Assembly and Operating Instructions

 

 

Sectional door drives

 

Important information for:
• Fitters / • Electricians / • Users
Please forward accordingly!
These instructions must be kept safe for future reference.

 

Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

 

Summary of Contents for A100/25 5E

Page 1: ...tions Sectional door drives Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com ...

Page 2: ... overview and dimensions 5 Installation 6 Emergency manual operation 7 Voltage switching 11 Electrical connection to the control unit and connection diagram 12 Checking the running direction 14 Setting the door limit positions 14 Maintenance 15 Technical data 16 Declaration of incorporation 17 2 ...

Page 3: ...ficial and in particular EMC regu lations are adhered to during utilisation of our products especially with regard to end product manufacture installation and cus tomer advice Intended use The type of plug in drive featured in these instructions is exclusively designed for indoor use for the operation of sectional doors whose inherent weight is balanced by springs or a counterweight or for special...

Page 4: ...s or modifications to the system and its accessories represent a risk to your safety and the safety of others This means that the use of unapproved third party products or modifica tions which have not been agreed with or approved by us are prohibited We do not accept liability for dam age or injury arising from such actions The limits given in the technical data must not be exceeded When installi...

Page 5: ...Product overview and dimensions All dimensions in mm Drives with a crank handle HK Drives with a light chain LK Ø 85 Ø 25 4 27 6 6 35 JS9 M 8 x 10 Hole pattern 5 ...

Page 6: ...f the fastening screws for securing the drive must be at least 20 Nm and no more than 25 Nm Failure to observe this may result in damage to the product or ob jects in the immediate vicinity Once the sectional door has been mounted and properly counterweighted the door must be counterweighted in every position The correct counterweight is manually adjusted by opening and closing the door When insta...

Page 7: ... safety limit switch S1F S2F is released via emergency manual operation 2 different systems are available for emergency manual operation Crank handle HK Light chain LK Note For each type of emergency manual override system an appropriate notice as per EN60335 2 103 must be permanently placed in the vicinity of the corresponding operating element describing how it is to be used Stickers for use as ...

Page 8: ...h strands of the chain Light chain LK In the case of vertical drive installation 1 2 Note The drive can be installed vertically at an installation height of up to ap prox 8 m From an installation height of approx 8 m the drive must be installed horizontally Installation of the chain wheel Mount the chain on the chain wheel so that there are approx 10 chain links over hanging on one side 1 Then fee...

Page 9: ...chain cross provided 7 in accordance with its alignment Pull the chain end which has just been inserted through the chain cross until approx 10 chain links are protruding from the chain wheel at the other end of the chain Then proceed in the same way with the other side and also feed this end of the chain through the chain cross in accordance with its alignment 9 ...

Page 10: ... coupling and decoupling of the emergency manual operation mechanism the chain must be kept taut during operation The door can be opened and closed manually by pulling the respective side of the chain vertically In order to prevent electrical operation of the door system during emergency manual operation the safety switch S3F is activated when the chain is pulled After operation ensure that the ch...

Page 11: ... 5E 3 400 V network factory gearing TP gn br rt sw bl ge U gn green V bl blue W ge yellow br brown rt red sw black 3 230V system TP br rt sw gn bl ge U gn green V bl blue W ge yellow br brown rt red sw black Voltage switching for A100AE 3 230 V 3 230 V 3 400 V 3 230 V 2 3 1 For operation on a 3 230 V network the adapter 1 with Item no 4822 200 203 0 must be used This is connected between the motor...

Page 12: ... cable which has been approved by the manufac turer The connecting cable is plug in In order to ensure strain relief and the degree of protection the gland must not be undone The plug is fitted with reverse polarity protection and clicks audibly into place The yellow green protective conductor wire must be connected to the designated push on connector Make sure that it engages firmly 12 1 2 3 4 5 ...

Page 13: ... 7 8 S4F thermoswitch 9 10 S3F safety limit switch HK LK 11 12 Jumper possible connection point for external safety elements Install the individual wires of the connecting cable to the right of the central dome of the housing as shown in the diagram Install the protective conductor green yellow below the black connecting cables Secure the connecting cable to the internal motor cables using the sup...

Page 14: ...screw slotted to manually set the cam in such a way that it activates the switch Move the door slightly up and down again until the end switch stops the door Fine tune the setting as necessary 4 Now move the door to just before the upper limit position 5 Now set the grey cam S5 OPEN in the same way as described in point 3 6 Now set the yellow safety cams S1F UP and S2F DOWN to lag both operational...

Page 15: ...ng the emergency manual operation function keep opening up to the point where no damage occurs The safety switch S1F must be checked as per the connection diagram There must be no continuity Re S2F CLOSE applies to cam operated limit switching Close to the lower limit position Using the emergency manual operation function continue closing until the load bearing medium e g cables or chains for susp...

Page 16: ...H Thermoswitch C 170 Mode S3 40 Degree of protection IP 54 Limit switch range Revolutions 13 Static holding torque Nm 450 On site fuse protection 3 x10 AT Permissible ambient operating temperature C 20 to 40 Weight approx kg 10 with LK version the weight increases by approx 0 5 kg Deviations are possible in structurally identical drives or special drives The information on the type plate always ap...