Please read and notice the detailed  

”Manual F/O Fieldbus Repeater OZD Profi 12M … PRO“.

Use the fax form on page 6 of this leaflet to order a free copy of this manual (Order No. 039 690-001).

General Safety Instructions

This device is electrically operated. Adhere strictly to the safety requirements relating to voltages applied to the device
as described in the operating instructions!

Make sure that the electrical installation meets local or nationally applicable safety regulations.

Warning!

Failure to observe the information given in the warnings could result in serious injury and/or major damage. 
Only personnel that have received appropriate training should operate this device or work in its immediate vicinity.
The personnel must be fully familiar with all of the warnings and maintenance measures in these operating
 instructions.
Correct transport, storage, and assembly as well as careful operation and maintenance are essential in ensuring
safe and reliable operation of this device.
Never start operation with damaged components!

Warning!

Any work that may have to be per formed on the electrical installation should be performed by fully  qualified
 technicians only.

Warning!

LED- or LASER components according to IEC 60825-1 (2007):
CLASS 1 LASER PRODUCT.
LIGHT EMITTING DIODE - CLASS 1LED PRODUCT.

Certified Usage

Please observe the following:

Warning!

The device may only be employed for the purposes described in the catalog and technical description, and only in
conjunction with external devices and components recommended or approved by Hirschmann. The product can
only be operated correctly and safely if it is transported, stored, installed and assembled properly and correctly.
 Furthermore, it must be operated and serviced carefully.

Safety Guidelines Power Supply

Switch the basic devices on only when the housing is closed.

Warning!

The devices may only be connected to the supply voltage shown on the type plate. The devices are designed for
 operation with a safety extra-low  voltage.Thus, they may only be connected to the supply voltage connec tions and
to the signal contact with PELV circuits or  alternatively SELV  circuits with the  voltage restrictions in accordance with
IEC/EN 60950-1.

Relevant for North America:

The subject unit is to be suppplied by a Class 2 power source complying with the requirements of the National Electrical
Code, table 11(b). If power is redundant supplied (two individual power sources) the power sources together should
comply with the requirements of the National Electrical Code, table 11(b).

Use 60/75 °C or 90 °C copper(Cu) wire/conductor only.

Startup Information

OZD Profi 12M … PRO

Hirschmann. Simply a good Connection.

de
en

fr

Summary of Contents for Hirschmann OZD Profi 12M Pro Series

Page 1: ...07 CLASS 1 LASER PRODUCT LIGHT EMITTING DIODE CLASS 1LED PRODUCT Certified Usage Please observe the following Warning The device may only be employed for the purposes described in the catalog and technical description and only in conjunction with external devices and components recommended or approved by Hirschmann The product can only be operated correctly and safely if it is transported stored i...

Page 2: ... Tel 49 0 1805 14 1538 E Mail HAC Support Belden com FCC RULES This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limit...

Page 3: ...the hazardous location temperature code When combining products within a system the most adverse temperature code lowest T number may be used to help determine the overall temperature code of the system Combinations of equipment in your system are subject to investigation by the local Authority Having Jurisdiction at the time of installation 䊳 The peripheral equipment must be suitable for the loca...

Page 4: ...orrect assignment can result in destruction of the repeater Limit values of relay contact Max switching voltage 60 V DC 42 V AC Max switching current 1 0 A Max switching capacity 30 W resistive load 䊳 The voltage connected to the relay must correspond to a safety extra low voltage SELV to IEC EN 60 950 and must comply with NEC Class 2 regulations as stipulated by UL CSA Analog Voltage Outputs The ...

Page 5: ...accordance with EN60079 15 taking into account the environmental conditions under which the equipment will be used 䊳 When the temperature under rated conditions exceeds 70 C at the cable or conduit entry point or 80 C at the branching point of the conductors the temperature specification of the selected cable shall be in compliance with the actual measured temperature values 䊳 Installation additio...

Page 6: ...6 ...

Page 7: ...ules 䡺 OZD Profi 12M P11 PRO 䡺 OZD Profi 12M G11 PRO 䡺 OZD Profi 12M G11 1300 PRO 䡺 OZD Profi 12M P12 PRO 䡺 OZD Profi 12M G12 PRO 䡺 OZD Profi 12M G12 1300 PRO 䡺 OZD Profi 12M G12 EEC PRO 䡺 OZD Profi 12M G12 1300 EEC PRO We apply the following network topology 䡺 Line topology with optical cable monitoring 䡺 Star 䡺 Line topology without optical cable monitoring 䡺 Redundant optical ring We use the fo...

Page 8: ...er Strasse 45 51 72654 Neckartenzlingen Germany Tel 49 0 1805 14 1538 E Mail HAC Support Belden com Internet http www hirschmann com We reserve the right to make technical modifications Hirschmann Automation and Control GmbH 2015 All Rights Reserved ...

Reviews: