background image

 

 

AZKOYEN Medios de Pago, S.A

TEL.: +34 948 709 709 

Avda. San Silvestre, s/n 

 

 

Fax: +34 948 709 709 

31350 Peralta (Navarra) Spain 

 

 

www.azkoyen.com

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Technical Information: 

   T3 

HOPPER 

 

 

 

Summary of Contents for t3 hopper

Page 1: ...AZKOYEN Medios de Pago S A TEL 34 948 709 709 Avda San Silvestre s n Fax 34 948 709 709 31350 Peralta Navarra Spain www azkoyen com Technical Information T3 HOPPER...

Page 2: ...ERISTICS 21 3 4 1 Control board T3 Cctalk 21 3 4 2 Control board T3 parallel 23 3 4 3 Detection of coin levels 24 3 4 4 Detection of exit of coins 24 3 4 5 Double count 25 3 4 6 Identification of coin...

Page 3: ...OR ON THE COIN EXIT 37 6 3 MECHANICAL CONFIGURATION OF THE CHANGE RETURN RANGE 38 6 4 ADJUSTING THE MAXIMUM AND MINIMUM LEVELS IN THE HOPPER 42 7 TOOLS 43 7 1 PROGRAMMING TOOLS 43 7 1 1 HEUS user appl...

Page 4: ...their characteristics and modes of working are covered in this technical manual We have worked closely with the manufacturers of equipment and the end users of these systems on the design of the T3 h...

Page 5: ...T3 hopper T3 parallel T3 Cctalk With respect to the capacity of the storage of coins there are two options T3 single bowl T3 x 2 double capacity storage The T3 hopper incorporates advanced coin detect...

Page 6: ...the position and the type of connector in the machine to determine if the T3 hopper connecter should be fitted at the front or back The position of the main connector on the T3 may be changed with a...

Page 7: ...per Special care should be taken with the connector to make the connections physically coincide 7 If the T3 is a ccTalk model it will be necessary to configure the address of the hopper within the sys...

Page 8: ...Conect to Vs 24V pin 9 Tabla 3 connections for hardware address setup ii Dispswitch configuration through the dipswitches located on the main board Figure 2 Details of the location of the circuit boa...

Page 9: ...y the Table 4 Tabla 4 coins combinations for double coin models 9 In parallel models configure the working mode by means of the dipswitches depending on the logic used positive negative or pulse mode...

Page 10: ...ut a visual inspection to determine that there is no interference with either the entry or exit of the coins 13 Switch on the mains power The hopper will be ready to work In the Parallel T3 hopper the...

Page 11: ...10 mm from any electrical part of the hopper and any metal parts Inclination It should not be over 3 inclination in any of its axes Range of temperatures Working 0 to 60 C Storage 20 to 60 C Humidity...

Page 12: ...wide range of coins within the Euro zone all the coins except the 1 cent Moreover there are two additional configurations that complete the total payout range one for coins of smaller diameters and an...

Page 13: ...rmation below indicates the average capacity of coins depending on the configuration of the hopper SINGLE BOWL DOUBLE BOWL example capacities for the 1 coin Table 6 Capacity of coins by configuration...

Page 14: ...reach the exterior in a stabilised way facilitating the transport of the coin towards the refund slot on the machine Figure 6 Location of the entry and exit of coins 3 2 6 Ergonomic for the user Extr...

Page 15: ...s Figure 9 Recommended transport methods Reloading coins To facilitate access to the hopper in the operation of manual reloading and also in the channelling of coins from the validator there is a maxi...

Page 16: ...able 7 Voltage of power supply T3 Cctalk T3 PARALLEL V power supply MOTOR POWER SUPPLY V nom 24 VDC V min 18 VDC V max 27 VDC Table 8 Voltage of power supply of the Motor T3 PARALLEL T3 Cctalk and PAR...

Page 17: ...x6 way This connection has as the advantage that the machine may be wired up with 2x6 way ribbon cable and therefore be connected directly to the base of the hopper without the need of solder 1 AZKOYE...

Page 18: ...x male 2x6 way connector size 2 54 Figure 12 Connectors Azkoyen 2 Cinch connector Figure 10 Cinch connectors Azkoyen connector in the base plate Connector recommended in the master Type Molex 2x6 fema...

Page 19: ...ly of the type of connector used Cinch or Azkoyen the number of pins and there functions are remain the same T3 Cctalk Table 10 Pin out T3 Cctalk PIN FUNCTION 1 0V GND 2 NC 3 NC 4 Val Address 1 LSB 5...

Page 20: ...PIN FUNCTION 1 Pwr Motor 0 volt 2 Power supply Logic 0 volt 3 uP Sensor Exit 4 IN1 5 Exit Security 6 Exit Sensor Full 7 Exit Sensor Empty 8 IN2 9 Pwr Motor 10 Pwr Logic 11 Exit Raw Sensor 12 IN3 Table...

Page 21: ...sensorisation 2 Connection motor 3 Connection motor encoder 4 Connection Cctalk 5 Connection level detectors of hopper 6 Connection Programming and tools 7 Dipswitches configuration of Cctalk addresse...

Page 22: ...peration there is the web technical of Azkoyen Medios of Pago S A with the application HeUs For reprogramming in the field you may use in combination with the application HeUs the portable tool TL20 T...

Page 23: ...ion of positions 1 5 and 6 in the section 3 3 1 Control board T3 Cctalk Parallel connection The connection between the main external connector of the T3 hopper and the circuit board Mode selection dip...

Page 24: ...cations of the status LEDs 3 4 3 Detection of coin levels The detection of the level of coins in the hopper is done with two pairs of optic sensors a photodiode and a phototransistor The T3 hopper all...

Page 25: ...able of identifying the value of the coin at a previous stage This system measures the physical and magnetic characteristics of each coin and then contrasts it with the data previously programmed 3 4...

Page 26: ...the extraction system The T3 receives the order from the master and carries out the payment communicating the execution of the order or of any error or incidence in the case of not achieving complete...

Page 27: ...ull level of the hopper is measured by means of the sensors optics situated in the hopper There are two levels detected minimum and maximum These two levels may be adjusted manually by placing the ful...

Page 28: ...st detecting it and informing the master With this information the master may activate the payment of an additional coin in the case that it is considered appropriate In the hopper configurations of t...

Page 29: ...29 07 2009 assigned to the position of the coin exit and counting sensors to make them inaccessible from the exterior The T3 is the most secure hopper in the market...

Page 30: ...ays initiates any communication with any of its slave devices and these respond according to the command and its present state For more details related to the use of devices in Cctalk consult the manu...

Page 31: ...ce of signals that correspond to orders and confirmation of actions status or errors The connection diagram between the different hoppers and the master corresponds to a configuration in a star shape...

Page 32: ...he voltage of 24V of the motor may be permanently connected The motor is controlled by means of a level logic on IN3 When IN1 and IN2 receive 0V Mode 1 is selected When the power supply is connected t...

Page 33: ...control board on the front part shown in figure 21 the T3 has 3 LEDs that indicate its present status Their functions and the information related to the signals that are emitted are described below Fi...

Page 34: ...it sensor The diode emitter is not detected Error 4 Error of measurement in the optic sensor the magnetic sensor has detected two coins that the optic sensor optic has not detected Error 5 Error of me...

Page 35: ...dismantled to carry out service operations In this sense there has been a grouping of modular internal components Once you have accessed the interior by removing the covers the main assembly remains...

Page 36: ...y detectors Remove the cover The extraction system is now accessible Paso 2 Disconnect all the cables that come from of the PCB Remove the mechanical extraction assembly For this operation you need Ph...

Page 37: ...ing As prevention we recommend the cleaning of this sensor every 500 000 coins paid out 1 The optic sensor optic is situated in the front upper part of the hopper and is accessible from the coin hoppe...

Page 38: ...es of 1 5 to 3 2 mm There are mechanical configurations for a range of small coins CONFIG INFO track 1 extraction base and stirrer that accommodates the diameters between 16 25 to 22 mm and a configur...

Page 39: ...39 07 2009 4 Release the two plastic clips that fix the coin concentrator and pull it out 2 3 4 5...

Page 40: ...40 07 2009 6 7 8 9...

Page 41: ...d 7 Unscrew the screw wich fixes the electronic board to the plastic assembly 8 Release the clips located on the sides 9 Pull apart the assembly as shown in the figure 10 Flip upside down to pull appa...

Page 42: ...optic sensor to remove them from their present position 3 Insert the pairs of optic sensors in the empty and full positions making sure they are horizontally level Press lightly the sensors to fit the...

Page 43: ...the programming tool enter the technical web of Azkoyen sat azkoyen com and search by product and family groups Once you have saved these files in the directory HEUS DATAFILES you may transfer these...

Page 44: ...on to control the parallel hopper 7 2 1 Cctalk Manager With this application you can manage communications in Cctalk protocol simulate the available Cctalk commands modify their parameters and read th...

Page 45: ...Below are details of the main devices 7 2 1 1 USB Interface Cctalk This interface is connected to the USB port of the PC and provides a Cctalk bus to the exterior This connection may be connected to a...

Page 46: ...te the echo of the bus so it receives the commands that it sends Figure 26 RS232 interface Cctalk It is necessary power the unit with a power supply of 12 or 24VDC depending on the voltage the element...

Page 47: ...47 07 2009 connection is with a ribbon cable 2x5 way The use of this interface does not require the installation of additional drivers because the application Cctalk Manager recognises the connection...

Page 48: ...sion EN 55011 1991 Continuous conduced emission EN 55011 1991 Radiated emission 2 Electromagnetic immunity EN 50082 2 1995 EN 61000 4 2 ESD ENV 50140 1993 and ENV 50204 1995 EM and RF radiated EN 6100...