background image

                                                                                             

   

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com 

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com                             

       

 

 

Product Description

 

Model EIR610-3SFP-T

 

Documentation Number:    EIR610-3SFP-T_0708m 

 

 

 

 

 

 

 

 

  707 Dayton Road  --  P.O. Box 1040  --  Ottawa, IL  61350 USA 

    Phone (815) 433-5100 -- General Fax (815) 433-5105   

 

Phone

 (815) 433-5100 -- 

General Fax

 (815) 433-5105   

Website: 

www.bb-elec.com

 

Sales

 e-mail: 

[email protected]

 -- 

Fax

 (815) 433-5109 

Technical Support

 e-mail: 

[email protected]

 -- 

Fax

 (815) 433-5104 

 

 

 

European Headquarters 

B&B Electronics 

Westlink Commercial Park -- Oranmore, Co.    Galway, Ireland 

Phone

 +353 91-792444 -- 

Fax 

+353 91-792445 

Website: 

www.bb-europe.com

 

Sales

 e-mail: 

[email protected]

 

Technical Support

 e-mail: 

[email protected]

 

 

 

 

© 2008 B&B Electronics Mfg. Co. Inc.    -    Revised February 2008 

Summary of Contents for EIR610-3SFP-T

Page 1: ...Box 1040 Ottawa IL 61350 USA Phone 815 433 5100 General Fax 815 433 5105 Phone 815 433 5100 General Fax 815 433 5105 Website www bb elec com Sales e mail orders bb elec com Fax 815 433 5109 Technical Support e mail support bb elec com Fax 815 433 5104 European Headquarters B B Electronics Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 792445 Website www bb europ...

Page 2: ... 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Eight Port Managed Industrial Ethernet Switches User Manual ...

Page 3: ...with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the followin...

Page 4: ...91 792444 Fax 353 91 792445 www bb europe com Content Overview 1 Introduction 1 Features 2 Packing List 4 Hardware Description 5 Physical Dimensions W x H x D 5 Front Panel 5 Top View 6 Wiring the Power Inputs 6 Wiring the Fault Alarm Contact 7 LED Indicators 8 Ports 9 Cabling 11 Mounting Installation 14 DIN Rail Mounting 14 Panel Mounting 15 Hardware Installation 16 Installation Steps 16 ...

Page 5: ...europe com X Ring Application 17 Coupling Ring Application 18 Dual Homing Application 18 Console Management 19 Connecting to the Console Port 19 Pin Assignment 19 Login in the Console Interface 20 CLI Management 21 Commands Level 22 Commands Set List 23 System Commands Set 23 Port Commands Set 26 Trunk Commands Set 28 VLAN Commands Set 29 Spanning Tree Commands Set 31 QOS Commands Set 34 IGMP Comm...

Page 6: ...MTP and Event Commands Set 42 SNTP Commands Set 43 X ring Commands Set 44 Web Based Management 46 About Web based Management 46 Preparing for Web Management 46 System Login 46 Main interface 47 System Information 48 IP Configuration 48 DHCP Server System configuration 49 DHCP Client Entries 50 DHCP Server Port and IP Bindings 50 TFTP Update Firmware 51 TFTP Restore Configuration 52 TFTP Backup Con...

Page 7: ...792444 Fax 353 91 792445 www bb europe com System Event Log Event Configuration 55 Fault Relay Alarm 57 SNTP Configuration 57 IP Security 60 User Authentication 61 Digital Input Output 62 Port Statistics 63 Port Control 64 Port Trunk 65 Aggregator setting 65 Aggregator Information 66 State Activity 67 Port Mirroring 68 Rate Limiting 69 VLAN configuration 70 VLAN configuration Port based VLAN 70 80...

Page 8: ...RSTP Port Configuration 77 SNMP Configuration 78 System Configuration 78 Trap Configuration 79 SNMPV3 Configuration 80 QoS Configuration 83 QoS Policy and Priority Type 83 Port Base Priority 84 COS Configuration 85 TOS Configuration 85 IGMP Configuration 85 X Ring 87 Security 89 802 1X Radius Configuration 89 MAC Address Table 92 Factory Default 95 Save Configuration 95 System Reboot 95 Trouble sh...

Page 9: ...provides an easy way to establish a redundant Ethernet network With ultra high speed recovery time less than 300 ms and a long MTBF Mean Time Between Failures the industrial switch will continue to operate until a Gigabit network infrastructure has been established without requiring extra upgrade costs In addition to10 100 1000Base TX fast Ethernet ports the switch has SFP mini GBIC ports Traditio...

Page 10: ...S protection 4 000 VDC Power Supply Wide range Redundant Power Design Reverse Polarity Protection Overload Current Protection Case Installation IP 30 Protection DIN Rail and Panel Mount Design Spanning Tree IEEE802 1d Spanning Tree IEEE802 1w Rapid Spanning Tree VLAN Port Based VLAN 802 1 Q Tag VLAN GVRP X Ring X Ring Dual Homing Couple Ring and Dual Ring Topology Provide redundant backup feature ...

Page 11: ...ope com Both of TX and RX Packet System Event Log System Log Server Client SMTP e mail Alert Relay Alarm Output System Events Security Port Security MAC address entries filter IP Security IP address security management to prevent intrusion Login Security IEEE802 1X RADIUS SNMP Trap Cold Start Power Status Authentication Failure X Ring topology Change Link up Link down IGMP with Query mode for Mult...

Page 12: ... 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Packing List 1 x Managed Industrial Switch 1 x RS 232 DB9 to RJ 45 adapter 1 x CD Rom with this user manual 2 x Mounting Bracket and Screws ...

Page 13: ... Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Hardware Description Physical Dimensions W x H x D 2 7 x 4 2 x 6 4 in 7 4 x 10 7 x 16 3 cm Front Panel ...

Page 14: ...Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Top View Wiring the Power Inputs Insert the positive and negative leads into the V and V contacts on the terminal block connector Tighten the wire clamp screws Note Use 12 to 14 AWG wire ...

Page 15: ...lectronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Insert the wires into the fault alarm contact Wiring the Fault Alarm Contact NOTE Use 12 to 24 AWG wire NOTE Relay contacts are normally closed NOTE The Relay Alarm also requires software configuration Refer to the Web Based Management Fault Relay Alarm Section ...

Page 16: ...reen Power Source 1 available Off Power Source 1 unavailable PWR2 Green Power Source 2 available Off Power Source 2 unavailable Fault Red Power failure or port failure Off Normal Operation R M Green The switch is the master of the X Ring group Off The switch is not a ring master in the X Ring group LNK ACT for P9 P10 SFP Green SFP port is linked Blinks Networking is active Off No device attached P...

Page 17: ...d or not operating at speed of 1000M P1 P8 Green Upper LED Network device detected Blinking Upper LED Network is active Off Upper LED No device attached Yellow Lower LED The port is operating in full duplex mode Blinking Lower LED Data packet collision Off Lower LED The port is in half duplex mode or no device attached Ports RJ 45 ports Auto MDI MDIX The RJ 45 ports are auto sensing for 10Base T 1...

Page 18: ... Figure below for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The 10BASE T 100BASE TX 1000BASE T MDI and MDI X port pin outs are as tabled below Pin MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmit Data plus ...

Page 19: ...e or above cabling for RJ 45 port connection The cable between the switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft long The small form factor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunication and data communication applications Follow these steps to connect the transceiver and LC Cable First insert th...

Page 20: ...tlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Second insert the fiber cable of LC connector into the transceiver LC connector to the transceiver To remove the LC connector from the transceiver follow the steps shown below First press the upper side of the LC connector from the transceiver and pull it out to release Remove LC connector ...

Page 21: ...x 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Second push down the metal loop and pull the transceiver out by the plastic part Pull out from the SFP module ...

Page 22: ...n Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Mounting Installation DIN Rail Mounting 1 First insert the top of DIN Rail into the track ...

Page 23: ...utton of DIN Rail into the track 3 Ensure the DIN Rail is tightly on the track 4 To remove the industrial switch from the track reverse the steps above Panel Mounting Follow the steps as below to mount the industrial switch with wall mount plate 1 Remove the DIN Rail from the industrial switch 2 Place the panel mount plate on the rear panel 3 Use the screws to attach the panel mount 4 Use the hook...

Page 24: ...ation Steps 1 Unpack the Industrial switch 2 Ensure the DIN Rail is tightly screwed to the Industrial switch If not refer to DIN Rail Mounting section for DIN Rail installation To panel mount the Industrial switch refer to Panel Mounting section 3 Apply power to the switch refer to the Wiring the Power Inputs section The power LED will light 4 Connect CAT 5 cables to the Industrial switch s RJ 45 ...

Page 25: ...t the switch s fiber optic transmitter is connected to the network devices receiver and vice versa 6 Connect the fiber optic cables 7 When all the connections are made and the LEDs show normal indications the installation is complete X Ring Application This switch incorporates the X Ring Protocol to ensure network reliability and system restoration within 300 ms in the event of a connection failur...

Page 26: ...ng function is used to connect them and add redundancy This ensures that transmissions between the two ring groups will not fail The figure below is an example of the coupling ring application Dual Homing Application The Dual Homing function is used to prevent a connection loss between the X Ring group and the upper level core switch Assign a port in each X ring group to be the Dual Homing ports T...

Page 27: ...e Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Console Management Connecting to the Console Port Attach the DB9 end to a PC or terminal and the RJ 45 end to the console port on the switch The PC must have support a terminal emulation program Pin Assignment DB9 Connector RJ 45 Connector NC 1 Orange White 2 2 Orange 3 3 Green White NC 4 Blue 5 5 Blue White NC 6 Green NC 7 Brow...

Page 28: ...Login in the Console Interface When the connection between Switch and PC is ready turn on the PC run a terminal emulation program or Hyper Terminal and configure the following communication parameters Baud Rate 9600 bps Data Bits 8 Parity none Stop Bit 1 Flow control None The settings of communication parameters After entering the parameter click OK When the blank screen shows up press Enter on th...

Page 29: ...0 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Console login interface CLI Management After you login to the system you will see a command prompt To enter CLI management interface type enable and press enter CLI command interface ...

Page 30: ...tem information Privileged EXEC Enter the enable command while in user EXEC mode switch Enter disable to exit The privileged command is advance mode Privileged this mode to Displays advance function status Save configures Global Configuration Enter the configure command while in privileged EXEC mode switch config To exit to privileged EXEC mode enter exit or end Use this mode to configure paramete...

Page 31: ...ig show terminal P Show console information switch show terminal write memory P Save user configuration into permanent memory flash ROM switch write memory system name System Name G Configure system name switch config system name xxx system location System Location G Set switch system location string switch config system location xxx system description System Description G Set switch system descri...

Page 32: ... show admin P Show administrator information switch show admin dhcpserver enable G Enable DHCP Server switch config dhcpserver enable Dhcpserver disable G Disable DHCP Server switch config no dhcpserver dhcpserver lowip Low IP G Configure low IP address for IP pool switch config dhcpserver lowip 192 168 1 100 dhcpserver highip High IP G Configure high IP address for IP pool switch config dhcpserve...

Page 33: ...ch show dhcpserver ip binding no dhcpserver G Disable DHCP server function switch config no dhcpserver security enable G Enable IP security function switch config security enable security http G Enable IP security of HTTP server switch config security http security telnet G Enable IP security of telnet server switch config security telnet security ip Index 1 10 IP Address G Set the IP security lis...

Page 34: ...ig interface fastEthernet 2 switch config if duplex full speed 10 100 1000 auto I Use the speed configuration command to specify the speed mode of operation for Fast Ethernet the speed can t be set to 1000 if the port isn t a giga port switch config interface fastEthernet 2 switch config if speed 100 no flowcontrol I Disable flow control of interface switch config if no flowcontrol security enable...

Page 35: ...e fastEthernet 2 switch config if bandwidth type broadcast multicast bandwidth type broadcast only I Set interface ingress limit frame type to only accept broadcast frame switch config interface fastEthernet 2 switch config if bandwidth type broadcast only bandwidth in Value I Set interface input bandwidth Rate Range is from 100 kbps to 102400 kbps or to 256000 kbps for giga ports and zero means n...

Page 36: ...erface actual status switch config interface fastEthernet 2 config if show interface status show interface accounting I show interface statistic counter switch config interface fastEthernet 2 config if show interface accounting no accounting I Clear interface accounting information switch config interface fastEthernet 2 switch config if no accounting Trunk Commands Set Commands Level Description E...

Page 37: ...rt list nolacp G Assign a static trunk group GroupID 1 4 Port list Member port list This parameter could be a port range ex 1 4 or a port list separate by a comma ex 2 3 6 switch config aggregator group 1 2 4 nolacp or switch config aggregator group 1 3 1 2 nolacp show aggregator P Show the information of trunk group switch show aggregator 1 or switch show aggregator 2 or switch show aggregator 3 ...

Page 38: ... vlan port based grpname test grpid 2 port 2 3 4 show vlan GroupID or show vlan V Show VLAN information switch vlan show vlan 23 no vlan group GroupID V Delete port base group ID switch vlan no vlan group 2 IEEE 802 1Q VLAN vlan 8021q name GroupName vid VID V Change the name of VLAN group if the group didn t exist this command can t be applied switch vlan vlan 8021q name test vid 22 vlan 8021q por...

Page 39: ...link tag TaggedVID List V Assign a trunk link for VLAN by trunk group switch vlan vlan 8021q trunk 3 trunk link tag 2 3 6 99 or switch vlan vlan 8021q trunk 3 trunk link tag 3 20 vlan 8021q trunk PortNumber hybrid link untag UntaggedVID tag TaggedVID List V Assign a hybrid link for VLAN by trunk group switch vlan vlan 8021q trunk 3 hybrid link untag 4 tag 3 6 8 or switch vlan vlan 8021q trunk 3 hy...

Page 40: ...age from the root switch within this interval it recomputed the Spanning Tree Protocol STP topology spanning tree hello time seconds G Use the spanning tree hello time global configuration command to specify the interval between hello bridge protocol data units BPDUs switch config spanning tree hello time 3 spanning tree forward time seconds G Use the spanning tree forward time global configuratio...

Page 41: ... when selecting an interface to place into the forwarding state switch config interface fastEthernet 2 switch config if stp path cost 20 stp path priority Port Priority I Use the spanning tree port priority interface configuration command to configure a port priority that is used when two switches tie for position as the root switch switch config interface fastEthernet 2 switch config if stp path ...

Page 42: ...hted fair strict G Select QOS policy scheduling switch config qos policy weighted fair qos prioritytype port based cos only tos only cos first tos first G Setting of QOS priority type switch config qos prioritytype qos priority portbased Port lowest low middle high G Configure Port based Priority switch config qos priority portbased 1 low qos priority cos Priority lowest low mid dle high G Configu...

Page 43: ...tch no igmp query Mac Filter Table Commands Set Commands Level Description Example mac address table static hwaddr MAC I Configure MAC address table of interface static switch config interface fastEthernet 2 switch config if mac address tab le static hwaddr 000012345678 mac address table filter hwaddr MAC G Configure MAC address table filter switch config mac address table filter hwaddr 0000123486...

Page 44: ...m Location G Set SNMP agent system location switch config snmp system location lab snmp system contact System Contact G Set SNMP agent system contact switch config snmp system contact where snmp agent mode v1v2c v3 v1v2cv3 G Select the agent mode of SNMP switch config snmp agent mode v1v2cv3 snmp community strings Community right RO RW G Add SNMP community string switch config snmp community strin...

Page 45: ...d View Name Write View Name Notify View Name G Configure the access table of SNMPV3 agent switch config snmpv3 access context name Test group G1 security level AuthPriv match rule Exact views V1 V1 V1 snmpv3 mibview view View Name type Excluded Included sub oid OID G Configure the mibview table of SNMPV3 agent switch config snmpv3 mibview view V1 type Excluded sub oid 1 3 6 1 show snmp P Show SNMP...

Page 46: ...of SNMPv3 agent switch config no snmpv3 access context name Test group G1 security level AuthPr iv match rule Exact views V1 V1 V1 no snmpv3 mibview view View Name type Excluded Included sub oid OID G Remove specified mibview table of SNMPV3 agent switch config no snmpv3 mibview view V1 type Excluded sub oid 1 3 6 1 Port Mirroring Commands Set Commands Level Description Example monitor rx G Set RX...

Page 47: ...ble G Use the 802 1x global configuration command to enable 802 1x protocols switch config 8021x enable 8021x system radiusip IP address G Use the 802 1x system radius IP global configuration command to change the radius server IP switch config 8021x system radiusip 192 168 1 1 8021x system serverport port ID G Use the 802 1x system server port global configuration command to change the radius ser...

Page 48: ...fig 8021x misc quietperiod 10 8021x misc txperiod sec G Use the 802 1x misc TX period global configuration command to set the TX period switch config 8021x misc txperiod 5 8021x misc supportimeout sec G Use the 802 1x misc supp timeout global configuration command to set the supplicant timeout switch config 8021x misc supportimeout 20 8021x misc servertimeout sec G Use the 802 1x misc server timeo...

Page 49: ...x portstate accept show 8021x E Displays a summary of the 802 1x properties and also the port sates switch show 8021x no 8021x G Disable 802 1x function switch config no 8021x TFTP Commands Set Commands Level Description Defaults Example backup flash backup_cfg G Save configuration to TFTP and need to specify the IP of TFTP server and the file name of image switch config backup flash backup_cfg re...

Page 50: ...SMTP function switch config smtp enable smtp serverip IP address G Configure SMTP server IP switch config smtp serverip 192 168 1 5 smtp authentication G Enable SMTP authentication switch config smtp authentication smtp account account G Configure authentication account switch config smtp account User smtp password password G Configure authentication password switch config smtp password smtp rcpte...

Page 51: ...sable cold start event type switch config no event device cold start no event authentication failure G Disable Authentication failure event typ switch config no event authentication failure no event X ring topology change G Disable X ring topology changed event type switch config no event X ring topology change no event systemlog I Disable port event for system log switch config interface fastethe...

Page 52: ...t offset Minute G Set offset of daylight saving time if SNTP function is inactive this command can t be applied switch config sntp daylight offset 3 sntp ip IP G Set SNTP server IP if SNTP function is inactive this command can t be applied switch config sntp ip 192 169 1 1 sntp timezone Timezone G Set timezone index use show sntp timzezone command to get more information of index number switch con...

Page 53: ...g dualhoming Xring ringport 1st Ring Port 2nd Ring Port G Configure 1st 2nd Ring Port switch config Xring ringport 7 8 Xring couplingport Coupling Port G Configure Coupling Port switch config Xring couplingport 1 Xring controlport Control Port G Configure Control Port switch config Xring controlport 2 Xring homingport Dual Homing Port G Configure Dual Homing Port switch config Xring homingport 3 s...

Page 54: ...om anywhere on the network The web site is designed for Internet Explorer 6 0 and uses Java Applets to reduce bandwidth consumption enhance access speed and present an intuitive user interface Preparing for Web Management Before using web management install the industrial switch on the network and verify that a PC on the local network can connect with the switch through the web browser The default...

Page 55: ... 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 3 The login screen will appear 4 Enter the user name and password The default user name and password are root 5 Press Enter or OK and then the home screen will appear Login screen Main interface Main interface ...

Page 56: ...version MAC Address Displays the unique hardware address assigned by manufacturer default IP Configuration Configure the IP Settings and DHCP client function DHCP Client Used to enable or disable the DHCP client function When enabled the switch s IP address is assigned by the network DHCP server The default IP address will be replace by the DHCP server assigned IP address After clicking the Apply ...

Page 57: ...tem configuration The switch can function as a DHCP server DHCP Server Enable or Disable the DHCP Server function Low IP Address the dynamic IP assign range Low IP address is the beginning of the dynamic IP assignment range High IP Address the dynamic IP assign range High IP address is the end of the dynamic IP assignment range Subnet Mask The subnet mask Gateway The network gateway DNS Network Do...

Page 58: ...y Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com DHCP Server Configuration interface DHCP Client Entries DHCP client information is displayed DHCP Client Entries interface DHCP Server Port and IP Bindings You can assign a specific IP address that is in the dynamic IP assignment range to the specific port When the device is connected to the port and asks for an assignment the system w...

Page 59: ...ore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Port and IP Bindings interface TFTP Update Firmware Provides the ability to update the switch s firmware Before updating ensure you the TFTP server is ready and the firmware image is on the TFTP server 1 TFTP Server IP Address Enter the TFTP server IP 2 Firmware File Name Enter the name of firmware image 3 Click Apply Update F...

Page 60: ...europe com TFTP Restore Configuration If the EEPROM image is stored on the TFTP server you can restore it to flash memory 1 TFTP Server IP Address Enter the TFTP server IP 2 Restore File Name Enter the restore file name 3 Click Apply Restore Configuration interface TFTP Backup Configuration You can save current EEPROM image to the TFTP server 1 TFTP Server IP Address Enter the TFTP server IP 2 Bac...

Page 61: ... Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com System Event Log Syslog Configuration 1 Syslog Client Mode Select the system log mode client only server only or both 2 System Log Server IP Address Assigned the system log server IP 3 Click Reload to refresh the events log 4 Click Clear to clear all current events log 5 After configuring Click Apply Syslog Configuration...

Page 62: ... 1 Email Alert enable or disable the email alert function 2 SMTP Server IP set up the mail server IP address 3 Sender Enter the email address e g switch102 123 com to identify where the event log came from 4 Authentication Mark the check box to enable and configure the email account and password for authentication 5 Mail Account set up the email account e g johnadmin for the switch It must be an e...

Page 63: ...353 91 792444 Fax 353 91 792445 www bb europe com SMTP Configuration interface System Event Log Event Configuration When the selected events occur the system will generate a log entry and email notification message System event selection Four selections available Cold Start Warm Start SNMP Authentication Failure and X ring topology change Mark the checkbox to select the event When the selected eve...

Page 64: ...04 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Event Configuration interface Port event selection When a port specific event occurs the system will generate a log entry and email notification Three selections are available Link UP Link Down and Link UP Link Down ...

Page 65: ...ower Failure When the check box is marked the Fault LED will light if the power source fails Port Link Down Broken When the check box is marked the Fault LED will light if a port link goes down Fault Relay Alarm interface SNTP Configuration The SNTP allows you to synchronize switch clocks 1 SNTP Client Enables or disables the SNTP function 2 Daylight Saving Time Enables or disables daylight saving...

Page 66: ...Atlantic Daylight 3 hours 9 am AST Atlantic Standard EDT Eastern Daylight 4 hours 8 am EST Eastern Standard CDT Central Daylight 5 hours 7 am CST Central Standard MDT Mountain Daylight 6 hours 6 am MST Mountain Standard PDT Pacific Daylight 7 hours 5 am PST Pacific Standard ADT Alaskan Daylight 8 hours 4 am ALA Alaskan Standard 9 hours 3 am HAW Hawaiian Standard 10 hours 2 am Nome Alaska 11 hours ...

Page 67: ...6 hours 6 pm WAST West Australian Standard 7 hours 7 pm CCT China Coast Russia Zone 7 8 hours 8 pm JST Japan Standard Russia Zone 8 9 hours 9 pm EAST East Australian Standard GST Guam Standard Russia Zone 9 10 hours 10 pm IDLE International Date Line NZST New Zealand Standard NZT New Zealand 12 hours Midnight 4 SNTP Sever URL Enter the SNTP server IP address 5 Daylight Saving Period Enter the Dayl...

Page 68: ...urity function grants 10 specific IP addresses permission to access the switch through a web browser or TELNET for management IP Security Mode When enabled allows management via TELNET and HTTP Enable HTTP Server Mark the box to grant the specified IP addresses web based management permission Enable Telnet Server Mark the box to grant the specified IP addresses TELNET management permission Securit...

Page 69: ...ink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com IP Security interface User Authentication Use this function to change the login name and password 1 User name Enter the new user name The default is root 2 Password Enter the new password The default is root 3 Confirm password Confirm the new password 4 Click Apply User Authentication interface ...

Page 70: ...hich can be applied to heaters pumps and other electrical equipment The digital inputs may be read by the host computer and used to sense the state of a remote digital signal The Digital Input Output function must software enabled to be available This is accomplished via a pull down box on the web interface Digital Input Choose the transition type to trigger it LowÆHigh DI0 DI1 will report the sta...

Page 71: ... State Enabled or Disabled Tx Good Packet Displays the number of good packets transmitted Tx Bad Packet Displays the number of bad packets transmitted Rx Good Packet Displays the number of good packets received Rx Bad Packet Displays the number of bad packets received Tx Abort Packet Displays the number of aborted transmit packets Packet Collision Displays the number of packet collisions Packet Dr...

Page 72: ...Used to configure and view port settings 1 Port Select the port to configure 2 State Enable or disable the port 3 Negotiation Set the negotiation status of the port 4 Speed Set the port link speed 5 Duplex Set the port to full or half duplex 6 Flow Control Set flow control to Symmetric or Asymmetric in Full Duplex mode The default value is Symmetric 7 Security Set the port security When On is sele...

Page 73: ...e Aggregator setting 1 System Priority a value used to identify the active LACP The switch with the lowest value has the highest priority It is selected as the active LACP 2 Group ID There are three trunk groups available to configure Choose the Group ID and click Select 3 LACP If enabled the group is an LACP static trunk group If disabled the group is local static trunk group All ports support LA...

Page 74: ...ax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 8 Use Delete button to delete Trunk Group Port Trunk Aggregator Setting interface Aggregator Information Displays static trunk group information Port Trunk Aggregator Information interface ...

Page 75: ...gured Mark the port and click Apply The port state activity will change to Active or Passive depending on its previous state Active The port automatically sends LACP protocol packets Passive The port responds only if it receives LACP protocol packets from the opposite device Note 1 A link having either two active LACP ports or one active port can perform dynamic LACP trunk 2 A link which has two p...

Page 76: ...raffic flowing through the indicated ports can be monitored by a specified port Destination Port Only one port can be selected as the destination mirror port for monitoring both RX and TX traffic from the source port Two ports may be configured to monitor RX and TX traffic separately A LAN analyzer can be connected to the mirror port Source Port Select the ports to monitor All monitored port traff...

Page 77: ...me type to filter There are four options All Broadcast Multicast Flooded Unicast Broadcast Multicast and Broadcast only Egress Limit The egress rate limit is ALL Rate Limiting interface All the ports support port ingress and egress rate control For example assume port 1 is 10Mbps users can set its effective egress rate to 1Mbps and ingress rate is 500Kbps The switch performs the ingress rate limit...

Page 78: ...cal equivalent of reconnecting a group of devices to another Layer 2 switch However the network devices retain their same physical connection The switch supports port based and 802 1Q tagged based VLAN In the default configuration the VLAN option is disabled VLAN Configuration interface VLAN configuration Port based VLAN With port based VLAN the port is assigned to a VLAN Therefore all devices att...

Page 79: ...3 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com VLAN Port Based interface Click Add to add a new VLAN group The maximum number of VLAN Groups is 64 Entering the VLAN name group ID and the members of VLAN group Click Apply ...

Page 80: ...delete an unwanted VLAN Use Edit button to modify an existing VLAN group Note If the configuration is not saved it will be lost when the switch is powered off 802 1Q VLAN Tagged based VLAN is an IEEE 802 1Q specification which allows VLANs to be created across devices from different venders IEEE 802 1Q VLAN uses a technique to insert a tag into the Ethernet frame The tag contains a VLAN Identifier...

Page 81: ...interface 802 1Q Configuration 1 Enable GVRP Protocol check the check box to enable GVRP protocol 2 Select the port to configure 3 Link Type there are three link types Access Link Single switch only Allows ports to be grouped by setting the same VID Trunk Link Extended application of Access Link Allows ports to be grouped by setting the same VID on two or more switches Hybrid Link Both Access Link...

Page 82: ...5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 6 Click Apply Group Configuration Edit the existing VLAN Group 1 Select the VLAN group in the table list 2 Click Apply Group Configuration interface 3 The VLAN group name and VLAN ID can be changed 4 Click Apply ...

Page 83: ...g tree convergence after a topology change The switch will auto detect a device that is running STP or RSTP protocol RSTP System Configuration RSTP state can be modified After modification click Apply RSTP mode Enable or disable the RSTP Priority 0 61440 a value used to identify the root bridge The bridge with the lowest value has the highest priority and is selected as the root If the value chang...

Page 84: ...10 The time that controls when the switch sends out the BPDU packet to check RSTP status Enter a value between 1 and 10 Forward Delay Time 4 30 the number of seconds a port waits before changing from its Rapid Spanning Tree Protocol learning and listening state to the forwarding state Enter a value between 4 and 30 Note Follow this rule to configure the MAX Age Hello Time and Forward Delay Time 2 ...

Page 85: ...etween 0 and 240 The value must be a multiple of 16 3 P2P Some of the rapid state transactions that are possible within RSTP are dependent upon whether the port concerned can only be connected to exactly one other bridge i e it is served by a point to point LAN segment or can be connected to two or more bridges i e it is served by a shared medium LAN segment This function allows the P2P status of ...

Page 86: ...kstations routers switches hubs etc on an IP network SNMP enables network administrators to manage network performance find and solve network problems and plan for network growth Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP System Configuration Community Strings Define and remove community strings 1 String Enter the name o...

Page 87: ...ion that you want to use and click Change SNMP System Configuration interface Trap Configuration A trap manager is a management station that receives traps the system alerts generated by the switch If the trap manager is not defined traps will not be issued Create a trap manager by entering the IP address of the station and a community string 1 IP Address Enter the IP address of the trap manager 2...

Page 88: ...x 353 91 792445 www bb europe com Trap Managers interface SNMPV3 Configuration Context Table Configure SNMP v3 context table Assign the context name of context table Click Add to add context name Click Remove to remove an unwanted context name User Profile Configure SNMP v3 user table User ID Enter the user name Authentication Password Enter password Privacy Password Enter the private password Cli...

Page 89: ...ctronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com SNMP V3 configuration interface ...

Page 90: ...group name Click Add Click Remove to remove an unwanted context name Access Table Configure SNMP v3 access table Context Prefix Enter the context name Group Name Enter the group Security Level Enter the access level Context Match Rule Select the context match rule Read View Name Set up the read view Write View Name Set up the write view Notify View Name Set up the notify view Click Add Click Remov...

Page 91: ...when processing 1 frame of the lowest queue 2 frames of the low queue 4 frames of the middle queue and 8 frames of the high queue will be processed at the same time Use the strict priority scheme The highest queue will always processed first Priority Type there are five priority selections available Port base the port priority will follow the assigned Port base High middle low or lowest COS Only t...

Page 92: ...ttawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com QoS Configuration interface Port Base Priority Port Each port has four priority levels High Middle Low and Lowest Click Apply ...

Page 93: ...t value is Lowest When an IP packet is received the system will check the TOS level value in the IP packet For example if the TOS level 25 is high and the port is following the TOS priority policy only when a packet is received the system will check the TOS value of the received IP packet If the TOS value of received IP packet is 25 priority high then the packet will have highest priority Click Ap...

Page 94: ...Report A message sent by a host to the querier to indicate that the host wants to be or is a member of a given group indicated in the report message Leave Group A message sent by a host to the querier to indicate that the host has quit being a member of a specific multicast group Enable IGMP protocol on the web management switch setting advanced page IP multicast addresses range from 224 0 0 0 thr...

Page 95: ... are called working switches and their two member ports are called working ports If a network connection failure occurs the backup port will automatically become a working port to recover The switch can be set in the ring master or slave mode The ring master negotiates and places commands to the other switches in the X Ring group If there are two or more switches in the master mode the software wi...

Page 96: ...ling Ring Mark the check box to enable the coupling ring function Coupling port Assign the member port Control port Set the switch as the master switch in the coupling ring Enable Dual Homing Set up one of port on the switch to be the Dual Homing port In an X Ring group only one port can be the Dual Homing port Dual Homing only works when the X Ring function is enabled Click Apply X ring Interface...

Page 97: ...switch but prevents the client from gaining access to the Internet until it proves authority by providing a user name and password which is verified by a separate server System Configuration 1 IEEE 802 1x Protocol Enable or disable 802 1x protocol 2 Radius Server IP Enter the Radius Server IP address 3 Server Port Enter the UDP destination port for authentication requests to the Radius Server 4 Ac...

Page 98: ...2 1x System Configuration interface 802 1x Port Configuration You can configure 802 1x authentication state for each port The State choices are Disable Accept Reject and Authorize Use the Space key change the state value Reject The port is held in the unauthorized state Accept The port is held in the Authorized state Authorized The port will allow an authentication exchange between the supplicant ...

Page 99: ...he port does not try to acquire a supplicant 2 TX Period Sets the period that the port waits before retransmitting the next EAPOL PDU during an authentication session 3 Supplicant Timeout Sets the period the switch waits for a supplicant response to an EAP request 4 Server Timeout Set the period the switch waits for a server response to an authentication request 5 Max Requests Sets the number of a...

Page 100: ...ess You can add a static MAC address This address remains in the switch s address table regardless of whether the device is physically connected to the switch Therefore the switch does not have to re learn a device s MAC address when the disconnected or powered off device reconnects to the network You can add modify delete a static MAC address Add the Static MAC Address 1 MAC Address Enter the MAC...

Page 101: ...c com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com MAC address and click Delete Static MAC Addresses interface MAC Filtering MAC Filtering interface 1 MAC Address Enter the MAC address that you want to filter 2 Click Add 3 If you want to delete the MAC address from filtering table select the ...

Page 102: ...com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com MAC address and click Delete All MAC Addresses 1 Select the port 2 The selected port of static MAC address information is displayed 3 Click Clear MAC Table to clear the port static MAC address information on the screen All MAC Address interface ...

Page 103: ...e Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Factory Default This resets the switch to the default configuration with the option of retaining the current IP address and user name password Click Reset Factory Default interface Save Configuration Saves configurations made to the system Click Save Save Configuration interface System Reboot Reboot the switch Click Reboot Syste...

Page 104: ...ting Verify that 12 to 48VDC power is available Do not exceed 48VDC Select the proper cable to construct your network Use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 100Ω Category 3 4 or 5 cable for 10Mbps connections 100Ω Category 5 cable for 100Mbps or 100Ω Category 5e above cable for 1000Mbps connections Ensure that the length of any twisted pair connectio...

Page 105: ...ith LACP IEEE 802 1d Spanning Tree IEEE 802 1w Rapid Spanning Tree IEEE 802 1p Class of Service IEEE 802 1Q VLAN Tag IEEE 802 1x User Authentication RADIUS IEEE 802 1ab LLDP Protocol CSMA CD Transfer Rate 14 880 pps for 10Base T Ethernet port 148 800 pps for 100Base TX FX Fast Ethernet port 1 488 000 pps for Gigabit Fiber Ethernet port MAC address 8K MAC address table Packet Buffer 1Mbits LED Per ...

Page 106: ...ptical cable LC Multi mode 50 125um or 62 5 125um LC Single mode 9 125um Back plane 7 2Gbps Packet throughput ability 10 7Mpps at 64bytes Power Supply 12 48 VDC Redundant power with polarity reverse protection and removable terminal block The power supply should meet the document listed by UL and its output must comply with L P S Power Consumption 11 2 Watts Install DIN Rail and Wall Mount Design ...

Page 107: ...and Ph 353 91 792444 Fax 353 91 792445 www bb europe com CE EN61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 CE EN61000 4 11 CE EN61000 4 12 CE EN61000 6 2 CE EN61000 6 4 Safety UL cUL CE EN60950 1 Stability testing IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vibration Relay Alarm Relay output for port breakdown and power source failure Alarm Relay Contact Rating ...

Reviews: