FIVE YEAR LIMITED WARRANTY PROGRAM

This limited warranty program is the only one that applies to this product, and it sets forth all the

responsibilities of Vector Manufacturing, regarding this product. There is no other warranty, other than those

described herein.
This Vector Manufacturing product is warranted, to the original purchaser only, to be free of defects in

materials and workmanship for five years from the date of purchase without additional charge. The

warranty does not extend to subsequent purchasers or users. Manufacturer will not be responsible for any

amount of damage in excess of the retail purchase price of the product under any circumstances. Incidental

and consequential damages are specifically excluded from coverage under this warranty.
This product is not intended for commercial use. This warranty does not apply to accessories or damage to

units from misuse or incorrect installation. Misuse includes wiring or connecting to improper polarity power

sources.
RETURN/REPAIR POLICY: Defective products, other than accessories, may be returned postage prepaid to

manufacturer. Any defective product, other than accessories, that is returned to manufacturer within 30 days

of the date of purchase will be replaced free of charge. If such a product is returned more than 30 days

but less than five years from the purchase date, manufacturer will repair the unit or, at its option, replace it

free of charge.
If the unit is repaired, new or reconditioned replacement parts may be used, at manufacturer’s option. A

unit may be replaced with a new or reconditioned unit of the same or comparable design. The repaired or

replaced unit will then be warranted under the terms of the remainder of the warranty period. The customer

is responsible for the shipping charges on all returned items after 30 days. During the warranty period,

manufacturer will be responsible for the return shipping charges.
LIMITATIONS: This warranty does not cover accessories, bulbs, fuses and batteries, defects resulting from

normal wear and tear (including chips, scratches, abrasions, discoloration or fading due to usage or

exposure to sunlight), accidents, damage during shipping to our service facility, alterations, unauthorized

use or repair, neglect, misuse, abuse, failure to follow instructions for care and maintenance, fire, flood and

Acts of God.
If your problem is not covered by this warranty, call Technical Support at (800) 618-5178 for general

repair information and charges, if applicable. You may also contact us through our website at

www.vectormfg.com.
STATE LAW RIGHTS: This warranty gives you specific legal rights. Some states do not allow limitations on

how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages,

so the exclusions or limitations stated herein may not apply. This warranty gives the purchaser specific legal

rights; other rights, which vary from state to state, may apply.
TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT: Contact Technical Support by telephone, fax or

mail (see below). We suggest that you keep the original packaging in case you need to ship the unit. When

returning a product, include your name, address, phone number, dated sales receipt (or copy) and a

description of the reason for return and product serial number. After repairing or replacing the unit, we will

make every effort to return it to you within four weeks.
WARRANTY ACTIVATION: Please complete Warranty Activation Card and mail to Vector Manufacturing.

Enter “VEC1093DBD” as Model and “40/20/10/4 Amp 12 Volt Smart Automatic Battery Charger” as

Product Type. All Vector products must be registered within 30 days of purchase to activate this warranty.

Mail the completed registration form, along with a copy of the original sales receipt to:

ATTN.: CUSTOMER SERVICE 

4140 SW 30th Ave., Ft. Lauderdale, FL 33312 

• TOLL FREE: (800) 618-5178 • FAX: (954) 584-5556 •

WARRANTY IS NON-TRANSFERABLE AND NON-REFUNDABLE.

BD050205

VEC1093DBD

USER’S MANUAL 

& WARRANTY INFORMATION

IMPORTANT SAFETY INFORMATION, SAVE THESE INSTRUCTIONS

TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND
THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS IMPORTANT
INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS
PRODUCT. PLEASE RETAIN FOR FUTURE REFERENCE.

www.vectormfg.com

4140 S.W. 30th Ave., Ft. Lauderdale, FL 33312 U.S.

Toll Free: (800) 618-5178

© 2005 VECTOR MANUFACTURING

MADE IN CHINA

Fully Automatic Electronic

Smart Battery Charger

40/20/10/4 Amp Charge Rates

with 110 Amp Engine Start

VEC1093DBD_Manual_050205  5/5/05  6:32 PM  Page 12

Summary of Contents for Smart Battery Charger

Page 1: ...hipping to our service facility alterations unauthorized use or repair neglect misuse abuse failure to follow instructions for care and maintenance fire flood and Acts of God If your problem is not covered by this warranty call Technical Support at 800 618 5178 for general repair information and charges if applicable You may also contact us through our website at www vectormfg com STATE LAW RIGHTS...

Page 2: ...NG NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY 2 To reduce risk of battery explosion follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you intend to use in vicinity of battery Review cautionary markings on these products...

Page 3: ...ing 9 See operating instructions for length of charge information Follow these steps when the battery has been removed from a vehicle A spark near the battery may cause an explosion To reduce risk of a spark near the battery 1 Check polarity of battery posts The POSITIVE post marked POS P usually has a larger diameter than the NEGATIVE battery post marked NEG N 2 Attach a 24 inch minimum length 6 ...

Page 4: ... possible charge at a constant safe predetermined voltage During this phase the charging voltage remains constant while the actual charging current is reduced to allow for the maximum proper internal chemical energy transfer At the end of Stage 2 the charger will automatically move into Stage 3 charge mode Stage Three Top Off Charge voltage is automatically maintained and reduced to a predetermine...

Page 5: ...ore advances charging rate to 20 amps and again to 40 amps Pressing the button again will turn OFF the charger output and the Display will show 000 This selection and actual battery charge rate are monitored by the microprocessor and the unit will stop charging if the selected rate is too fast or too slow for battery size or condition As the battery nears full charge capacity the unit s output wil...

Page 6: ...ate charge most of the lead sulfate is dissolved and the plates are free of this insulation If a battery remains in a discharged condition over a longer period of time the lead sulfate changes to a hard crystalline form making a full charge difficult to achieve Reconditioning may save a sulfated battery 6 Pressing the 4 10 20 40 AMP button repeatedly advances to standby mode the unit sounds a beep...

Page 7: ...ONDITION Mode Observe the Digital Display for any codes This initial charge will check the battery for shorted cells F01 open cells F03 or battery too low to accept a charge F02 and to ensure the battery can take a charge If code F03 is displayed change to the BATTERY RECONDITION MODE Remove or disconnect the vehicle s battery when reconditioning 1 Make sure the charger is in initiation state with...

Page 8: ...oning and equalizing we recommend taking your battery to a certified automotive service center for evaluation F04 Overtime Condition Appears when charging time exceeds 18 hours You may be using a charge current rate too low for a large battery Select higher charge rate to charge the battery F05 Overheated Condition The ventilation grill that prevents the air from flowing in and out of the charger ...