background image

BEEM Outdoors  LLC. MODEL NO. : BMG5 

BEEM Outdoors LLC. Natural Gas & LPG 

Generator Set Model # BMG5 

 

Operation Instruction & Owner

s Manual

 

Caution:   

Carefully  read  and understand  this Owner’s  Manual  before  starting  this generator 

Summary of Contents for BMG5

Page 1: ...doors LLC MODEL NO BMG5 BEEM Outdoors LLC Natural Gas LPG Generator Set Model BMG5 Operation Instruction Owner s Manual Caution Carefully read and understand this Owner s Manual before starting this g...

Page 2: ...latest product information available at the time of approval for printing Every effort has been made to ensure the accuracy and completeness of the information in this manual We reserve the right to c...

Page 3: ...isk of serious injury or death Danger Danger indicates an imminently hazardous situation which if not avoided will result in death or serious injury Warning Warning indicates a potentially hazardous s...

Page 4: ...damaged or frayed 3 DO NOT operate generator in wet condition or with wet hand 4 DO NOT allow children or unqualified persons to operate or service the generator 5 DO NOT use a ground fault circuit i...

Page 5: ...enerator is disconnected and properly shut off disconnect the spark plug wire 7 When storing the generator store away from sparks open flames pilot lights heat and other sources of ignition Danger 1 R...

Page 6: ...BUTOR parts or their equivalent The set of replacement which is not equivalent quality may damage your generator Warning 1 DO NOT overload the generator 2 Start the generator and allow the engine to s...

Page 7: ...el Air fuel mixer series number Auto choke valve Spark plug cap Air filter Rubber leg Rubber mount Low oil sensor Engine oil drain plug Engine oil drain hole Engine oil fill cap Dipstick Starter Alter...

Page 8: ...alternator Air Cleaner Protects the engine by filtering dust and debris from the intake air Engine Air fuel Mixer Serial Number Please have this number available when calling for assistance Low Oil Se...

Page 9: ...C output Gas inlet Ground terminal Engine switch fuel switch Power output panel Read this owner s manual before operating your generator Familiarize yourself with the location and function of the cont...

Page 10: ...ttery cable 1 Gas pipe clip 1 Wrench 1 Vibration mount 4 12V 15AH battery 1 Cap screw M8 25 4 Cap screw M5 12 2 Washer 5 2 Spring Washer 5 2 Nut M5 2 Owner sManual 1 Certificate of Quality 1 Assembly...

Page 11: ...ion mount make sure NO LUBE OIL inside the crankcase Assembly Introduction Install vibration mount Install Battery Attach the red lead to the red terminal on the battery with cap screw nut Warning The...

Page 12: ...d engine oil and reinstall OIL FILL CAP DIPSTICK 4 Check engine oil level for each use and add as needed Lube oil capacity for different generator Running the engine with insufficient engine oil can c...

Page 13: ...end of gas pipeline until it s not easy to pull down from gas pipeline and prevent gas leaking 1 All gas pipe joints should be fixed tightly before operating the machine 2 Usually check the joints and...

Page 14: ...lectrician to ensure compliance with local electrical codes Grounding Connections for emergency power to household circuits must be made by a qualified electrician and must comply with all applicable...

Page 15: ...be as follow Working Condition Environment Requirement Gas Requirement Temperature for NG powered generator set 30 40 for LPG powered generator set 5 40 Sea level Height above sea level below 1000m Th...

Page 16: ...htly fixed not leaking 4 AC circuit breaker is at OFF position 5 AC output no load connected Disconnect all electrical loads from the generator set before starting engine The generator may be hard to...

Page 17: ...at least 5 feet about 1 5 meters of clearance from combustible material 2 Leave at least 3 feet about 1 meter of clearance on all side of the generator to allow for adequate cooling maintenance and s...

Page 18: ...pped with a low oil sensor that will prevent the engine from running when the oil level falls below a critical threshold Notice 1 This generator must have at least 5 feet about 1 5 meters of clearance...

Page 19: ...equipment or property 6 Be sure that appliances DO NOT exceed the rated load for more than 30 minutes and never exceed the maximum load Substantial overloading will switch off the circuit breaker Less...

Page 20: ...occur Caution Battery produces explosive gases Keep sparks flames and cigarettes away To prevent the possibility of creating a spark near the battery connect charging cables first to the battery then...

Page 21: ...he below operation steps Stop Engine in Normal Use 20 1 Turn off and unplug all electric loads Never start or stop the generator with electric devices plugged in or turned on 2 Let the generator run a...

Page 22: ...you begin and make sure you have the tools and skills required 2 Always follow the procedures and maintenance instructions in the owner s manual The Hour Meter records the total running hours the gen...

Page 23: ...chedule Notice Total running time Initial ration Every 1month Every 3months Every 6months Every 12months Item or 20h or 20h or 50h or 100h or 300h Spark plug Remove carbon adjust gas replace if necess...

Page 24: ...o drain completely Step 03 Reinstall the OIL DRAIN PLUG Step 04 Remove OIL FILL CAP DIPSTICK to add oil Caution 1 Change lube oil after 1st 20hours or 30 days use 2 After 1st use change lube oil every...

Page 25: ...hout the air cleaner Rapid engine wear may be result in Warning Caution 1 Remove the snap on cover holding the air filter to the assembly 2 Remove the foam element 3 Wash in liquid detergent and water...

Page 26: ...d the plug in by hand to prevent cross threading Tighten a new spark plug 1 2 turn with the wrench to compress the washer If you are reusing a plug it should only take 1 8 1 4 turn after the plug seat...

Page 27: ...el Mixer is not adjustable 3 Tampering with the governor can damage your generator and your electrical devices and will void your warranty 1 DO NOT spray engine with water water can contaminate the fu...

Page 28: ...tput decline or overheating Overloading Check loading and do an adjusting Refer to Power Management Gas pressure is out of range Change GAS SUPPLY SOURCE or contact your local dealer High ambient temp...

Page 29: ...Allow the engine to cool completely before storage 2 Clean the engine according to the instructions in the Maintenance section 3 Turn the ENGINE SWITCH to OFF position 4 Close the manual shutoff valv...

Page 30: ...d devices follow these steps to add electrical load 1 Start the generator with no electrical load attached 2 Allow the engine to run for several minutes to stabilize 3 Plug in and turn on the first it...

Page 31: ...W Furnace Fan 1 3 HP 1200W 2000W Home Appliances Running Watt Starting Watt Microwave 1000W 1000W Electric range one element 1500W Electric skillet 1250W Coffee Maker 1300W Clothes Washer 1200W Entert...

Page 32: ...frequency 230V 50Hz Single phase Engine Engine type Air cooled 4 stroke OHV Nos of cylinder mm Single cylinder Running speed rpm 3000 Ignition system TCI Starting mode Electric start Engine model 188F...

Page 33: ...ingle phase Engine Engine type Air cooled 4 stroke OHV Air cooled 4 stroke OHV Nos of cylinder mm Single cylinder Single cylinder Running speed rpm 3000 3000 Ignition system TCI TCI Starting mode Elec...

Page 34: ...Single phase Engine Engine type Air cooled 4 stroke OHV Air cooled 4 stroke OHV Nos of cylinder mm Single cylinder Single cylinder Running speed rpm 3600 3600 Ignition system TCI TCI Starting mode El...

Page 35: ...34 Accessories option Wheel 4pcs Washer 4pcs Axle 4pcs Axles pin 4pcs Kit 4 roues Brake stop Walk How to brake stop...

Page 36: ...Note 35...

Reviews: