T I O N A N D O P E R A T I O N M A N U A L 232425 5 ...

Страница 2: ... 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales tel 44 121 327...

Страница 3: ...s Assembly Gas Connection Water Connection Drainage Connection Commissioning Operation 10 Operation Guide Description of Controls Before Use Filling the Tank Lighting the Pilot Burner Lighting the Main Burner Turning OFF the Pasta Cooker Cleaning and Maintenance 13 General Draining and Cleaning After Each Use Daily Cleaning Weekly Cleaning Periodic Maintenance Fault Finding 16 Wiring Schematic 17 ...

Страница 4: ...RUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCATION THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER WARNING GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF FIRE THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE ...

Страница 5: ...ner Operating Pressure test point on the gas control valve with the burner operating at the High Flame setting NAT LPG Butane Only The operating pressure is ex factory set and is not to be adjusted apart from when converting between gasses if required TOWN GAS Only The burner operating pressure is to be adjusted using the adjustable gas regulator supplied Town Gas Option is only available with spe...

Страница 6: ...ar connection is available Connection is 3 4 BSP male Water Supply Requirements A cold water supply must be connected to the water inlet connection R 1 2 BSP located 50 mm from the LH side 556 mm from rear and 150 mm from the floor This should be plumbed in in accordance with National Local Codes covering installation Maximum water supply pressure 550kPa 80psi Tank capacity 40 ltrs of water Specif...

Страница 7: ...5 Dimensions G47 Pasta Cooker ...

Страница 8: ...int sealed by manufacturer are only allowed to be adjusted by an authorised service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from the appliance including all protective plastic coating from the door outer panel and exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to the carri...

Страница 9: ...FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED SERVICE PERSON 1 Blue Seal Pasta Cookers do not require an electrical connection they function totally on the gas supply only 2 It is essential that the gas supply is correct for the appliance to be installed and that adequate supply pressure and volume are available The following checks should therefore be made before installation a The Gas Type the...

Страница 10: ...for leakages using soapy water or other gas detecting equipment NOTE Burner operating pressure is to be measured at manifold test point with the burner operating at the High Flame setting NAT LPG Butane Only The operating pressure is ex factory set and is not to be adjusted apart from when converting between gasses if required TOWN GAS Only The burner operating pressure is to be adjusted using the...

Страница 11: ... BSP drain overflow Commissioning The following commissioning checks must be carried out before the pasta cooker is handed over for use to ensure that the unit operates correctly and the operator s understand the correct operating procedure 1 Before leaving the new installation a Check the following functions in accordance with the operating instructions specified in the Operation section of this ...

Страница 12: ...single main burner and pilot burner and is controlled by a single gas controller with flame failure protection to control both main burner and pilot Open tank design to simplify cleaning operation G47 Pasta Cooker Controls CAUTION This appliance is for professional use and is only to be used by qualified persons Only qualified service persons are to carry out installation servicing or gas conversi...

Страница 13: ... water flow out of the water supply nozzle that just causes water to continually flow out of the overflow This method provides Maintained water level for cooking Skimming or flushing effect to prevent the cooking water becoming gummed up with pasta residue WARNING GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE PASTA COOKER SAFELY TO GUARD AGAINST THE RISK OF INJURY AND FIRE DO NOT LEAVE THE P...

Страница 14: ...now ignite automatically off the pilot burner 2 The gas control knob can be regulated between the High Flame and the Low Flame position to regulate the cooking temperature 3 It will take approximately 30 minutes to heat the water in the tank from 20 C to 100 C Turning Off the Pasta Cooker To the Pilot Position a Depress and rotate the gas control valve clockwise to the Pilot position b The main bu...

Страница 15: ...ure that protective gloves are worn during the cleaning process Clean the pan regularly after each use Draining and Cleaning Opening the Drain Valve a Lift the locking slide on valve handle Fig 5 to release the valve b While holding the locking slide in the withdrawn position rotate the handle anticlockwise Fig 6 to open the valve c When the valve is closed slide the locking slide down over the lo...

Страница 16: ...g a damp cloth lightly moistened with a solution of mild detergent and hot water Dry the control panel thoroughly using a dry clean cloth 5 Clean the interior and exterior of the pan regularly at the end of each day Do not use wire brushes on the pan Clean using a mild detergent and a hot water solution using soft cloth or a soft bristled brush Dry the appliance thoroughly using a dry clean cloth ...

Страница 17: ... and can be removed to allow cleaning of the front of the control panel b Baked on deposits or discolouration may require a good quality stainless steel cleaner or stainless steel wool Always apply cleaner when the appliance is cold and rub in the direction of the grain c Dry all components thoroughly with a dry cloth and polish with a soft dry cloth Periodic Maintenance NOTE All maintenance opera...

Страница 18: ...checks out satis but the problem still persists The gas control valve is defective and needs replacement Pilot Burner delay in ignition of main burners Check operating pressure as stated in Installation section Increase by adjusting pilot adjustment screw on gas control Check pilot flame adjustment Pilot flame for main burner ignition should be approximately 1 inch long Check pilot burner size is ...

Страница 19: ...17 Wiring Schematic G47 Pasta Cooker ...

Страница 20: ...and ensure that the supply pressure is within the specification shown in the Gas Specifications Table at the end of this section Main Burner Injectors 1 Unscrew and remove the main burner injectors 12 7mm A F located in front of main burner venturi openings 2 Determine the correct injectors for the corresponding gas from the Gas Specifications Table at the end of this section 3 Screw in the correc...

Страница 21: ...ns 2 Unscrew hexagonal cap 23 mm A F from regulator 3 Un clip plastic pin from cap rotate pin and re fit back to cap the correct way for gas type to be used Either LP or NAT should be visible on flank of pin once re fitted to the cap 4 Screw the cap back into the regulator Town Gas Only 1 Unscrew and remove the slotted cap from the regulator 2 Turn on the gas supply and the appliance 3 Adjust pres...

Страница 22: ...ting Pressure test point on gas control valve with burner operating at High Flame setting NAT LPG Butane Only The operating pressure is ex factory set and is not to be adjusted apart from when converting between gasses if required TOWN GAS Only The burner operating pressure is to be adjusted using the adjustable gas regulator supplied Town Gas Option is only available with specific ex factory buil...

Страница 23: ...0 Water Drain Valve 229823 Overflow Hose 227850 Adjustable Leg 150mm Accessories Optional 228793 Plinth Kit 229837 Pasta Cooker Basket 320 x 165mm Regulator 228531 Regulator Natural Gas LP Gas Butane Convertible BSP F F 230185 Regulator Town Gas Adjustable BSP F F Replacement Parts List When ordering spare parts please quote the part number and the description as listed below If the part required ...

Страница 24: ...available with specific ex factory built Town Gas models which can also be converted to any other gas Standard models can only be converted between Nat Gas LP Gas and Butane but not Town Gas Model Gas Type to Convert to Nat Gas LPG Butane G47 232061 232060 232062 Town Gas N A ...

Страница 25: ......