User’s Manual

ELSA

Blood Glucose Monitoring System

101-3GM111-0D0 EN          

Rev

. Da

te: 2021-06

Emergo Europe

Prinsessegracht 20
2514 AP The Hague
The Netherlands
Email: [email protected]

BIONIME CORPORATION

No. 100, Sec. 2, Daqing St., South Dist.,
Taichung City 40242, Taiwan
Tel:   +886 4 2369 2388
Fax:  +886 4 2261 7586
Email: [email protected]
http://www.bionime.com
Made in Taiwan 

Содержание Rightest Elsa

Страница 1: ...1 06 Emergo Europe Prinsessegracht 20 2514 AP The Hague The Netherlands Email EmergoVigilance ul com BIONIME CORPORATION No 100 Sec 2 Daqing St South Dist Taichung City 40242 Taiwan Tel 886 4 2369 238...

Страница 2: ......

Страница 3: ...HTEST ELSA Blood Glucose Monitoring System is accurate and easy to use making it your reliable diabetes management assistant The RIGHTEST ELSA Blood Glucose Monitoring System is manufactured and suppo...

Страница 4: ...ovided and conduct all of the recommended tests including the quality control test see page 33 Please perform the quality control test regularly to make sure test results are accurate The RIGHTEST ELS...

Страница 5: ...e Time Date Volume and Test Unit Turning the Meter On Off Testing Procedure Performing a Blood Glucose Test Alternative Site Testing AST Viewing Window Appearance 8 10 14 16 18 22 23 27 29 Quality Con...

Страница 6: ...lucose Monitoring System 1 RIGHTEST ELSA Blood Glucose Meter with 1 CR2032 battery installed 2 Instruction documents Getting Started and User s Manual includes Log Book Warranty Card Emergency Card 3...

Страница 7: ...Port Insert test strips here Display Window Shows your test result messages and other information Main Button Used to operate the meter Please see the following sections for further details Battery Co...

Страница 8: ...ay need replacing Prompt to apply a blood sample Test strip Appears if an error has occurred Current Date in Time mode or Test Date in Memory mode Indicates temperature is too high for testing Time in...

Страница 9: ...st strip vial immediately after taking out a test strip Do not reuse test strips Test strip can be only used once Do not use expired test strips Every time when you open a new vial of test strips plea...

Страница 10: ...p Your Meter Setting the Time Volume and Date Test results are still stored in the memory 3 Slide the battery cover back on until it snaps into place 2 Install the battery Make sure the battery is ins...

Страница 11: ...main button to turn on the meter Press and hold the main button for 7 seconds You will hear a beep if volume is turned on and be taken to the Settings mode The display screen will show the settings S...

Страница 12: ...its setting NOTE If you do not adjust the settings for 2 minutes the meter will exit the Settings mode and power off The default units of your RIGHTEST Meter are set according to your region Setting U...

Страница 13: ...on Depth adjustable cap 1 Hold the depth adjustable cap with one hand and hold the hub with the other Bend the device and apply pressure at the join until it gently pops open 2 Pull apart both ends to...

Страница 14: ...test strip port The meter confirms a strip has been inserted with a beep if the volume is turned on 8 9 10 11 A blood drop symbol appears and is accompanied by a further beep if volume is turned on A...

Страница 15: ...nted on the label whichever comes first Always keep the metal contact points of the test strip entry point clean If any dust or impurities are present clean with a small soft brush otherwise the meter...

Страница 16: ...brate continuous glucose monitors CGMs Viewing Window Appearance Make sure your blood sample covers the whole area of the Viewing Window An insufficient blood sample will result in an error message Er...

Страница 17: ...est results and you are sure that you have followed all the instructions in this manual contact your healthcare professional immediately Quality Control Test Use RIGHTEST Control Solution to test the...

Страница 18: ...e Quality Control Test If your Control Solution test results are still out of range do not use the system to test your blood glucose Contact Bionime customer service Example of Expiration Date 1 Take...

Страница 19: ...the validity period after opening and the storage environment please refer to RIGHTEST Control Solution GC570 Insert 34 Recalling Results and Viewing the Average Result The RIGHTEST Meter is able to...

Страница 20: ...test press the main button to enter the Memory screen and review the result PRECAUTION You must set the time and date to activate the average function and results control solution results and test res...

Страница 21: ...sible contaminates from surfaces Only the disinfecting procedure can eliminate non visible pathogens If the meter is being operated by a second person who is providing testing assistance to the user t...

Страница 22: ...41 2 1 3 2 min Clean and disinfect the lancing device weekly To clean the lancing device 1 Thoroughly wipe the entire surface of the lancing device with disinfecting wipes to clean any dirt dust blood...

Страница 23: ...roubleshooting Error Messages and Troubleshooting Battery Error 1 blinks when the battery power is low Please change the meter battery soon You can still do a test 2 and blink when the battery power i...

Страница 24: ...5 minutes and insert the batteries as described in Activating the Meter and Changing the Battery on page 16 17 The meter should now be working normally If not please contact Bionime customer service S...

Страница 25: ...oxygen therapy may yield falsely low results These test strips should not be used with meters to test critically ill patients or neonates The blood glucose test result may be affected by high blood co...

Страница 26: ...at your RIGHTEST Meter will be free from defects in materials and workmanship for five years from the date of purchase This warranty does not apply to the performance of a RIGHTEST Meter that has been...