background image

 

Se

tt

in

gs

 1609

13_

 R

ev.

2

 

 

 

B

B

M

M

A

A

X

X

 

 

B

B

U

U

R

R

N

N

E

E

R

R

S

S

:

S

S

E

E

T

T

T

T

I

I

N

N

G

G

S

S

 

 
 

 
 
 
 

Summary of Contents for B-Home

Page 1: ...Settings 160913_ Rev 2 B BM MA AX X B BU UR RN NE ER RS S S SE ET TT TI IN NG GS S...

Page 2: ...Settings 160913_ Rev 2 TECHNICAL PARAMETERS...

Page 3: ...PERATURE CONTROL Hysteresis for water temperature regulation When setpoint is reached the burner restarts Normally 2 C range 0 9 If the water temperature is adjusted to 60 C when the temperature drops...

Page 4: ...r represents the maximum level of water temperature Normally 5 If the water temperature is adjusted to 60 C in case the temperature reaches 65 C the burner turns off it will start again when it reache...

Page 5: ...Settings 160913_ Rev 2 IGNITION ATTEMPS How many times the burner try to make the ignition before giving error Normally 1...

Page 6: ...Settings 160913_ Rev 2 LAMP TIME Time that the LCD display remains illuminated backlight after any button is not pressed Normally 5 min...

Page 7: ...Settings 160913_ Rev 2 ENABLE SECOND TANK NORMALLY OFF to enable this parameter if a second tank is used...

Page 8: ...Settings 160913_ Rev 2 SWITCH ON EXTERNAL THERMOSTAT NORMALLY OFF enables external thermostat ON Enabled OFF Disenabled...

Page 9: ...Settings 160913_ Rev 2 DISPLAY WATER TEMPERATURE This enables the visualization and water temperature management in the main display ON Enabled OFF Disenabled...

Page 10: ...Settings 160913_ Rev 2 GENERAL PARAMETERS...

Page 11: ...Settings 160913_ Rev 2 MAXIMUM IGNITION TIME If within this time limit the ignition is not made the burner stops and give error Normally 20 minutes...

Page 12: ...Settings 160913_ Rev 2 FLAME STABILIZING TIME After lighting the flame flame stabilization time wait before declaring burner on...

Page 13: ...tween cleanings When the time has elapsed the burner makes the fan working at maximum power for a duration indicated on next parameter grill cleaning time in order to clean the combustion grill Normal...

Page 14: ...Settings 160913_ Rev 2 GRILL CLEANING TIME Duration of the cleaning process where the fan is working at maximum power Normally 30 sec...

Page 15: ...Settings 160913_ Rev 2 ALARM DELAY Time delay in the activation of any alarm Ex If the temperature sensor is disconnected it doesn t give the alarm immediately only after this time Normally 120 sec...

Page 16: ...MUM START UP Value that the optical sensor has to reach in order to considerate the ignition done Not immediate it should never go under the value assigned for a duration indicated on the parameter TI...

Page 17: ...gs 160913_ Rev 2 LUX TURNING OFF If this level is not mainteined during the time settled on TIM LUX Neutral Zone the burner stops The display gives error if this happen during the functioning Normally...

Page 18: ...Settings 160913_ Rev 2 PRE IGNITION TIME RESISTANCE Time assigned to the resistance in order to ignite the fuel and activate the burner Normally 04...

Page 19: ...has to be activated If it s 00 the burner remain in modulation modality without stopping power 1 When it s between 1 and 99 indicates the waiting time minutes before stop When it finishes to turn off...

Page 20: ...ev 2 TIM DEAD BAND LUX It represents the time in which the optical sensor has to detect continuously above the value Minimum LUX start up Each time the detection value goes down restarts the count Nor...

Page 21: ...NG OFF TIME Time during which the fan is working at maximum power when the burner is turned off in order to burn completely the residues remained on the grill This cycle is activated before turn off t...

Page 22: ...Time during which the fan is working at maximum power when the burner is turned off as the result of an alarm in order to burn completely the residues remained on the grill This cycle is activated wh...

Page 23: ...Settings 160913_ Rev 2 TIM FUEL PRELOADING This parameter regulates the time seconds of the first loading of pellets...

Page 24: ...Settings 160913_ Rev 2 INITIAL VENTILATION Power of ventilation during the first phase of ignition...

Page 25: ...Settings 160913_ Rev 2 TIME FEEDER SCREW MAX Time between a load of pellet and the other...

Page 26: ...Settings 160913_ Rev 2 FEEDER SCREW LOADING TIME Charging time between the preload and flame stabilization...

Page 27: ...Settings 160913_ Rev 2 FEEDER SCREW ON START Charging time during stabilization flame...

Page 28: ...2 FEEDER SCREW CLEANING TIME In case time of pellet loading coincides with time in which the fan is doing the cleaning at maximum power just in this case the auger makes a loading for the time indicat...

Page 29: ...0913_ Rev 2 TIM FEEDER SCREW POWER 1 5 It represents the time of loading made by the system for each power from 1 to 5 There is a loading time for each power and it depends on the power desired and th...

Page 30: ...Settings 160913_ Rev 2 FAN SPEED ON LOADING It represents the power of the fan in percentage on charge phase...

Page 31: ...Settings 160913_ Rev 2 FAN SPEED ON STARTING It represents the power of the fan in percentage during flame stabilization...

Page 32: ...Settings 160913_ Rev 2 FAN SPEED ON CLEANING It represents the power of the fan in percentage during the cleaning phase Normally 99...

Page 33: ...Settings 160913_ Rev 2 FAN SPEED IN POWER 1 5 Fan speed at each power Depends on the fuel quantity and type and chimney draft...

Page 34: ...Settings 160913_ Rev 2 MECHANICAL CLEANING INTERVAL MIN Time between mechanical cleanings...

Page 35: ...e settled 1 sec 1 cm 2 sec 2cm etc It is not related to parameter mechanical cleaning interval min this parameter activates the mechanical cleaning system after the feeder makes a load On low power is...

Page 36: ...Settings 160913_ Rev 2 FAN SPEED IN FEEDER SCREW Fan speed on the external auger...

Page 37: ...Settings 160913_ Rev 2 SETTING PROCESS...

Page 38: ...v 2 INITIAL TARING Remove the plastic tube from the burner head in order to weigh each loading with a balance Start auger manually by pressing the button Weigh the pellet collected It is very importan...

Page 39: ...Settings 160913_ Rev 2 ADJUSTMENT WORKSHEET...

Page 40: ...2 minutes and put the value on Weight in the box and automatically the values seconds of charge for each level of power will be calculated on the green columns On PCI there is in this case 28 which in...

Page 41: ...Settings 160913_ Rev 2...

Reviews: