background image

BAMOWIZ OX 452

Dissolved oxygen monitor

Code : 452 001

USER MANUAL

OXY

09-11-2021

M-452.01-EN-AA

452-01

/1

Dissolved oxygen monitor

BAMOWIZ OX 452

22, Rue de la Voie des Bans · Z.I. de la gare · 95100 ARGENTEUIL

Tel

Fax

+33 (0)1 30 25 83 20

+33 (0)1 34 10 16 05

Web

E-mail

www.bamo.eu

[email protected]

INTERNATIONAL

Summary of Contents for BAMOWIZ OX 452

Page 1: ...01 USER MANUAL OXY 09 11 2021 M 452 01 EN AA 452 01 1 Dissolved oxygen monitor BAMOWIZ OX 452 22 Rue de la Voie des Bans Z I de la gare 95100 ARGENTEUIL Tel Fax 33 0 1 30 25 83 20 33 0 1 34 10 16 05 W...

Page 2: ...TION mode or MODIFICATION mode 10 3 11 SCREEN SAVER 11 12 OXYGEN MONITORING SETTINGS 12 12 OXYGEN CALIBRATION 13 13 SETTINGS OF INPUTS 1 2 13 1 13 SETTING A LEVEL MEASUREMENT 13 2 14 SETTING A CHANNEL...

Page 3: ...s is used to simulate the operating process The BAMOWIZ OX 452 has two more inputs 2 wire 4 20 mA signal 12 V DC power supplied to transmitters One of the 3 measurements can be transmitted to a remote...

Page 4: ...tential free Adjustable thresholds 1 to 8 trigger points to be assigned to 2 or 3 relays Switching power 3 A 250 V AC Adjustable hysteresis From 0 to 100 Adjustable timer From 0 to 9999 seconds Other...

Page 5: ...m screws Caution Do not drill the housing OXY 09 11 2021 M 452 01 EN AA 452 01 5 Dissolved oxygen monitor BAMOWIZ OX 452 22 Rue de la Voie des Bans Z I de la gare 95100 ARGENTEUIL Tel Fax 33 0 1 30 25...

Page 6: ...3 diagram on next page Input Nr 2 4 20 mA Pressure transmitter and or power to transmitter 12 V DC 2 wire 0 20 mA input load 50 Salinity transmitter Important Pressure and or salinity compensation For...

Page 7: ...OWIZ Power to transmitters 12V DC input load 50 Caution Maximum 1 Watt for both inputs Input 1 or 2 Input 1 or 2 OXY 09 11 2021 M 452 01 EN AA 452 01 7 Dissolved oxygen monitor BAMOWIZ OX 452 22 Rue d...

Page 8: ...PLAY Viewing assigned alarms Access to alphanumeric display A graphic is available for each connected transmitter Press the right arrow to access the different graphics OXY 09 11 2021 M 452 01 EN AA 4...

Page 9: ...n for choosing the secundary chart Note that the scaling will be that of the main chart Pic C The selected charts are displayed on the screen 3 Setting the period scale Pic D Use the keys and to decre...

Page 10: ...well as ENTER function ARROWS Cursors to navigate within the menus OFF ON To disable OFF or enable ON setting s SAVE To save the settings ESCAPE To cancel modification s RELAY STATUS S1 S2 S3 Display...

Page 11: ...r BAMOWIZ is on the sticker on side of the unit You can find it as well through the menu SETTINGS From the main screen go to MENU Press the padlock icon and type the last four numbers of S N Pressing...

Page 12: ...channel Note If the dissolved oxygen probe BAMOX 453 is disconnected BAMOWIZ will show an alert by a flashing red error message 12 OXYGEN CALIBRATION The BAMOX 453 probe is calibrated at the factory h...

Page 13: ...ect the unit for the numeric display m cm mm or Screen N 2 Select the unit for Bar Graphical display m cm mm or Press RETURN then SAVE to record all settings Example Use of an hydrostatique level tran...

Page 14: ...all parameters according your tank Screen N 1 Select the unit for the numeric display m cubic metre or l litre Screen N 2 Select the unit for graphical display m cubic metre or l litre Press RETURN th...

Page 15: ...ent value is higher than threshold Note The REST setpoint will be lower than the EXCITED setpoint See graph below Decreasing Relay actuates when measurement value is lower than threshold Note The REST...

Page 16: ...nput Push on Reset to erase the Max Min values for each necessary input NOTE On graphical display Max Min values may be displayed or hidden on request 18 CHOOSE THE COLOURS This setting is accessible...

Reviews: