background image

BLACK BOX

®

Extend Ethernet with full-duplex transmission  

up to 5.696 Mbps—more than four miles—over  

a pair of copper wires.

Complies with ITU-T Rec. G.991.2 G.shdsl.bis standards.  
Supports adaptive data rates from 4.608 Mbps to 192 kbps for SHDSL line.
Works at distances up to 22,500 feet over 26 AWG twisted-pair cable.
Has two RJ-45 connectors for 10BASE-T/100BASE-TX Ethernet ports  
for combining two separate Ethernet data streams over the same G.SHDSL link.
Includes a console port for network management configuration.

G.SHDSL Two-Wire Ethernet Network Extender

Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) •

FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 •

Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 •

Web site: www.blackbox.com   •   E-mail: [email protected]

Customer 

Support 

Information

 

December 2009 

LR0201A-KIT

Summary of Contents for LR0201A-KIT

Page 1: ... 100BASE TX Ethernet ports for combining two separate Ethernet data streams over the same G SHDSL link Includes a console port for network management configuration G SHDSL Two Wire Ethernet Network Extender Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Co...

Page 2: ... Tech Support at 724 746 5500 or go to blackbox com and click on Talk to Black Box You ll be live with one of our technical experts in less than 20 seconds Trademarks Used in this Manual Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners ...

Page 3: ...nt is operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to oper ate the equipment...

Page 4: ...inetes que impidan el flujo de aire por los orificios de ventilación 10 El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor 11 El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación o como se indique en el a...

Page 5: ... tested and found to comply with the protection requirements of European Emission Standard EN55022 EN61000 3 and the Generic European Immunity Standard EN55024 EMC EN55022 2003 CISPR 2 2002 Class A IEC61000 4 2 2001 4 KV CD 8 KV AD IEC61000 4 3 2002 3V m IEC61000 4 4 2001 1 KV power line 0 5 KV signal line ...

Page 6: ...plication 9 2 4 What s Included 9 2 5 LED Descriptions 9 2 6 Front and Back Panels 10 3 Installation 11 4 Console Configuration 12 4 1 Main Menu 13 4 2 Configuration Screen 14 4 2 1 DSL Mode Screen 14 4 2 2 DSL Speed Screen 15 4 2 3 Default Configuration Screen 16 4 3 Status Screen 17 4 3 1 System Information Screen 17 4 3 2 System Status Screen 18 ...

Page 7: ...3 4 miles 256 kbps 18 000 feet 3 4 miles 192 kbps 18 000 feet 3 4 miles 64 kbps 18 000 feet 3 4 miles Standards ITU T G 991 2 compliant TCPAM 16 Level Line Code IEEE 802 3 IEEE 802 3u EMI emission standard FCC Part 15 Class A CE Mark LAN Interface Autodetects for 10BASE T 100BASE TX and half full duplex Auto MDI X Connectors Each unit DSL 1 RJ 48 LAN 2 RJ 45 RS 232 console 1 DB9 F Indicators 7 LED...

Page 8: ... which will choose the best data rate for your link from 192 kbps to 4 608 Mbps The LR0201A KIT also pro vides a console port for users to configure the settings and to monitor the connection status The LR0201A KIT can be configured as either the central office master side or the remote slave side LR0201A KIT conforms to the ITU T Rec G 991 2 to meet G shdsl bis network requirements 2 2 Features I...

Page 9: ... G SHDSL Two Wire Ethernet Network Extenders 2 Power cords 2 CAT5e Ethernet cables This user s manual on CD ROM 2 5 LED Descriptions Table 2 1 Indicators LED Color Function POWER Green Lights when power is on TEST Green Lights when the device is in error Blinks when the device is in self test LOOP Green Lights when SHDSL loop connects successfully Blinks when SHDSL connection is in progress LAN 1 ...

Page 10: ...ox com Page 10 G SHDSL Two Wire Ethernet Network Extender 2 6 Front and Back Panels LED Indicators RS 232 Console Port Power Switch Power Input RJ 45 Connectors RJ 48 Connector Figure 2 2 Front panel Figure 2 3 Rear panel ...

Page 11: ...mechanical serviceability 4 Turn on the power switch Set one G SHDSL Two Wire Ethernet Network Extender as CO master site from console port and the other as remote slave site 5 Set the desired data rate for the SHDSL connection from the console port NOTE Both G SHDSL Two Wire Ethernet Network Extenders must have the same data rate settings 6 Both G SHDSL Two Wire Ethernet Network Extenders will au...

Page 12: ...nal Press the ESCAPE key and the main menu will be shown on the screen of the terminal The terminal operations can then start If you press tthe ESCAPE key and the terminal s screen does not display the COM port setting might be incorrect Choose the right COM port COM1 or COM2 on the computer and press the ESCAPE key again to make sure that the main menu appears on the terminal screen NOTE Set the ...

Page 13: ...igure 4 2 Welcome to G Shdsl Ethernet Network Extender User Interface Main Menu 1 Configuration 2 Status Select 1 2 ENTER select Figure 4 2 Main menu Figure 4 3 Pull down tree structure of the main menu The main menu s pull down tree structure is shown in Figure 4 3 DSL Mode DSL Speed Main Menu Default Configuration System Information System Status Configuration Status ...

Page 14: ...s DSL Mode DSL Speed and Default Configuration 4 2 1 DSL Mode Screen From the DSL Mode screen users can update DSL mode settings The DSL Mode settings initial values are read from DIP switches Configuration 1 DSL Mode 2 DSL Speed 3 Default Configuration Select 1 3 ENTER select DSL Mode CO RT 2P 1P STU C 1 Pair ARROW RIGHT ARROW LEFT type SPACE option ENTER select ESC quit Figure 4 4 Configuration ...

Page 15: ...bps 192 kbps 256 kbps 384 kbps 512 kbps 768 kbps 1152 kbps 1536 kbps 1544 kbps 2048 kbps 2304 kbps 3072 kbps 4608 kbps 5696 kbps and Adaptive speed Set both LR0201A KIT units to the same speed to establish a successful connection for 64 kbps 128 kbps 3072 kbps 4608 kbps 5696 kbps and Adaptive speed For the rate speed options between 192 kbps and 2304 kbps the remote slave site will follow the CO m...

Page 16: ...tings of the LR0201A KIT will go back to default settings The screen shown in Figure 4 7 indicates that the setting is finished Press ESC key to return to the previous screen The LR0201A KIT s default settings are STU C 1 Pair Adaptive speed Now the settings are STU C 1 Pair and Adaptive Speed Press ESC to quit ENTER quit Figure 4 7 Default Configuration screen ...

Page 17: ...irmware Version Indicates the firmware version in this unit Vendor Model Indicates this device s vendor model name Vendor Information Indicates the vendor s Web site address Status 1 System Information 2 System Status Select 1 2 ENTER select ESC quit System Information Firmware Version 2 5 Vendor Model LR0201A KIT Vendor Information www blackbox com ESC quit Figure 4 8 Status screen Figure 4 9 Sys...

Page 18: ...tion value in dB of Pair 2 The maximum value is 43 dB when the DSL distance is 22 500 ft 26 AWG Activation state of Pair 1 dB Indicates the DSL startup activation state of Pair 1 The value starts from 05 and gradually reaches the final value of 16 The value 16 is the DSL link up state value The general activation state sequence is 05 20 10 12 16 Activation state of Pair 2 dB Indicates the DSL star...

Page 19: ...ng from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by free live 24 7 Tech support available in 20 seconds or less Copyright 2009 All rights reserved Black Box Tech Support FREE Live 24 7 Tech support the way it should be Great tech support is just 20 seconds away at 724 746 5500 or blackbox com ...