background image

1/6

09/2015

Blind insert comfort

Blind insert comfort

Order no.: 8522 11 0x

Operating instructions

1.  Safety instructions

Electrical equipment may only be installed and assembled by a qualified electrician in 

accordance with the relevant installation standards, guidelines, regulations, directives, 

safety and accident prevention regulations of the country.
Failure to comply with these instructions may result in damage to the device, fire or other 

hazards.
Hazard due to electric shock. Disconnect before working on the device. Take into 

account all circuit breakers that supply dangerous voltages to the device.
Hazard due to electric shock. The device is not suited for safe disconnection of the 

mains supply.
Hazard due to electric shock. Do not operate device without application module.
If several drives should be connected in parallel to one output, it is mandatory to observe 

the manufacturer's data; use a cut-off relay where required. Motors could be destroyed.
Use blind drives with mechanical or electrical final position switches only. Check final 

position switches for correct adjustment. Observe motor manufacturer's data. The device 

can be damaged.
Use blind push-buttons only for extension unit operation. The use of blind push-buttons 

can cause malfunctions.
Risk of injury. Use the device to control blind and shutter drives or awnings only. Do not 

switch any other loads.
Observe the motor manufacturer's data regarding change-over time and max. 

switch-on time (ED).
Do not lay control lines in parallel to the motor lines (danger of coupling).
These instructions are an integral component of the product and must be retained by the 

end user.

Summary of Contents for 8522 11 0 Series

Page 1: ... electric shock Do not operate device without application module If several drives should be connected in parallel to one output it is mandatory to observe the manufacturer s data use a cut off relay where required Motors could be destroyed Use blind drives with mechanical or electrical final position switches only Check final position switches for correct adjustment Observe motor manufacturer s d...

Page 2: ...buttons for blinds blind inserts key push buttons for blinds Only suitable for use in indoor areas with no drip and no spray water Installation into wall box according to DIN 49073 Operate with suitable application module see Chapter 6 2 Accessories Product characteristics 2 mechanically and electrically mutually locked relay contacts 4 Operation These instructions describe the installation of the...

Page 3: ...protection Circuit shutter insert according to circuiting diagram Figure 2 Mount shutter insert in wall box recommended deep box The connecting terminals must be at the bottom Attach frame and application module see instructions for application module Control by sensors Sensors such as wind precipitation sensors are used e g to protect awnings from damage If a threshold is exceeded on the sensors ...

Page 4: ...ension unit Individual control with push button for blind extension unit according to circuiting diagram 503520 Individual control with key push button for shutter extension unit Circuit individual control with key push button for shutter extension unit according to circui ting diagram ...

Page 5: ...rt Master and group control Circuit master and group control according to circuiting diagram Master control under application of various RCCBs Circuit master control under application of various RCCBs according to circuiting diagram ...

Page 6: ...m Mounting orientation connecting terminals downwards Housing installation depth 22 mm Claw guide installation depth 32 mm 6 2 Accessories Push button for blinds order no 8524 11 xx Blind time switch order no 8574 11 xx Radio push button for shutters quicklink order no 8524 51 xx Radio shutter timer quicklink order no 8574 51 xx 6 3 Warranty We reserve the right to make technical and formal change...

Reviews: