background image

User’s Guide

be mine 

Dual Electric Breast Pump

baby express

making parenting a breeze

baby express

Please read this user’s guide carefully before using

Summary of Contents for be mine

Page 1: ...User s Guide be mine Dual Electric Breast Pump baby express making parenting a breeze baby express Please read this user s guide carefully before using ...

Page 2: ...ode The nasal suction mode can help suck out baby s thick mucus relieve or eliminate baby s nasal discomfort Frequency Adjustment With three adjustable frequency high medium and low Mothers can adjust the suction rhythm according to their comfort Single Dual Mode Selection Conveniently touch to switch between single or double expression mode giving you the feasibility to have the option to express...

Page 3: ...lly or be unable to work Adjust the suction level to suit your comfort level Please disassemble all components of the product before sterilisation Do allow the product components to cool for about 20 minutes after the sterilisation is completed before assembling to avoid damage Please use the breast pump under the guidance of doctors nurses or certified personnel Do not over pump as it may cause i...

Page 4: ... when cleaning the valve and the silicone diaphragm If it gets damaged the breast pump will not be able to operate Lithium battery usage precautions Dismantling impacting extruding or throwing into the fire are prohibited Do not put it under direct sunlight or in a hot environment Please do not use when there is any bulging Do not disassemble batteries Some components of lithium batteries are flam...

Page 5: ...t before use If there is any missing part please contact the seller Silicone PP PP PP 2 2 2 PP PP Flange Cap No Material Food Grade Food Grade Food Grade Food Grade Food Grade Food Grade Food Grade Food Grade Food Grade Food Grade Remark Quantity 20 C 120 C 20 C 130 C 20 C 120 C 20 C 100 C 20 C 200 C 20 C 200 C 20 C 200 C 20 C 200 C 20 C 200 C 20 C 200 C Temperature Component Name Diaphragm Chargi...

Page 6: ...suction level for both sides is individually adjustable under the double suction function The default duration of expression mode is 28 minutes and for the bionic mode is 30 minutes Pause Button Touch the button to pause the breast pump second touch to resume working The unit will power off automatically after 3 minutes when left in pause mode Power Button Press and hold the power button to on the...

Page 7: ...ress the rim to ensure a perfect seal Product assembling sequence Insert the valve on the cylinder under the T joint flange push it in until it fits tightly Attach the bottle into the bottom of the T joint flange until it s tightly joined If using single expression mode insert one silicone tube into the left air vent hole at the bottom of the pump motor unit Put on the pump cover Please remove the...

Page 8: ...he suction gradually until you feel slight discomfort not a pain then slightly reduce the suction To end the session press the power button lightly to switch off the status light will automatically turn off Disassemble and clean all parts of the breast pump after use except for the motor adapter charging cable and silicone tube Nasal Aspiration Operations Press and hold button to change to Nasal S...

Page 9: ...r a professional institute for more information and advice Breast milk will expand after freezing do not fill the feeding bottle or milk bag to the brim with milk please reserve at least 1 4 space for expansion Please indicate the milk pumping date time on the milk bottle or milk bag To minimise nutrition loss please thaw the frozen milk in the refrigerator compartment or put the milk bottle bag u...

Reviews: