background image

An issued or revision date for these instructions is included for the user’s
information.  In the event two years have elapsed between this date and
product use, the user should contact Bard Access Systems to see if 
additional product information is available.

Revised date:  March 2007                 

*Bard, RadPICC, Hydro-Glide, StatLock and Per-Q-Cath are trademarks
and/or registered trademarks of C. R. Bard, Inc. or an affiliate.

U.S. Patent:  4,772,266.

© Copyright 2007 C. R. Bard, Inc.  All rights reserved.  

PK0714229  /  0703R     

Bard Access Systems, Inc.

Salt Lake City, UT 84116  USA

1-801-595-0700

Clinical Information Hotline:

1-800-443-3385

Ordering Information:

1-800-545-0890

Bard Access Systems

I n s t r u c t i o n s   F o r   U s e

Bard Access Systems

C a t h e t e r s   w i t h
M i c r o i n t r o d u c e r   S e t

Summary of Contents for Poly RadPICC

Page 1: ...adPICC Hydro Glide StatLock and Per Q Cath are trademarks and or registered trademarks of C R Bard Inc or an affiliate U S Patent 4 772 266 Copyright 2007 C R Bard Inc All rights reserved PK0714229 0703R Bard Access Systems Inc Salt Lake City UT 84116 USA 1 801 595 0700 Clinical Information Hotline 1 800 443 3385 Ordering Information 1 800 545 0890 Bard Access Systems I n s t r u c t i o n s F o r...

Page 2: ...tylet 3 Apply Tourniquet and Drape 4 Perform Venipuncture 5 Advance Guidewire 6 Remove Needle 7 Introduce Microintroducer 8 Measure Distance to Tip Location 9 Removing Dilator and Guidewire 10 Modification of Catheter Length 11 Insert and Advance the Catheter 12 Retract and Remove Microintroducer Sheath 13 Complete Catheter Insertion 14 Aspirate and Flush 15 Dress Catheter 16 Verify Placement 13 S...

Page 3: ...lowing air entry while changing injection caps hold the connector below the level of the patient s heart before removing the injection cap Place a finger over the needle to minimize blood loss and risk of air aspiration The risk of air aspiration is reduced by performing this part of the procedure with the patient holding his breath until the guidewire is inserted into the needle Product Descripti...

Page 4: ...lumen is opened or connected to other devices Precautions are intended to help avoid catheter damage and or patient injury I Prior to placement Examine the package carefully before opening to confirm its integrity and that the expiration date has not passed The catheter is supplied in a sterile package and is non pyrogenic Do not use if package is damaged opened or the expiration date has passed S...

Page 5: ... fossa is recommended 3 Release tourniquet 4 Set up the sterile field Bard Access Systems 6 Bard Access Systems 5 2 Preflush the Catheter and Stylet 1 Flush the catheter with heparinized saline solution or sterile water Note The catheter may be trimmed if a shorter length is required 2 Attach a syringe with heparinized saline solution or sterile normal saline to the Luer Lock fitting of the flush ...

Page 6: ...w antecubital fossa may result in an increased incidence of phlebitis Placement of PICC above antecubital fossa is recommended 5 Advance Guidewire 1 Introduce the guidewire through the nee dle advance the guidewire 15 to 20cm into the vessel Caution Do not advance the wire past the axilla without fluoroscopic guidance 6 Remove Needle 1 Release tourniquet Apply slight pres sure on the vessel above ...

Page 7: ...ir aspira tion The risk of air embolism is reduced by performing this part of the procedure with the patient performing the Valsalva maneuver or by attaching a syringe or injection cap to the dilator to reduce blood flow while trimming the catheter 10 Modification of Catheter Length Note Catheters can be cut to length if a different length is desired due to patient size and desired point of inser ...

Page 8: ...ize blood loss 14 Aspirate and Flush 1 Attach primed extension set and or saline filled syringe 2 Aspirate for adequate blood return and flush each lumen of the catheter to ensure patency Zero mark Single Lumen Dual Lumen StatLock Stabilization Device Procedure Single Lumen Dual Lumen Tape Strip Securement Procedure 1 Secure catheter with StatLock stabilization device 2 Cover site and StatLock sta...

Page 9: ...Hotline 1 800 443 3385 Ordering 1 800 545 0890 www bardaccess com Home Healthcare Agency ______________________________ Agency Phone No ______________________________ ________________________________________________________ Patient Information Card Bard Access Systems C a t h e t e r s w i t h M i c r o i n t r o d u c e r S e t When cleaning around your catheter Follow all instructions you are gi...

Reviews: