background image

Installation RED25

Release 01 02/2015

Technical support

https://hirschmann-support.belden.eu.com

User Manual

Installation
Redundancy Switch
RED25

Summary of Contents for Hirschmann RED25 Series

Page 1: ...Installation RED25 Release 01 02 2015 Technical support https hirschmann support belden eu com User Manual Installation Redundancy Switch RED25 ...

Page 2: ...ce features described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s knowledge Hirschmann reserves the right to change the contents of this document without prior notice Hirschmann can give no guarantee in respect of the correctness or accuracy of the inf...

Page 3: ...ort state 19 1 7 Management interfaces 19 1 7 1 V 24 interface external management 19 1 7 2 USB interface 20 1 8 Signal contact 21 2 Installation 22 2 1 Checking the package contents 22 2 2 Installing and grounding the device 22 2 2 1 Installing the device onto the DIN rail 23 2 2 2 Grounding the device 23 2 3 Installing an SFP transceiver optional 23 2 4 Connecting the power supply and signal lin...

Page 4: ...4 Installation RED25 Release 01 02 2015 5 Maintenance and service 29 6 Disassembly 30 6 1 Removing the device 30 6 2 Removing an SFP transceiver optional 31 7 Technical data 32 A Further Support 39 ...

Page 5: ...experience make up their qualifications This is the prerequisite for grounding and labeling circuits devices and systems in accordance with current standards in safety technology Qualified personnel are aware of the dangers that exist in their work Qualified personnel are familiar with appropriate measures against these hazards in order to reduce the risk for themselves and others Qualified person...

Page 6: ...electrical conductors All of the following requirements are fulfilled The voltage connected meets the requirements for a safety extra low voltage SELV as per IEC EN 60950 1 The connected voltage is limited by a current limitation device or a fuse Observe the electrical threshold values for the signal contact See General technical data on page 32 Table 2 Requirements for connecting the signal conta...

Page 7: ...fety extra low voltage SELV as per IEC EN 60950 1 Supply with DC voltage A fuse suitable for DC voltage is located in the plus conductor of the power supply The minus conductor is on ground potential Otherwise a fuse is also located in the minus conductor Regarding the properties of this fuse See General technical data on page 32 Supply with AC voltage A fuse is located in the outer conductor of t...

Page 8: ...requirements as per NEC Class 2 Alternative 3 All of the following requirements are fulfilled The voltage supply meets the requirements for a safety extra low voltage SELV as per IEC EN 60950 1 Supply with DC voltage A fuse suitable for DC voltage is located at both voltage inputs in the plus conductor of the power supply The minus conductor is on ground potential at both voltage inputs Otherwise ...

Page 9: ...ive of the European Parliament and the council for standardizing the regulations of member states with regard to electromagnetic compati bility In accordance with the above named EU directive s the EU conformity declaration will be at the disposal of the relevant authorities at the following address Hirschmann Automation and Control GmbH Stuttgarter Str 45 51 72654 Neckartenzlingen Germany Tel 49 ...

Page 10: ...tal device in line with part 15 of the FCC regula tions These requirements are designed to provide sufficient protection against interference when the device is being used in a business environment The device creates and uses high frequencies and can also radiate these frequencies If it is not installed and used in accordance with this oper ating manual it can cause radio transmission interference...

Page 11: ...r manual Reference manual for the graphical user interface Command Line Interface reference manual User Manual Industry Protocols The Industrial HiVision network management software provides you with additional options for smooth configuration and monitoring ActiveX control for SCADA integration Auto topology discovery Browser interface Client server structure Event handling Event log Simultaneous...

Page 12: ... various media to connect to the terminal devices and other network components Multimode optical fiber Singlemode optical fiber Twisted pair cable The redundancy concept allows the network to be reconfigured quickly There are convenient options for managing the device Administer your devices via a Web browser SSH Telnet HiDiscovery Software for putting the device into operation network management ...

Page 13: ...nections 14 15 Configuration of the other ports TT 2 RJ45 socket for 10 100 Mbit s twisted pair connections 16 17 Temperature range S Standard 0 C 60 C 32 F 140 F T Extended 40 C 60 C E Extended with conformal coating 40 C 60 C 18 19 Supply voltage DD 2 voltage inputs for redundant power supply Rated voltage range DC 12 V 48 V Nominal voltage AC 24 V 20 21 Certificates and decla rations Note You w...

Page 14: ...ix version 00 XX Current bugfix version Application case Certificates and declarations Characteristic value Y9 Z9 Standard applications CE X X EN 60950 1 X X EN 61131 2 X X FCC X X UL 61010 1 UL 61010 2 210 X Table 5 Assignment application cases certificates and declarations character istic values Item Characteristic Charac teristic value Description Table 4 Device name and product code ...

Page 15: ...45 socket for 10 100 Mbit s twisted pair connections 16 S 17 Temperature range Standard 0 C 60 C 32 F 140 F DD 18 19 Supply voltage 2 voltage inputs for redundant power supply Rated voltage range DC 12 V 48 V Nominal voltage AC 24 V Y9 20 21 Certificates and declara tions Standard applications CE EN 60950 1 EN 61131 2 FCC UL 61010 1 UL 61010 2 210 HM 22 23 Customer specific version Hirschmann Fast...

Page 16: ...tatus 4 USB interface 5 V 24 interface 6 Other ports 2 RJ45 socket for 10 100 Mbit s twisted pair connections 7 Uplink ports alternatively depending on device variant Characteristic value 2Z6 2 SFP slot for 100 Mbit s F O connections Characteristic value 2T1 2 RJ45 socket for 10 100 Mbit s twisted pair connections 8 Grounding screw Table 7 Front view on the left Device variants RED25 04002T1TT DD ...

Page 17: ...ity 10 Mbit s half duplex mode 10 Mbit s full duplex mode 100 Mbit s half duplex mode 100 Mbit s full duplex mode Delivery state autonegotiation active The socket housing is electrically connected with the front panel The pin assignment corresponds to MDI X 9 Locking gate for removing the device 10 MAC address of device label 11 Label area for IP address of device Pin Function 1 RD Receive path 2 ...

Page 18: ...age None Supply voltage is too low Yellow Lights up Device variants with redundant power supply Supply voltage 1 or 2 is on flashes4 times a period Software update is running Maintain the power supply Green Lights up Device variants with redundant power supply Supply voltages 1 and 2 are on Device variants with single power supply Supply voltage is on Status Device Status None Device is starting a...

Page 19: ...ow Lights up No redundancy exists ACA Storage medium ACA21 USB ACA22 USB None ACA storage medium not connected Green Lights up ACA storage medium connected Flashes 3 times a period Device writes to reads from the storage medium Yellow Lights up ACA storage medium inoperative Display Color Activity Meaning Link status None Device detects an invalid or missing link Green Lights up Device detects a v...

Page 20: ...erface offers you the ability to connect the storage medium AutoCon figuration AdapterACA21 USB ACA22 USB This storage medium is used for saving loading the configuration and diagnostic functions and for loading the software The USB interface has the following properties Supports the USB master mode Supports USB 1 1 data rate max 12 MBit s Connectors type A Supplies current of max 500 mA Voltage n...

Page 21: ...ess the device signals events such as a line interruption When an event occurs the device opens the relay contact and interrupts the closed circuit The management setting specifies which events switch a contact You can also use the management to switch the signal contact manually and thus control external devices For further information see Connecting the power supply and signal lines on page 24 ...

Page 22: ...Connecting the power supply and signal lines Operating the device Connecting data cables Filling out the inscription label Making basic settings 2 1 Checking the package contents Proceed as follows Check whether the package includes all items named in the section Scope of delivery on page 37 Check the individual parts for transport damage 2 2 Installing and grounding the device WARNING FIRE HAZARD...

Page 23: ...ight and left sides of the device To mount the device onto a horizontally mounted 35 mm DIN rail according to DIN EN 60715 proceed as follows Slide the upper snap in guide of the device into the DIN rail Press the media module downwards onto the clip in bar Snap in the device 2 2 2 Grounding the device The device has a functional ground connection Ground the device via the ground screw 2 3 Install...

Page 24: ...minals for electric conductors Do not touch the connection terminals Before connecting the electrical conductors always verify that all of the requirements listed are fulfilled See Requirements for connecting electrical conductors on page 6 Failure to follow these instructions can result in death serious injury or equipment damage 1 Power supply connection 1 1a 24 V 1b 0 V 2 Connection for the sig...

Page 25: ...e the power connector from the device Connect the wires according to the pin assignment on the device with the clamps Fasten the wires connected by tightening the terminal screws Signal contact optional Connect the wires according to the pin assignment on the device with the clamps Fasten the wires connected by tightening the terminal screws Type of the voltages that can be connected Specification...

Page 26: ...tical data cables for the data transmission between the buildings When using copper cables provide a sufficient separation between the power supply cables and the data cables Ideally install the cables in separate cable channels Use shielded cables SF UTP cables as per ISO IEC 11801 2002 Connect the data cables according to your requirements For further information see Ethernet ports on page 17 2 ...

Page 27: ...y via V 24 connection Entry with the aid of the HiDiscovery logs on the applications HiDiscovery or Industrial HiVision Configuration via BOOTP Configuration via DHCP Option 82 ACA21 USB ACA22 USB Further information on the basic settings of the device can be found in the user manual on the CD DVD Default settings IP address The device looks for the IP address using DHCP Management password user p...

Page 28: ...5 cm from the device It depends on the installation conditions of the device e g the distance from other devices or other objects and the output of neigh boring devices The temperature displayed in the CLI and the GUI is the internal temperature of the device It is higher than the ambient air temperature The maximum internal temperature of the device named in the technical data is a guideline that...

Page 29: ...itching function depending on the frequency of the switching operations Hirschmann are continually working on improving and developing their software Check regularly whether there is an updated version of the soft ware that provides you with additional benefits You find information and software downloads on the Hirschmann product pages on the Internet www hirschmann com Depending on the degree of ...

Page 30: ... supply voltage Disconnect the terminal blocks Disconnect the grounding To remove the device from the DIN rail you proceed as follows Insert a screwdriver horizontally below the housing into the locking gate Pull the locking gate down without tilting the screwdriver Lift the bottom of the device away from the DIN rail ...

Page 31: ... RED25 Release 01 02 2015 31 6 2 Removing an SFP transceiver optional Proceed as follows Pull the SFP transceiver out of the socket by means of the opened lock Close the SFP transceiver with the protective cap 1 2 ...

Page 32: ... A Nominal value at 24 V 1 A 2 A Nominal value at 12 V 1 A 2 5 A Characteristic slow blow Back up fuse when 1 voltage input used Nominal value at 48 V 1 A 2 A Nominal value at 24 V 1 A 4 A Nominal value at 12 V 1 A 5 A Characteristic slow blow Peak inrush current 14 A Permitted peak values for the input voltage with respect to the ground potential of the housing 60 V Climatic condi tions during op...

Page 33: ...g voltage max 60 V DC Relevant for North America max 30 V DC resistive load Pollution degree 2 Protection classes Laser protection Class 1 in compliance with IEC 60825 1 Degree of protection IP20 a Reduction of the maximum permitted ambient air temperature under specific conditions b Temperature of the ambient air at a distance of 2 inches 5 cm from the device c Use SFP transceivers with the EEC e...

Page 34: ...34 Installation RED25 Release 01 02 2015 Dimension drawings Figure 2 Dimensions 46 9 3 105 3 130 mm inch 1 81 4 15 0 37 5 12 ...

Page 35: ...ommunication connections Class A EN 61000 6 4 Telecommunication connections Fulfilled EMC interference immu nity Electrostatic discharge EN 61000 4 2 IEEE C37 90 3 Contact discharge 4 kV EN 61000 4 2 IEEE C37 90 3 Air discharge 8 kV Electromagnetic field EN 61000 4 3 80 MHz 3000 MHz 10 V m Fast transients burst EN 61000 4 4 IEEE C37 90 1 AC DC supply connection 2 kV EN 61000 4 4 IEEE C37 90 1 Data...

Page 36: ...tion BLP dispersion MM LC MM 1310 nm 50 125 µm 0 8 dB 0 5 km 1 0 dB km 800 MHz km MM LC MM 1310 nm 62 5 125 µm 0 11 dB 0 4 km 1 0 dB km 500 MHz km SM LC SM 1310 nm 9 125 µm 0 13 dB 0 25 km 0 4 dB km 3 5 ps nm km SM LC SM 1310 nm 9 125 µm 10 29 dB 25 65 km 0 4 dB km 3 5 ps nm km LH LC SM 1550 nm 9 125 µm 10 29 dB 47 104 km 0 25 dB km 19 ps nm km LH LC SM 1550 nm 9 125 µm 10 29 dB 55 140 km 0 18 dB ...

Page 37: ...lock 50 pcs 943 845 013 Network management software Industrial HiVision 943 156 xxx Dust protection cap 50 pieces for RJ 45 sockets 943 936 001 Dust protection cap 25 pieces for SFP slot 943 942 001 Rail Power Supply RPS 30 943 662 003 Rail Power Supply RPS 80 EEC 943 662 080 Rail Power Supply RPS 120 EEC 943 662 120 Fast Ethernet SFP transceiver Order number M FAST SFP TX RJ45 942 098 001 M FAST ...

Page 38: ...gy equipment Radio disturbance character istics Limits and methods of measurement EN 60950 1 Information technology equipment Safety Part 1 General requirements EN 61000 6 2 Electromagnetic compatibility EMC Part 6 2 Generic stan dards Immunity for industrial environments EN 61131 2 Programmable controllers Part 2 Equipment requirements and tests FCC 47 CFR Part 15 Code of Federal Regulations IEEE...

Page 39: ...E mail inet ap belden com Hirschmann Competence Center The Hirschmann Competence Center is ahead of its competitors Consulting incorporates comprehensive technical advice from system evaluation through network planning to project planning Training offers you an introduction to the basics product briefing and user training with certification The current technology and product training courses can b...

Page 40: ......

Reviews: