Page 1: ...i INDOOR LOCATION TECHNOLOGY Setup Guide ...

Page 2: ...om date of purchase For further details regarding your Blackline warranty please refer to your terms and conditions of service More information and support visit http www blacklinesafety com 102128_R6 Intrinsically Safe Loner Beacon Model 102140 Sira 16ATEX2232 IECEx SIR YYYYX This equipment complies with EN 60079 0 2011 A11 2013 and EN 60079 11 2012 Ex ia IIC T4 Ga Ambient operating range 40 C to...

Page 3: ...RVIEW 1 GETTING STARTED 4 SELECT LOCATION BEACON PLACEMENT 5 INSTALL LOCATION BEACONS 6 PREPARE FLOOR PLANS 8 ADD LOCATION BEACON INFORMATION TO BLACKLINE LIVE 9 TEST LOCATION BEACON 10 CHANGING BATTERIES 11 SUPPORT 11 ...

Page 4: ... and around large buildings Combined with custom floor plans Blackline s Location Beacon precisely displays an employee s location on a Google map The end result is the fastest possible emergency response to your employee s exact location What are Location Beacons Location Beacons are compact wireless positioning transmitters Installed throughout facilities Location Beacon should be placed whereve...

Page 5: ...X MARKETING FIRMWARE SOFTWARE TESTING HARDWARE FRONT ENTRANCE SHIPPING ENTRANCE UNMONITORED TENANT BACK ENTRANCE SALES SOC CUSTOMER CARE ACCOUNTING MUSTER A MAIN FACILITY ENTRANCE MUSTER B MUSTER C 1 2 3 4 5 6 What are site plans Site plans are a great way to increase the level of detail for your entire property There may be key features that are not included within the standard Google Maps interf...

Page 6: ...nnot otherwise be determined using traditional GPS positioning technology When a Blackline device is within proximity of one or more beacons it reports the strongest signal to the Blackline Safety Network as a location update Within the Blackline Live portal the employees location is then mapped at the location of the reported beacon Location Beacon is certified intrinsically safe for locations wi...

Page 7: ...sy This guide will walk you through the five steps necessary to get your facility set up with Location Beacons 1 Select Location Beacon placement 2 Install Location Beacon 3 Prepare floor or site plans for Blackline Live 4 Add Location Beacon to Blackline Live 5 Test Location Beacon 6 Changing Batteries ...

Page 8: ...r placing Location Beacons near circulation pinch points like doorways catwalks or gates Obstructions made of metal or concrete will reduce signals more than wooden structures Beacons can be placed in elevators but should not be placed on moving vehicles or objects Beacons can be mounted on walls corners pillars or beams Smaller rooms up to 400 square feet normally require one beacon to have adequ...

Page 9: ...u will want to keep track of each beacon s Unit ID Installation location The following worksheet is available to help you organize this information See page 12 of this guide or download a digital copy from support BlacklineSafety com UNIT ID BEACON NAME PLACEMENT LOCATION POWER LEVEL LAYER LOCATION BEACON INFORMATION www BlacklineSafety com 0021 R5 2017 07 28 BUILDING NAME PHYSICAL ADDRESS 4 Mount...

Page 10: ...ould always be orientated upright upon installation 10 ft DO DO DON T DON T DON T DON T DON T 10 ft 10 ft After you have completed installation turn Location Beacon on by pressing the power status button The green status light will turn on when powered It will automatically turn off after a short period to conserve power but will continue to function when the green light is sleeping Pressing the w...

Page 11: ... or north is indicated on the file Use uncluttered legible maps Ensure files are labeled clearly Office 1 Office 2 Office 3 Office 4 Office 5 Reception Staff room Waiting area DO Office List Office 1 Ken Office 2 Jen Office 3 Carl Office 4 Jing Office 5 Bob Building 1 DON T Building 1 Building 1 Transparent background High resolution Accurate and current Oriented north up Floating text is outlined...

Page 12: ...2 From the main menu select beacon setup 3 Add the following information for each activated beacon Name of Location Beacon A friendly name that identifies the location of beacon i e Main Floor Entrance Site address The street address of the site where beacon is located Latitude and Longitude The actual location of where Location Beacon is installed The map pin can be dragged to automatically updat...

Page 13: ...phone 3 Wait five seconds to ensure your device has heard the new beacon 4 Select the monitoring device s map pin from the main map page 5 From the info box that appears ensure the beacon information seen corresponds with the beacon at the location 6 Repeat steps two through five for all installed beacons NOTE A Location Beacon signal tester device is available to provide an audible and visual ind...

Page 14: ...cklinesafety com CHANGING BATTERIES Location Beacon s two C cell batteries last up to five years at the highest transmit power setting When replacing beacon s batteries use only approved batteries to maintain intrinsic safety certification Screws C cell batteries Battery orientation guide underneath IMPORTANT Return Location Beacon to the same location that it was removed from to ensure the correc...

Page 15: ...12 UNIT ID BEACON NAME PLACEMENT LOCATION POWER LEVEL LAYER LOCATION BEACON INFORMATION www BlacklineSafety com 0021 R5 2017 07 28 BUILDING NAME PHYSICAL ADDRESS ...

Page 16: ...www BlacklineSafety com 0016 R9 2020 02 25 ...

Reviews: