background image

 

 

INSTALLATION AND MAINTENANCE 

MANUAL FOR  

BA-440 DUALBEAM BARCODE READER 

 
 
 
 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
 
 

revised 3/29/2012

 

 

800-528-9167 
407-327-2177 

FAX 407-327-6172 

Post Office Box 195268 

Winter Springs, FL 32719-5268 

email [email protected] 

web page http://www.Barcode-Automation.com 

Doing It Better - Because We Care.

 

Barcode Automation inc. 

 

Summary of Contents for BA-440 DualBeam

Page 1: ...CODE READER revised 3 29 2012 800 528 9167 407 327 2177 FAX 407 327 6172 Post Office Box 195268 Winter Springs FL 32719 5268 email Cust Svc Barcode Automation com web page http www Barcode Automation...

Page 2: ...Automation Inc has made every effort to insure that the information in this manual is both accurate and adequate It is recommended in the interest of safety and efficiency that each section be read ca...

Page 3: ...ation of this equipment in a residence is likely to cause interference in which case the user at his own expense will be required to take whatever measures necessary to correct the interference CDRH C...

Page 4: ...us radiation or electrical voltages OPTICAL SAFETY Never stare directly into laser beam The laser diode is interlocked with the motor that turns the polygon mirror so that if the motor slows or stops...

Page 5: ...hould be inspected and cleaned at 6 month intervals These include Window glass both inside and outside 8 sided gold mirror wheel Polygon Small mirror below gold wheel Polygon Fisheye lens in the silve...

Page 6: ...STARE INTO BEAM 658nm LASER DIODE 1 0 MILLIWATT MAX OUTPUT CLASS II LASER PRODUCT CLASS II LASER PRODUCT THIS PRODUCT CONFORMS TO DHHS REGULATION 21 CFR SUBCHAPTER J NOT USER SERVICEABLE Front AVOID E...

Page 7: ...n and Setup Steps 10 Determine where the Reader will be installed 10 What Wiring do I need 12 Typical Installation Illustration 15 Wiring Connections 16 Wiring Connection Definitions 17 Wiring Connect...

Page 8: ...s from Accu Sort Amtel ISI LazerData Communication RS232 Data Rate 2400 4800 9600 19200 38400 Baud Parameters 8N1 7E1 Communication Wiegand 26bit format Timing of Wiegand pulses is adjustable Indicato...

Page 9: ...4 from enclosure and extends out to 72 The laser lines are vertical with a fan shaped read area Read area chart is measured in inches above pavement This assumes that the center of the BA 440 DualBeam...

Page 10: ...DualBeam was not set up for your specific installation at the Factory you may have to configure the Reader after it is mounted in place To do this refer to the Operation and Configuration Manual for d...

Page 11: ...r should be mounted close to the edge of the road or drive without being in danger of collision with a vehicle It has a 6 foot reading distance which will extend out across the road or drive Traffic s...

Page 12: ...t closes to open the gate If access is denied the gate does not open and the Aux Out relay contact will close that can be connected to an indicator or alarm to indicate that access is denied Wiring Ne...

Page 13: ...h checks the database for valid numbers If access is granted the panel opens the gate Wiring Needed Shielded 3 conductor 18 AWG from reader to access control panel for Wiegand communication 2 conducto...

Page 14: ...requirements Communications For RS232 interface Three wires Transmit Receive Ground Minimum 3 conductor shielded cable 18 AWG For Wiegand interface Three wires Wiegand 0 Wiegand 1 Ground Minimum 3 co...

Page 15: ...1999 2012 Barcode Automation inc 15 Typical Installation Illustration With a 38 mounting post and a 6 curb the BA 440 DualBeam at 24 from the housing can read barcode decals between 35 and 65 above th...

Page 16: ...Copyright 1999 2012 Barcode Automation inc 16 Wiring Connections Wiring Terminal Block Main Power Switch Beeper On Off Switch...

Page 17: ...0 data communication to access system Comm signal ground or common to access system All three connections required for reliable communication Optional Vehicle Detect input to reader Not Required Aux I...

Page 18: ...s GND IN 24V IN The power input terminals for 24Vdc input are marked for the Ground and 24Vdc leads Reader is Reverse polarity protected NOTE The 24Vdc input must supply 1 5 Amps to the Reader for pro...

Page 19: ...ure to connect Wiegand communications to the access panel as shown on page 20 before proceeding with the following test To check compatibility with Optoisolated communications connect the access panel...

Page 20: ...Data1 terminals and Comm does not have a direct connection to the reader ground Voltage and ground reference is supplied by the access panel or telephone entry system Use 18Ga shielded copper cable fo...

Page 21: ...s panel or telephone entry not providing voltage on the Data0 and Data1 lines To change the Wiegand connection from optoisolated to direct 1 Move switch S1 to upper position away from the ISO label 2...

Page 22: ...In connection will allow decal reads only when the connection is Closed DO NOT APPLY VOLTAGE TO THESE TERMINALS THE TERMINALS SHOULD BE CONNECTED TO SWITCH OR RELAY CONTACTS ONLY Use 18Ga copper cabl...

Page 23: ...tion See the Configuration manual for details GdRead GdRead This is a dry contact relay output intended to control a gate operator See the Configuration manual for details Relay Contact Ratings Relay...

Page 24: ...roximately 6 months before becoming saturated Note Put the desiccant in the reader AFTER the installation is complete and you are ready to close up the enclosure Each time you open the Reader for serv...

Page 25: ...tion if necessary For more information on how to communicate with the reader refer to the Operation and Configuration Manual When the BA 440 DualBeam is powered on A short beep is heard The Main Power...

Page 26: ...ill light when data is flowing from receiver board Diag Green will light when decoder is in programming mode Heat Red will light when heater is turned on Sync Green will light when gold wheel is spinn...

Page 27: ...the Wiegand data lines When the barcode is read both should flash or flicker red very quickly These flashes indicate that the BA 440 DualBeam has sent out the Wiegand communication pulses for the bar...

Page 28: ...ly through the glass 3 Orient decal with the stripes running horizontal as shown 4 The bottom of the decal should be at least 36 inches above the ground 5 The top of the decal should be no more than 6...

Page 29: ...l decal back 1 inch from backing 90 3 Line up decal vertically on window 4 Place squeegee at top of decal Press firmly on top where the backing Press it firmly against window was peeled back and run i...

Reviews: