Summary of Contents for 1464T

Page 1: ...1464T MODE D EMPLOI GEBRAUCHSANWEISUNG INSTRUCCIONES GEBRUIKSAANWIJZING INSTRUKCJA OBSŁUGI ISTRUZIONI PER L USO INSTRUCTIONS FOR USE INSTRUÇÕES DE USO HASZNÁLATI ÚTMUTATÓ I D NL EN E PL F PT HU ...

Page 2: ...cted data so that they can later be sent to a computer Specifications 80 bar sensor precision ratiometric 1 FS 0º 50º Power supply rechargeable battery LiPo 3 7V 1000mAh Battery charge via USB connector Display colour TFT 5 480x272 pixels tactile Connectivity USB Windows Updatable software V Observations The display is a tactile resistive device some precision is required so that it can respond Yo...

Page 3: ...he required option is displayed press the relevant button to select it When using the tester for the first time select first the Configuration option and then the required options When the configuration screen is exited it will be saved automatically As you can see in the picture below you can configure the language the brightness of the screen the volume of the loudspeaker the unit of measurement...

Page 4: ...e relevant instructions What is the common rail system What is the common rail system The common rail system is one of the most advanced diesel fuel injection systems based on the fuel injected directly into the cylinder direct injection at high pressure 300 2000 bar One of the great advantages of this new system lies in the fact that the nozzles are controlled electronically so an electronic unit...

Page 5: ...ested The low pressure circuit test is a three step test Test n 1 Description pressure test at high pressure pump inlet Correct value 2 5 bar Results of test n 1 Correct pressure 2 5 bar Go to test n 2 Significantly higher pressure faulty regulator Significantly lower pressure go to test n 2 Test n 2 Description pressure between low pressure pump and filter Correct value 2 5 bar Results of test n ...

Page 6: ...can be saved when needed by pressing the Save key The term REC will be shown in the upper part of the display Press Save again to store the value The data thus saved can later be sent to a computer via USB connection 80 bar manometer This instrument can measure pressures up to 80 bar like a normal manometer The pressure and maximum reading values will be shown on the display The latter can be rese...

Page 7: ...avoiding possible negative effects for the environment and people s health and facilitates the recycling of the materials the equipment is made of Illegal disposal of this product on part of the user will give way to the application of such administrative fines as referred to in Italian Legislative Decree n 22 1997 article 50 and following articles of Italian Legislative Decree n 22 1997 WARRANTY ...