background image

900 Quadrant Steam 

Shower Cabin with 6 Body Jets

PLEASE READ THE GUIDE BEFORE COMMENCING INSTALLATION

Please retain this document for future reference

Multiple person assembly

BUY IT DIRECT

Lowfields Way

Elland

Hx5 9DA

This

 

product

 

is

 

IPX4

 

rated

and

 

so

 

no

 

part

 

of

 

the

 

installation

 

is

 

allowed

 

to

 

be

 

within

 

bathroom

 

Zones

 

0

 

or

 

1

Installation

 

is

 

permitted

 

within

 

Zone

 

2

and

 

outside

 

of

 

the

 

bathroom

 

zones

 

as

 

long

 

as

 

it

 

is

 

not

 

in

 

a

 

position

 

where

 

it

 

is

 

likely

 

to

 

be

 

sprayed

 

with

 

water

.

 Zone 0: 

 

The interior of the bathtub or shower basin.

 Zone 1: 

 The area around the bathtub or shower 

 

basin

 up to a height of 2.25m above the floor

 Zone 2:  

The area stretching to 0.6m outside the bath 

 

or 

shower and above the bath or shower if over 2.25m

Summary of Contents for 900 Quadrant Steam

Page 1: ...the installation is allowed to be within bathroom Zones 0 or 1 Installation is permitted within Zone 2 and outside of the bathroom zones as long as it is not in a position where it is likely to be sp...

Page 2: ...e and remain hot for a period after use therefore contact with either can cause injury do not touch until fully cooled After use always turn off the unit at the switch Any maintenance should only be c...

Page 3: ...e tray is level If levelling is required adjust the legs on the tray Check the tray using a spirit level Once the tray is level tighten the securing nuts on the legs After levelling connect the pre fi...

Page 4: ...l 2 2 Hold the rail 1 to the front face of the chrome profile 2 5 Ensure the fin on the seal faces inside the enclosure 3 From inside the profile connect the screws A and tighten into rail 6 Fit the g...

Page 5: ...e end of the touching surfaces Do not seal on the inside central panel 5 10 Push the back panels 4A and 4B to the central panel 5 after being sealed and align correctly 11 Secure together using the nu...

Page 6: ...ate V onto the back corner of the tray Drill should not be on hammer setting 14 Align the steam generator to the steel plate once steam generator Hold this frame and secure into position using the fix...

Page 7: ...frame using a 3mm drill bit back panels and to the tray Remove the assembly Failure to seal in this way may allow water to escape through the touching surfaces and to the outside of the enclosure Ali...

Page 8: ...21 Secure the steam generator frame to the steel plate V using fixings provided nuts and bolts G 20 Connect flexi tube from mixer to shower head connection 22 Insert steam generator hose through centr...

Page 9: ...the back and side edges where the frame must be connected to the left inlet failure to do this will meets the tray ensuring not block the drainage slots cause issues with the thermostat function 25 W...

Page 10: ...ose facing down 37 Hook the door onto the top rail push the door towards the 33 Attach fixings for shelf to right hand back panel and secure bottom rail then press down on the bottom roller to hook th...

Page 11: ...f the cabin roof as shown below Cable Connections 45 The radio aerial strip should be un wound and attached to the 41 All connections need to be made before moving the enclosure roof of the cabin or w...

Page 12: ...d symbols Control Panel Function Please note Telephone function requires connection to your landline cable connector CD function requires connection to a CD player with the CD player outside the enclo...

Page 13: ...this model CD Function Press the FM CD button until the CD symbol is displayed on Fan the screen Press the fan button to activate the extraction fan flashing You will need to connect an external CD pl...

Page 14: ...cks Check water supply is reaching the steam tank Check cable connections When the set steam time has been reached the steam will Check if inlet valve filter on the steam tank is blocked turn off Solu...

Page 15: ...position to allow water to drain On the handle unscrew the handle peg Fig 1 Using a hex key loosen the grub screw inside the handle Fig 2 Pull off the handle Using a spanner remove the brass retainer...

Page 16: ...y debris or limescale TURN OFF WATER SUPPLY Turn the diverter handle to an open position to allow water to drain Turn temp handle to the 38c stop position and remove the handle cap Fig 1 Using a hex k...

Page 17: ...wer Hose Flow control diverter Door runners Seals Failure to seal correctly will invalidate your guarantee Reported damage after installation will not be covered by your guarantee Maintenance For some...

Page 18: ...separated and disposed of in an environmentally friendly manner Contact your local disposal site to confirm SEPT 18 V6BB Product Specification Working Pressure 1 5 to 4 bar Pressure MUST be balanced D...

Reviews:

Related manuals for 900 Quadrant Steam