background image

                                                                                             

   

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com 

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com                             

       

 

 

Product Description

 

Model EIR618-2SFP-T

 

Documentation Number:    EIR618-2SFP-T_5107m 

 

 

 

 

 

 

 

 

 

  707 Dayton Road  --  P.O. Box 1040  --  Ottawa, IL  61350 USA 

    Phone (815) 433-5100 -- General Fax (815) 433-5105   

 

Phone

 (815) 433-5100 -- 

General Fax

 (815) 433-5105   

Website: 

www.bb-elec.com

 

Sales

 e-mail: 

[email protected]

 -- 

Fax

 (815) 433-5109 

Technical Support

 e-mail: 

[email protected]

 -- 

Fax

 (815) 433-5104 

 

 

 

European Headquarters 

B&B Electronics 

Westlink Commercial Park -- Oranmore, Co.    Galway, Ireland 

Phone

 +353 91-792444 -- 

Fax 

+353 91-792445 

Website: 

www.bb-europe.com

 

Sales

 e-mail: 

[email protected]

 

Technical Support

 e-mail: 

[email protected]

 

 

 

 

B&B Electronics Mfg. Co. Inc.  --  December 2007 

Summary of Contents for EIR618-2SFP-T

Page 1: ...d P O Box 1040 Ottawa IL 61350 USA Phone 815 433 5100 General Fax 815 433 5105 Phone 815 433 5100 General Fax 815 433 5105 Website www bb elec com Sales e mail orders bb elec com Fax 815 433 5109 Technical Support e mail support bb elec com Fax 815 433 5104 European Headquarters B B Electronics Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 792445 Website www bb...

Page 2: ......

Page 3: ...Eighteen Port Managed Industrial Ethernet Switches User Manual ...

Page 4: ...www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com The contents of this manual are based on the firmware kernel version and hardware version listed below Firmware Version V1 07 Kernel Version V2 07 Hardware Version Notice ...

Page 5: ...t occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipme...

Page 6: ......

Page 7: ...ware Description 6 Physical Dimension 6 Front Panel 6 Top View 7 LED Indicators 8 Ports 9 Cabling 11 Wiring the Power Inputs 14 Wiring the Fault Alarm Contact 15 Mounting Installation 16 DIN Rail Mounting 16 Wall Mount Plate Mounting 18 Hardware Installation 19 Network Application 20 ...

Page 8: ... Application 21 Dual Homing Application 22 Console Management 23 Connecting to the Console Port 23 Pin Assignment 23 Login in the Console Interface 24 CLI Management 25 Commands Level 26 Commands Set List 27 System Commands Set 27 Port Commands Set 30 Trunk Commands Set 32 VLAN Commands Set 33 Spanning Tree Commands Set 35 QOS Commands Set 38 IGMP Commands Set 38 Mac Filter Table Commands Set 39 S...

Page 9: ...b Management 50 System Login 51 System Information 52 IP Configuration 52 DHCP Server System configuration 54 DHCP Server Client Entries 54 DHCP Server Port and IP Bindings 55 TFTP Update Firmware 56 TFTP Restore Configuration 56 TFTP Backup Configuration 57 System Event Log Syslog Configuration 57 System Event Log SMTP Configuration 58 System Event Log Event Configuration 59 ...

Page 10: ...com Fault Relay Alarm 61 SNTP Configuration 61 IP Security 64 User Authentication 65 Port Statistics 66 Port Control 67 Port Trunk 68 Aggregator setting 68 Aggregator Information 70 State Activity 70 Port Mirroring 72 Rate Limiting 73 VLAN configuration 74 VLAN configuration Port based VLAN 74 802 1Q VLAN 77 Rapid Spanning Tree 80 RSTP System Configuration 80 RSTP Port Configuration 81 SNMP Config...

Page 11: ...riority Type 88 Port based Priority 89 COS Configuration 90 TOS Configuration 90 IGMP Configuration 90 X Ring 92 Security 94 802 1X Radius Configuration 94 MAC Address Table 97 Factory Default 99 Save Configuration 100 System Reboot 100 Trouble shooting 101 Technical Specification 102 ...

Page 12: ...fg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com ...

Page 13: ...etwork infrastructure has been established without requiring extra upgrade costs In addition to 10 100 1000Base TX fast Ethernet ports the switch has SFP mini GBIC ports Traditional RJ 45 ports can be used for up linking short distance less than 100 m wide band paths while the SFP slots can be used for the application of wideband uploading and long distance transmissions adding flexibility Feature...

Page 14: ...vice IEEE 802 1p Class of Service Four priority queues per port Port Base Tag Base and Type of Service Priority Bandwidth Control Ingress Packet Filter and Egress Rate Limit Broadcast Multicast Packet Filter Control Port Mirror Monitor traffic in switched networks TX Packet only RX Packet only Both of TX and RX Packet System Event Log System Log Server Client SMTP e mail Alert Relay Alarm Output S...

Page 15: ...nt Web interface management Telnet interface management Command Line Interface CLI management SNMP MIB RFC 1215 Trap RFC 1213 MIBII RFC 1157 SNMP MIB RFC 1493 Bridge MIB RFC 2674 VLAN MIB RFC 1643 RFC 1757 RSTP MIB Private MIB VLAN Port based VLAN IEEE802 1Q Tag VLAN 256 entries VLAN ID up to 4k in number which can be assigned from 1 to 4096 GVRP 256 groups Double Tag VLAN Q in Q Private VLAN Port...

Page 16: ...ping v1 v2 and v3 Up to 256 multicast groups and IGMP query IP Security Supports 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder Login Security Supports IEEE 802 1X Authentication RADIUS Bandwidth control Supports ingress packet filter and egress packet limit The egress rate control supports all of packet type and the limit rates are 100K 2...

Page 17: ...te Trap for power status Power Alarm configuration Fault Alarm X Ring topology change DHCP Provides DHCP Client DHCP Server function DNS Provides DNS client feature Supports Primary and Secondary DNS Server SNTP Supports SNTP to synchronize system clock in Internet Firmware update TFTP firmware update TFTP backup and restore Configuration upload and download Supports binary configuration file for ...

Page 18: ...350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Hardware Description Physical Dimension W x D x H 2 83 x 4 13 x 5 98 in 7 2mm x 10 5mm x 15 2 cm Front Panel Front Panel of the industrial switch ...

Page 19: ...s Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Top View Top Panel of the industrial switch ...

Page 20: ...f the X Ring group R M Off The industrial switch is not the master of the X Ring group Green Power Source 1 is Available PWR1 Off Power Source 1 is Unavailable Green Power Source 2 is Available PWR2 Off Power Source 2 is Unavailable Red Power or port failure Fault Off Normal Operation Green Upper LED Connected to network Blinking Upper LED Network is active Off Upper LED Not connected to network Y...

Page 21: ...twork is active Off Upper LED Not connected to network Green Lower LED The port is operating at 1000M Off Lower LED The port is disconnected or operating at 10 100M Green SFP port is connected to network Blinking Network is active P17 18 Link Active 100 1000 SFP Off Not connected to network Ports RJ 45 ports RJ 45 ports Auto MDI MDIX The RJ 45 ports are auto sensing for 10Base T 100Base TX or 1000...

Page 22: ...h Cable Schematic Cross Over Cable Schematic Gigabit Copper SFP Mini GBIC combo port The Industrial switch has auto detecting Giga UTP STP Fiber combo ports The Gigabit Copper 10 100 1000T ports should use Category 5e or above UTP STP cable The SFP slots are for connecting to the network segment with single or multi mode fiber The small form factor pluggable SFP is a compact optical transceiver us...

Page 23: ...able between the link partner switch hub workstation etc and the converter must be less than 100 meters 328 ft long and comply with the IEEE 802 3ab 1000Base T standard for Category 5e or above Single mode fiber links must use 9 125μm single mode fiber cable Multi mode fiber links must use 50 125 or 62 5 125μm multi mode fiber cable The small form factor pluggable SFP is a compact optical transcei...

Page 24: ...cs Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Ensure the module is aligned correctly and then slide the module into the SFP slot until a click is heard Transceiver Inserted Insert the fiber cable into the transceiver LC connector to the transceiver To remove the fiber cable from the transceiver follow the steps shown below ...

Page 25: ...5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Press the upper side of the LC connector from the transceiver and pull it out to release Remove LC connector Push down the metal loop and pull the transceiver out by the plastic part Pull out from the SFP module ...

Page 26: ...104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Wiring the Power Inputs Please follow the steps below to insert the power wire 1 Insert the positive and negative leads into the V and V contacts on the terminal block connector 2 To tighten the wire clamp screws ...

Page 27: ...tawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector Note Use 12 to 24 AWG wire ...

Page 28: ...07 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Mounting Installation DIN Rail Mounting Rear Panel of the switch DIN Rail ...

Page 29: ...www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 1 First insert the top of the DIN Rail clip into the track 2 Then lightly push into the track 3 Ensure the DIN Rail clip is tightly secured to the track 4 To remove the industrial switch from the track reverse steps above ...

Page 30: ...ay Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Panel Mounting Follow the steps as below to mount the industrial switch with wall mount plate 1 Remove the DIN Rail from the industrial switch 2 Place the panel mount plate on the rear panel 3 Use the screws to attach the panel mount 4 Use the hook holes at the corners of the plate to mount the switch to the To remove the wall mount p...

Page 31: ...ation Steps 1 Unpack the Industrial switch 2 Ensure the DIN Rail is tightly screwed to the Industrial switch If not refer to DIN Rail Mounting section for DIN Rail installation To panel mount the Industrial switch refer to Panel Mounting section 3 Apply power to the switch refer to the Wiring the Power Inputs section The power LED will light 4 Connect CAT 5 cables to the Industrial switch s RJ 45 ...

Page 32: ...ay Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Network Application X Ring Application This switch incorporates the X Ring Protocol to ensure network reliability and system restoration within 300 ms in the event of a connection failure The X Ring algorithm is similar to the spanning tree protocol STP algorithm but it has faster recovery time The following figure below is an example...

Page 33: ...cs Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Coupling Ring Application If the network has more than one X Ring group the coupling ring function is used to connect them and add redundancy This ensures that transmissions between the two ring groups will not fail The figure below is an example of the coupling ring application ...

Page 34: ...Homing Application The Dual Homing function is used to prevent a connection loss between the X Ring group and the upper level core switch Assign a port in each X ring group to be the Dual Homing ports The Dual Homing function can only be used when the X Ring function is active Each X Ring group can have one Dual Homing port Note The upper level switches must have RSTP enabled NOTE In Dual Homing a...

Page 35: ...e Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Console Management Connecting to the Console Port Attach the DB9 end to a PC or terminal and the RJ 45 end to the console port on the switch The PC must have support a terminal emulation program Pin Assignment DB9 Connector RJ 45 Connector NC 1 Orange White 2 2 Orange 3 3 Green White NC 4 Blue 5 5 Blue White NC 6 Green NC 7 Brow...

Page 36: ...Login in the Console Interface When the connection between Switch and PC is ready turn on the PC run a terminal emulation program or Hyper Terminal and configure the following communication parameters Baud Rate 9600 bps Data Bits 8 Parity none Stop Bit 1 Flow control None The settings of communication parameters After entering the parameter click OK When the blank screen shows up press Enter on th...

Page 37: ...0 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Console login interface CLI Management After you login to the system you will see a command prompt To enter CLI management interface type enable and press enter CLI command interface ...

Page 38: ...sts Display system information Privileged EXEC Enter the enable command while in User EXEC mode switch Enter disable to exit The privileged command is the advanced mode Use this mode to Display advanced function status Save configuration Global Configuration Enter the configure command while in privileged EXEC mode switch config To exit to privileged EXEC mode enter exit or end Use this mode to co...

Page 39: ... ports Commands Set List User EXEC E Privileged EXEC P Global configuration G VLAN database V Interface configuration I System Commands Set Commands Level Description Example show config E Show switch configuration switch show config show terminal P Show console information switch show terminal write memory P Save user configuration into permanent memory flash rom switch write memory system name S...

Page 40: ...erform a cold restart switch config reload default G Restore to default switch config default admin username Username G Changes a login username maximum 10 words switch config admin username xxxxxx admin password Password G Specifies a password maximum 10 words switch config admin password xxxxxx show admin P Show administrator information switch show admin dhcpserver enable G Enable DHCP Server s...

Page 41: ... Show client entries of DHCP server switch show dhcpserver clients show dhcpserver ip binding P Show IP Binding information of DHCP server switch show dhcpserver ip binding no dhcpserver G Disable DHCP server function switch config no dhcpserver security enable G Enable IP security function switch config security enable security http G Enable IP security of HTTP server switch config security http ...

Page 42: ...eed configuration command to specify the speed mode of operation for Fast Ethernet the speed can t be set to 1000 if the port isn t a giga port switch config interface fastEthernet 2 switch config if speed 100 no flowcontrol I Disable flow control of interface switch config if no flowcontrol security enable I Enable security of interface switch config interface fastEthernet 2 switch config if secu...

Page 43: ...nly accept broadcast frame switch config interface fastEthernet 2 switch config if bandwidth type broadcast only bandwidth in Value I Set interface input bandwidth Rate Range is from 100 kbps to 102400 kbps or to 256000 kbps for giga ports and zero means no limit switch config interface fastEthernet 2 switch config if bandwidth in 100 bandwidth out Value Set interface output bandwidth Rate Range i...

Page 44: ...ce status show interface accounting I show interface statistic counter switch config interface fastEthernet 2 config if show interface accounting no accounting I Clear interface accounting information switch config interface fastEthernet 2 switch config if no accounting Trunk Commands Set Commands Level Description Example aggregator priority 1 65535 G Set port group system priority switch config ...

Page 45: ...s parameter could be a port range ex 1 4 or a port list separate by a comma ex 2 3 6 switch config aggregator group 1 2 4 nolacp or switch config aggregator group 1 3 1 2 nolacp show aggregator P Show the information of trunk group switch show aggregator 1 or switch show aggregator 2 or switch show aggregator 3 no aggregator lacp GroupID G Disable the LACP function of trunk group switch config no ...

Page 46: ...te port base group ID switch vlan no vlan group 2 IEEE 802 1Q VLAN vlan 8021q name GroupName vid VID V Change the name of VLAN group if the group didn t exist this command can t be applied switch vlan vlan 8021q name test vid 22 vlan 8021q port PortNumber access link untag UntaggedVID V Assign an access link for VLAN by port if the port belongs to a trunk group this command can t be applied switch...

Page 47: ...r switch vlan vlan 8021q trunk 3 trunk link tag 3 20 vlan 8021q trunk PortNumber hybrid link untag UntaggedVID tag TaggedVID List V Assign a hybrid link for VLAN by trunk group switch vlan vlan 8021q trunk 3 hybrid link untag 4 tag 3 6 8 or switch vlan vlan 8021q trunk 3 hybrid link untag 5 tag 6 8 show vlan GroupID or show vlan V Show VLAN information switch vlan show vlan 23 no vlan group GroupI...

Page 48: ... STP topology spanning tree hello time seconds G Use the spanning tree hello time global configuration command to specify the interval between hello bridge protocol data units BPDUs switch config spanning tree hello time 3 spanning tree forward time seconds G Use the spanning tree forward time global configuration command to set the forwarding time for the specified spanning tree instances The for...

Page 49: ... 20 stp path priority Port Priority I Use the spanning tree port priority interface configuration command to configure a port priority that is used when two switches tie for position as the root switch switch config interface fastEthernet 2 switch config if stp path priority 128 stp admin p2p Auto True False I Admin P2P of STP priority on this interface switch config interface fastEthernet 2 switc...

Page 50: ...nly tos only cos first tos first G Setting of QOS priority type switch config qos prioritytype qos priority portbased Port lowest low middle high G Configure Port based Priority switch config qos priority portbased 1 low qos priority cos Priority lowest low mid dle high G Configure COS Priority switch config qos priority cos 0 middle qos priority tos Priority lowest low mid dle high G Configure TO...

Page 51: ...figure MAC address table of interface static switch config interface fastEthernet 2 switch config if mac address tab le static hwaddr 000012345678 mac address table filter hwaddr MAC G Configure MAC address table filter switch config mac address table filter hwaddr 000012348678 show mac address table P Show all MAC address table switch show mac address table show mac address table static P Show st...

Page 52: ...t SNMP agent system contact switch config snmp system contact where snmp agent mode v1v2c v3 v1v2cv3 G Select the agent mode of SNMP switch config snmp agent mode v1v2cv3 snmp community strings Community right RO RW G Add SNMP community string switch config snmp community strings public right rw snmp server host IP address community Community string trap version v1 v2c G Configure SNMP server host...

Page 53: ...1 security level AuthPriv match rule Exact views V1 V1 V1 snmpv3 mibview view View Name type Excluded Included sub oid OID G Configure the mibview table of SNMPV3 agent switch config snmpv3 mibview view V1 type Excluded sub oid 1 3 6 1 show snmp P Show SNMP configuration switch show snmp no snmp community strings Community G Remove the specified community switch config no snmp community strings pu...

Page 54: ... G Remove specified mibview table of SNMPV3 agent switch config no snmpv3 mibview view V1 type Excluded sub oid 1 3 6 1 Port Mirroring Commands Set Commands Level Description Example monitor RX TX Both I Configure source port of monitor function switch config interface fastEthernet 2 switch config if monitor RX monitor rx Port ID G Set RX destination port of monitor function switch config monitor ...

Page 55: ... system radius IP global configuration command to change the radius server IP switch config 8021x system radiusip 192 168 1 1 8021x system serverport port ID G Use the 802 1x system server port global configuration command to change the radius server port switch config 8021x system serverport 1815 8021x system accountport port ID G Use the 802 1x system account port global configuration command to...

Page 56: ...ch config 8021x misc txperiod 5 8021x misc supportimeout sec G Use the 802 1x misc supp timeout global configuration command to set the supplicant timeout switch config 8021x misc supportimeout 20 8021x misc servertimeout sec G Use the 802 1x misc server timeout global configuration command to set the server timeout switch config 8021x misc servertimeout 20 8021x misc maxrequest number G Use the 8...

Page 57: ...onfig no 8021x TFTP Commands Set Commands Level Description Defaults Example backup flash backup_cfg G Save configuration to TFTP and need to specify the IP of TFTP server and the file name of image switch config backup flash backup_cfg restore flash restore_cfg G Get configuration from TFTP server and need to specify the IP of TFTP server and the file name of image switch config restore flash res...

Page 58: ...tication switch config smtp authentication smtp account account G Configure authentication account switch config smtp account John smtp password password G Configure authentication password switch config smtp password 1234 smtp rcptemail Index Email address G Configure Rcpt e mail Address switch config smtp rcptemail 1 Alert test com show smtp P Show the information of SMTP switch show smtp no smt...

Page 59: ...ure no event X ring topology change G Disable X ring topology changed event type switch config no event X ring topology change no event systemlog I Disable port event for system log switch config interface fastethernet 3 switch config if no event systemlog no event smpt I Disable port event for SMTP switch config interface fastethernet 3 switch config if no event smtp show systemlog P Show system ...

Page 60: ...timezone Timezone G Set timezone index use show sntp timzezone command to get more information of index number switch config sntp timezone 22 show sntp P Show SNTP information switch show sntp show sntp timezone P Show index number of time zone list switch show sntp timezone no sntp G Disable SNTP function switch config no sntp no sntp daylight G Disable daylight saving time switch config no sntp ...

Page 61: ...switch config Xring couplingport 1 Xring controlport Control Port G Configure Control Port switch config Xring controlport 2 Xring homingport Dual Homing Port G Configure Dual Homing Port switch config Xring homingport 3 show Xring P Show the information of X Ring switch show Xring no Xring G Disable X ring switch config no X ring no Xring master G Disable ring master switch config no Xring master...

Page 62: ...nagement features and allows the switch to be configured from anywhere on the network The web site is designed for Internet Explorer 6 0 and uses Java Applets to reduce bandwidth consumption enhance access speed and present an intuitive user interface Preparing for Web Management Before using web management install the industrial switch on the network and verify that a PC on the local network can ...

Page 63: ...ial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com System Login 1 Launch Internet Explorer on the PC 2 Key in http the IP address of the switch and then Press Enter 3 The login screen will appear 4 Enter the user name and password The default user name and password are root 5 Press Enter or click OK button and then the home screen of the Web based management appe...

Page 64: ...m Name A name 64 bytes max can be assigned to the switch System Description Displays the description of switch Read only cannot be modified System Location A physical location 64 bytes max can be assigned to the switch System Contact Enter the name of contact person or organization Firmware Version Displays the switch s firmware version Kernel Version Displays the kernel software version MAC Addre...

Page 65: ...ssigned by the network DHCP server The default IP address will be replace by the DHCP server assigned IP address After clicking the Apply button a popup dialog will indicate that the current IP will be lost and the new IP address must be retrieved from the DHCP server IP Address A static IP Address may be assigned The default IP is 192 168 16 1 Subnet Mask Assign the subnet mask of the IP address ...

Page 66: ... Server Enable or Disable the DHCP Server function Low IP Address the dynamic IP assign range Low IP address is the beginning of the dynamic IP assignment range High IP Address the dynamic IP assign range High IP address is the end of the dynamic IP assignment range Subnet Mask The subnet mask Gateway The network gateway DNS Network Domain Name Server IP Address Lease Time sec The time interval at...

Page 67: ... Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com DHCP Client Entries interface DHCP Server Port and IP Bindings You can assign a specific IP address that is in the dynamic IP assignment range to the specific port When the device is connected to the port and asks for an assignment the system will assign this IP address Port and IP Bindings interface ...

Page 68: ...y to update the switch s firmware Before updating ensure you the TFTP server is ready and the firmware image is on the TFTP server 1 TFTP Server IP Address Enter the TFTP server IP 2 Firmware File Name Enter the name of firmware image 3 Click Apply Update Firmware interface TFTP Restore Configuration If the EEPROM image is stored on the TFTP server you can restore it to flash memory 1 TFTP Server ...

Page 69: ...current EEPROM image to the TFTP server 1 TFTP Server IP Address Enter the TFTP server IP 2 Backup File Name Enter the file name 3 Click Apply Backup Configuration interface System Event Log Syslog Configuration Configure the system event mode to collect system log 1 Syslog Client Mode Select the system log mode client only server only or both 2 System Log Server IP Address Assigned the system log...

Page 70: ...uration Set up the mail server IP mail account account password and email account for receiving event alerts 1 Email Alert enable or disable the email alert function 2 SMTP Server IP set up the mail server IP address 3 Sender Enter the email address e g switch102 123 com to identify where the event log came from 4 Authentication Mark the check box to enable and configure the email account and pass...

Page 71: ...m Password reconfirm the password 8 Rcpt e mail Address 1 through 6 Enter up to six email addresses to receive the event log 9 Click Apply button SMTP Configuration interface System Event Log Event Configuration When the selected events occur the system will generate a log entry and email notification message System event selection Four selections available Cold Start Warm Start SNMP Authenticatio...

Page 72: ...04 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Port event selection When a port specific event occurs the system will generate a log entry and email notification Three selections are available Link UP Link Down and Link UP Link Down Event Configuration interface ...

Page 73: ...ower Failure When the check box is marked the Fault LED will light if the power source fails Port Link Down Broken When the check box is marked the Fault LED will light if a port link goes down Fault Relay Alarm interface SNTP Configuration The SNTP allows you to synchronize switch clocks 1 SNTP Client Enables or disables the SNTP function 2 Daylight Saving Time Enables or disables daylight saving...

Page 74: ...Atlantic Daylight 3 hours 9 am AST Atlantic Standard EDT Eastern Daylight 4 hours 8 am EST Eastern Standard CDT Central Daylight 5 hours 7 am CST Central Standard MDT Mountain Daylight 6 hours 6 am MST Mountain Standard PDT Pacific Daylight 7 hours 5 am PST Pacific Standard ADT Alaskan Daylight 8 hours 4 am ALA Alaskan Standard 9 hours 3 am HAW Hawaiian Standard 10 hours 2 am Nome Alaska 11 hours ...

Page 75: ... 6 hours 6 pm WAST West Australian Standard 7 hours 7 pm CCT China Coast USSR Zone 7 8 hours 8 pm JST Japan Standard Russia Zone 8 9 hours 9 pm EAST East Australian Standard GST Guam Standard Russia Zone 9 10 hours 10 pm IDLE International Date Line NZST New Zealand Standard NZT New Zealand 12 hours Midnight 4 SNTP Sever URL Enter the SNTP server IP address 5 Daylight Saving Period Enter the Dayli...

Page 76: ...urity function grants 10 specific IP addresses permission to access the switch through a web browser or TELNET for management IP Security Mode When enabled allows management via TELNET and HTTP Enable HTTP Server Mark the box to grant the specified IP addresses web based management permission Enable Telnet Server Mark the box to grant the specified IP addresses TELNET management permission Securit...

Page 77: ...ink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com IP Security interface User Authentication Use this function to change the login name and password 1 User name Enter the new user name The default is root 2 Password Enter the new password The default is root 3 Confirm password Confirm the new password 4 Click Apply User Authentication interface ...

Page 78: ...ate Enabled or Disabled Tx Good Packet Displays the number of good packets transmitted Tx Bad Packet Displays the number of bad packets transmitted Rx Good Packet Displays the number of good packets received Rx Bad Packet Displays the number of bad packets received Tx Abort Packet Displays the number of aborted transmit packets Packet Collision Displays the number of packet collisions Packet Dropp...

Page 79: ...ort Control Used to configure and view port settings 1 Port Select the port to configure 2 State Enable or disable the port 3 Negotiation Set the negotiation status of the port 4 Speed Set the port link speed 5 Duplex Set the port to full or half duplex 6 Flow Control Set flow control to Symmetric or Asymmetric in Full Duplex mode The default value is Symmetric 7 Security Set the port security Whe...

Page 80: ...s bandwidth to a device on the network LACP operation requires full duplex mode Aggregator setting 1 System Priority a value used to identify the active LACP The switch with the lowest value has the highest priority It is selected as the active LACP 2 Group ID There are four trunk groups available Choose the Group ID and click Select 3 LACP If enabled the group is an LACP static trunk group If dis...

Page 81: ...om B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 6 When LACP enabled you can configure LACP Active Passive status for each port on State Activity page 7 Click Apply 8 Use Delete to delete Trunk Group Port Trunk Aggregator setting interface four ports are added to the left field with LACP enabled ...

Page 82: ...c trunk group information Port Trunk Aggregator setting interface two ports are added to the left field with LACP disable Port Trunk Aggregator Information interface State Activity After setting up the LACP aggregator port state activity can be configured Mark the port and click Apply The port state activity will change to Active or Passive depending on its previous state Active The port automatic...

Page 83: ...nk Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com NOTE 1 A link having either two active LACP ports or one active port can perform dynamic LACP trunk 2 A link which has two passive LACP ports will not perform dynamic LACP trunk because both ports are waiting for an LACP protocol packet from the opposite device Port Trunk State Activity interface ...

Page 84: ...raffic flowing through the indicated ports can be monitored by a specified port Port Trunk Port Mirroring interface Destination Port Only one port can be selected as the destination mirror port for monitoring both RX and TX traffic from the source port Two ports may be configured to monitor RX and TX traffic separately A LAN analyzer can be connected to the mirror port Source Port Select the ports...

Page 85: ... can set up every port s frame limitation type and bandwidth rate Rate Limiting interface All the ports support port ingress and egress rate control For example assume port 1 is 10Mbps users can set its effective egress rate to 1Mbps and ingress rate is 500Kbps The switch performs the ingress rate limiting using a packet counter to meet the specified rate Ingress Enter the port effective ingress r...

Page 86: ... Layer 2 switch However the network devices retain their same physical connection The switch supports port based and 802 1Q tagged based VLAN In the default configuration the VLAN option is disabled The switch supports Port based and 802 1Q tagged based VLAN The default configuration of VLAN operation mode is Disable VLAN Configuration interface VLAN configuration Port based VLAN With port based V...

Page 87: ... 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com VLAN Port Based interface Pull down the selection item for Port Based then press Apply button Click Add to add a new VLAN group 64 groups maximum VLAN Port Based Add interface ...

Page 88: ...B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com VLAN Port Based Edit Delete interface Use Delete button to delete the VLAN Use Edit button to modify group name VLAN ID or add remove the members of the existing VLAN group NOTE If the configuration is not saved it will be lost when the port is powered off ...

Page 89: ...ame The tag contains a VLAN Identifier VID When the 802 1Q VLAN is enabled all ports on the switch belong to a default VLAN VID 1 The default VLAN cannot be deleted Up to 64 VLAN groups are supported 802 1Q Configuration 1 Enable GVRP Protocol check the check box to enable GVRP protocol 2 Select the port to configure 3 Link Type there are three link types Access Link Single switch only Allows port...

Page 90: ...awa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 802 1Q VLAN interface Group Configuration Edit the existing VLAN Group Select the VLAN group in the table list Click Edit button ...

Page 91: ...ttawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Group Configuration interface You can modify the VLAN group name and VLAN ID Group Configuration interface Click Apply button ...

Page 92: ...to identify the root bridge The bridge with the lowest value has the highest priority and is selected as the root If the value changes the switch must be rebooted The value must be multiple of 4096 Max Age 6 40 The number of seconds a bridge waits without receiving Spanning tree Protocol configuration messages before attempting a reconfiguration Enter a value between 6 through 40 Hello Time 1 10 T...

Page 93: ...t The cost of the path to the other bridge from this transmitting bridge at the specified port Enter a number 1 through 200000000 2 Priority Network priority Enter a number between 0 and 240 The value must be a multiple of 16 3 P2P Some of the rapid state transactions that are possible within RSTP are dependent upon whether the port concerned can only be connected to exactly one other bridge i e i...

Page 94: ...more Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com False is P2P disabled 4 Edge The port directly connected to the end stations cannot create a bridging loop in the network To configure the port as an edge port set the port to True status Non STP Set True to disable STP mathematic calculation Set False to including the STP mathematic calculation Click Apply RSTP Port Configur...

Page 95: ...find and solve network problems and plan for network growth Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP System Configuration Community Strings Define and remove community strings 1 String Enter the name of the string 2 RO Read only Enables requests accompanied by this string to display MIB object information 3 RW Read wri...

Page 96: ...n interface Trap Configuration A trap manager is a management station that receives traps the system alerts generated by the switch If the trap manager is not defined traps will not be issued Create a trap manager by entering the IP address of the station and a community string 1 IP Address Enter the IP address of the trap manager 2 Community Enter the community string 3 Trap Version Select the SN...

Page 97: ... europe com Trap Managers interface SNMPV3 Configuration Context Table Configure SNMP v3 context table Assign the context name of context table Click Add to add context name Click Remove to remove the unwanted context name User Profile Configure SNMP v3 user table User ID Enter the user name Authentication Password Enter the authentication password Privacy Password Enter the private password Click...

Page 98: ...ctronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com SNMP V3 configuration interface ...

Page 99: ...ck Add to add the context name Click Remove to remove an unwanted context name Access Table Configure SNMP v3 access table Context Prefix Set up the context name Group Name Set up the group Security Level Set up the access level Context Match Rule Select the context match rule Read View Name Set up the read view Write View Name Set up the write view Notify View Name Set up the notify view Click Ad...

Page 100: ...owest queue For example when processing 1 frame of the lowest queue 2 frames of the low queue 4 frames of the middle queue and 8 frames of the high queue will be processed at the same time Use the strict priority scheme The highest queue will always processed first Priority Type there are five priority selections available Port base the port priority will follow the assigned Port base High middle ...

Page 101: ...awa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com QoS Configuration interface Port based Priority Port x Each port has 4 priority levels High Middle Low and Lowest to select from ...

Page 102: ...default value is Lowest When an IP packet is received the system will check the TOS level value in the IP packet For example if the TOS level 25 is high and the port is following the TOS priority policy only when a packet is received the system will check the TOS value of the received IP packet If the TOS value of received IP packet is 25 priority high then the packet will have highest priority Cl...

Page 103: ...rt A message sent by a host to the querier to indicate that the host wants to be or is a member of a given group indicated in the report message Leave Group A message sent by a host to the querier to indicate that the host has quit being a member of a specific multicast group Enable IGMP protocol on the web management switch setting advanced page IP multicast addresses range from 224 0 0 0 through...

Page 104: ...r ports are called working ports If a network connection failure occurs the backup port will automatically become a working port to recover The switch can be set in the ring master or slave mode The ring master negotiates and places commands to the other switches in the X Ring group If there are two or more switches in the master mode the software will select the switch with lowest MAC address num...

Page 105: ...heck box to enable the coupling ring function Coupling port Assign the member port Control port Set the switch as the master switch in the coupling ring Enable Dual Homing Set up one of port on the switch to be the Dual Homing port In an X Ring group only one port can be the Dual Homing port Dual Homing only works when the X Ring function is enabled Click Apply X ring Interface NOTE 1 When the X R...

Page 106: ... to the Internet until it proves authority by providing a user name and password which is verified by a separate server System Configuration 1 IEEE 802 1x Protocol Enable or disable 802 1x protocol 2 Radius Server IP Enter the Radius Server IP address 3 Server Port Enter the UDP destination port for authentication requests to the Radius Server 4 Accounting Port Enter the UDP destination port for a...

Page 107: ...802 1x Port Configuration You can configure 802 1x authentication state for each port The State choices are Disable Accept Reject and Authorize Use the Space key change the state value Reject The port is held in the unauthorized state Accept The port is held in the Authorized state Authorized The port will allow an authentication exchange between the supplicant and the authentication server Disabl...

Page 108: ...plicant TX Period Sets the period that the port waits before retransmitting the next EAPOL PDU during an authentication session Supplicant Timeout Sets the period the switch waits for a supplicant response to an EAP request Server Timeout Set the period the switch waits for a server response to an authentication request Max Requests Sets the number of authentications that time out before authentic...

Page 109: ...le regardless of whether the device is physically connected to the switch Therefore the switch does not have to re learn a device s MAC address when the disconnected or powered off device reconnects to the network You can add modify delete a static MAC address Add the Static MAC Address You can add static MAC address in the switch MAC table here MAC Address Enter the MAC address of the port that s...

Page 110: ... Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Static MAC Addresses interface MAC Filtering MAC Filtering interface 1 MAC Address Enter the MAC address that you want to filter 2 Click Add button 3 If you want to delete the MAC address from the filtering table select the MAC address and click Delete button ...

Page 111: ...www bb europe com All MAC Addresses You can view the port that connected device s MAC address and the related devices MAC address 1 Select the port 2 The selected port static dynamic MAC address information will be displayed 3 Click Clear MAC Table to clear the port static MAC address All MAC Address interface Factory Default To reset switch to the default configuration click Reset This function h...

Page 112: ... 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Factory Default interface Save Configuration Click Save to save the configuration to the flash memory Save Configuration interface System Reboot Click Reboot to reboot the system System Reboot interface ...

Page 113: ...ting Verify that 12 to 48VDC power is available Do not exceed 48VDC Select the proper cable to construct your network Use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 100Ω Category 3 4 or 5 cable for 10Mbps connections 100Ω Category 5 cable for 100Mbps or 100Ω Category 5e above cable for 1000Mbps connections Ensure that the length of any twisted pair connectio...

Page 114: ...anning Tree IEEE 802 1w Rapid Spanning Tree IEEE 802 1p Class of Service IEEE 802 1Q VLAN Tag IEEE 802 1x User Authentication RADIUS Protocol CSMA CD Transfer Rate 14 880 pps for 10Base T Ethernet port 148 800 pps for 100Base TX FX Fast Ethernet port 1 488 000 pps for Gigabit Fiber Ethernet port MAC address 8K MAC address table Packet Buffer 1Mbits LED Per unit Power Green Power 1 Green Power 2 Gr...

Page 115: ...Multi mode 50 125um or 62 5 125um LC Single mode 9 125um Back plane 7 2Gbps Packet throughput ability 10 7Mpps at 64bytes Power Supply 12 to 48 VDC Redundant power with reverse polarity protection and removable terminal block Power Consumption 11 2 Watts Install DIN Rail and Wall Mount Design Operation Temp 40o C to 75o C Operation Humidity 5 to 95 Non condensing Storage Temperature 40o C to 85o C...

Page 116: ...5 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com CE EN61000 4 11 CE EN61000 4 12 CE EN61000 6 2 CE EN61000 6 4 Safety CE EN60950 1 Stability testing IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vibration ...

Reviews: