background image

P5-16...L120-11

Model: E12

en

Assembly and Operating Instructions

Tubular drives for sun protection systems

Important information for:

• Fitters / • Electricians / • Users

Please forward accordingly!

These instructions must be kept safe for future reference.

Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

2010 301 012 0b     23/05/2022    

Summary of Contents for E12

Page 1: ...or sun protection systems Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com 2010 301 012 0b 23 05 2022 ...

Page 2: ...button 13 Setting the limit positions using the programming unit 13 Changing the additional stop behaviour function with the programming unit 15 Deleting the limit positions using the programming unit 16 Setting the limit positions with Auto Install 17 Obstacle detection 19 Activating deactivating the additional fabric untensioning function with the programming unit 19 Activating deactivating the ...

Page 3: ...g in connecting cable Please observe these Assembly and Operating Instructions when installing and setting up the equipment The date of manufacture comes from the first four digits of the serial number The numbers 1 and 2 indicate the year and the numbers 3 and 4 indicate the calendar week Example 34th calendar week in 2020 Ser No 2034XXXXX Explanation of pictograms CAUTION CAUTION indicates a haz...

Page 4: ...y the drive manufacturer If any questions or uncertainties regarding the safety instructions contained in the standard arise please contact the manufacturer of the part or end product in question All applicable standards and regulations for electrical installation must be complied with All work including maintenance and cleaning on electrical installations as well as other system parts must always...

Page 5: ...not be carried by the mains connecting cable All latching connections and fastening screws on the brackets must be checked to en sure that they are secure Ensure that nothing rubs against the tubular drive such as shading solution attach ments screws etc The drive must be fitted horizontally Intended use The type of tubular drive described in these instructions is intended solely for the operation...

Page 6: ...ver between the locating lug and the snap in pin so that the snap in pin releases the locat ing lug from the plug Now you can pull out the connecting cable along with the flat head screwdriver 1 2 3 A A snap in pin Ø45 Ø58 Insert a suitable flathead screwdriver right into the recess of the locating latch so that the latch releases the locating lug from the plug Now you can pull out the connecting ...

Page 7: ...he tab washer 1 upwards and pull out the mounting pin 2 Assembling and disassembling the drive adapter Fitting the ring onto the thrust ring Assembling the drive adapter with safety catch on the drive shaft Disassembling the drive adapter with safety catch on the drive shaft Assembling and disassembling the drive adapter with drive adapter safety catch or screw connection Assembling and disassembl...

Page 8: ...ar drive into the tube or drop it into the barrel 2 1 Assemble the tubular drive with the relevant ring 1 and drive adapter 2 If the ring has several grooves select the groove which is a perfect fit and push the ring 1 onto the thrust ring Insert the tubular drive with the pre assembled ring 1 and drive adapter 2 into the tube to achieve a form fit Ensure that the ring and drive adapter are secure...

Page 9: ...tion has been set in that direction of movement Setting the limit positions There are several ways to set the limit positions Extended point to retracted point Extended point to retracted stop The limit position becomes fixed after the tubular drive has turned off automatically in the desired position three times If the tubular drive switches off prematurely while extending retracting due to an ob...

Page 10: ...tracted limit position Now change the setting of the retracting direction of rotation switch from the delete setting to the programming setting The limit positions are now set Extended position to retracted stop Set both switches to the delete setting 1s Execute a short drive command Open to the desired extended limit position Change the setting of the extending direction of rotation switch from t...

Page 11: ...pletion of installation following automatic setting of limit position Stop Next time the stop limit position is travelled to this position will be provisionally saved as the limit position Once the limit position has been detected at this position 3 times in a row without any problems it will be definitively saved This normally takes place dur ing regular operation To complete installation quickly...

Page 12: ...t interruption between the individual drive commands The tubular drive confirms until STOP and hold until The limit positions are now set Extended point to retracted stop Set both switches to the programming setting Open to the desired extended limit position Carry out the following sequence without interruption between the individual drive commands The tubular drive confirms until STOP and hold u...

Page 13: ...travel to the stop limit position 3 times in a row from approx 20 cm Limit position status indicator A brief stopping and restarting indicates that no limit position has been set in that direction of movement Setting the limit positions There are several ways to set the limit positions Extended point to retracted point Extended point to retracted stop Auto install The limit position becomes fixed ...

Page 14: ...n to the desired retracted limit position Press the programming button of the programming unit for 3 seconds The tubular drive confirms The limit positions are now set Extended point to retracted stop with programming unit Set both switches to the programming setting Open to the desired extended limit position Press the programming button of the programming unit for 3 seconds The tubular drive con...

Page 15: ...ition must be set in order to adjust the stop behaviour The stop behaviour can be changed during the first 3 runs towards the stop Press the retract button in order to retract the sun protection system While retracting also press the programming button until the tubular drive switches off automatically at the stop and continue holding the two buttons down until con firmation is complete Confirmati...

Page 16: ... Deleting a limit position when 2 limit positions are programmed Any additional functions that have been set are retained black brown blue green yellow black brown blue green yellow Programming button Travel button Open close to the limit position to be deleted Press the programming button and keep it pressed Then press down the travel button and keep it pressed Now release the programming button ...

Page 17: ... has been detected at this position 3 times in a row without any problems it will be definitively saved This normally takes place dur ing regular operation To complete installation quickly it is sufficient to travel to the stop limit position 3 times in a row from approx 20 cm Limit position status indicator A brief stopping and restarting indicates that no limit position has been set in that dire...

Page 18: ...em is fully closed the tubular drive pulls the cloth slightly more strongly during the installa tion Auto point to retracted stop only with articulated arm awnings Attention Ensure that the cloth is not wound up the wrong way by the barrel Retract Extend Set both switches to the programming setting Extend the articulated arm awning until the articulated arms are fully protracted and the cloth is l...

Page 19: ...nal fabric untensioning function with the programming unit The to retracted stop limit position must be set for the fabric untensioning function On delivery the fabric tensioning function is deactivated on tubular drives with a diameter of 35 mm and is activated on tubular drives with diameters of 45 mm and 58 mm To activate deactivate it move to the Retract limit position Press the programming bu...

Page 20: ...mains with a contact gap of at least 3 mm per pole must be provided Attention Only use mechanically or electrically locked switching elements with a marked zero posi tion This also applies when drives with electronic and mechanical limit switching are used in the same system The changeover time for switching the running direction must be at least 0 5 s The switch and control must not execute simul...

Page 21: ... 44 Min tube inside diameter mm 37 Emission sound pressure level dB A 70 Technical data dia 45 Tubular drive R8 17 R12 17 R20 17 R30 17 R40 17 R50 11 Model E12 Type C PS V1 Rated torque Nm 8 12 20 30 40 50 Output speed rpm 17 17 17 17 17 11 Limit switch range 64 revolutions Supply voltage 230 V AC 50 Hz Connected load W 100 110 160 205 260 240 Rated current consumption A 0 45 0 50 0 75 0 90 1 15 1...

Page 22: ...in Degree of protection IP 44 Min tube inside diameter mm 60 Emission sound pressure level dB A 70 Tubular drive L80 11 L80 17 L120 11 Model E12 Type C PS V1 Rated torque Nm 80 80 120 Output speed rpm 11 17 11 Limit switch range 64 revolutions Supply voltage 230 V AC 50 Hz Connected load W 310 470 435 Rated current consump tion A 1 40 2 10 1 90 Operating mode S2 4 min Degree of protection IP 44 Mi...

Page 23: ...connection Tubular drive only runs for approx 1 second Tubular drive is faulty Replace the tubular drive Setting the limit positions using the programming unit does not work Set both switches to the delete setting Execute a short drive command Set both switches to the programming setting simultaneously Re set the limit positions using the programming unit Setting the limit positions using the swit...

Page 24: ...Sample wiring diagram Controlling one several drive s via a single switch button Controls black brown blue green yellow Controls 24 en ...

Page 25: ...Declaration of conformity 25 en ...

Page 26: ...26 ...

Page 27: ...27 ...

Page 28: ......