background image

INSTALLATION GUIDE

EN

GL

IS

H

AXIS T8120 Midspan 15 W 1-port

Summary of Contents for T8120

Page 1: ...INSTALLATION GUIDE ENGLISH AXIS T8120 Midspan 15 W 1 port ...

Page 2: ...ng to the Class B limit of EN 55022 This product fulfills the requirements for immunity according to EN 55024 office and commercial environments Safety This product complies to EN IEC 60950 1 Safety of Information Technology Equipment Japan この装置は クラスB 情報技術装置です この 装置は 家庭環境で使用することを目 的としていますが この装置がラジオやテレビジョン受信機に近接して使 用されると 受信障害を引き起こすことがあります 取扱説明書に従って正しい取り扱いをして下さい Canada This Class B digital apparatus...

Page 3: ...remove the product The power cord must have regulatory agency approval for the spe cific country in which is used for example UL CSA VDE on The power cord must be a three conductor type two current car rying conductors one ground conductor terminated on one end by an IEC 60320 appliance coupler for connecting to the product and on the other end by a plug containing a ground earthing contact The po...

Page 4: ...d to SELV interfaces on other equipment The product should only be connected to the IP device with which it was bought Using the product with other IP devices can cause damage to the IP device Follow basic electricity safety measures whenever connecting the device to its power source Read the installation instructions before connecting the product to its power source A voltage mismatch can cause e...

Page 5: ...e Do not use a cross over cable between the PoE Midspan output port and the load device Mounting Note the following before mounting the PoE Midspan to a fixed location The PoE Midspan may be wall or bench mounted using the rear side holes Do not cover the PoE Midspan or block the airflow to the PoE with any foreign objects Keep the PoE Midspan away from excessive heat and humidity and keep it free...

Page 6: ...e remote Ethernet network switch Patch panel 3 Connect the Data Power Out jack output to the terminal Hardware Overview Indicators LED Indicated Behavior Yellow On Power is on power is active Green On A remote terminal is connected Green Blinking Overload state or short circuit CAT 5 Cable Port connectivity Data and Power out Data in indicator Output port Input port Terminal Ethernet ...

Page 7: ...F to 104 F 10 to 90 RH no condensation allowed Storage 20 C to 70 C 4 F to 158 F Input voltage 100 to 240V AC 50 60 Hz Input current 0 5 A maximal Available Output Power Maximum 16 8 W Nominal Output Voltage 48V DC Input Data In Ethernet 10 100Base T RJ45 female socket Output Data Power Out Ethernet 10 100Base T plus 48 VDC RJ45 female socket with DC voltage on wire pairs 4 5 and 7 8 ...

Page 8: ...re that the input Ethernet cable is connected to the Data In port 6 Verify that the device is connected to the Data Power port 7 Try to reconnect the same device into a different Midspan If it works there is probably a faulty port or RJ45 connection 8 Verify that there is no short over any of the twisted pair cables or over the RJ45 connectors The end device operates but there is no data link 1 Ve...

Page 9: ...egard to the material contained within this document including but not limited to the implied warranties of merchantability and fitness for a particular purpose Axis Communications AB shall not be liable nor responsible for incidental Support or consequential damages in connection with the furnishing performance or use of this material This product is only to be used for its intended purpose Notic...

Page 10: ...Installation Guide Ver 2 1 AXIS T8120 15W Midspan 1 port Printed October 2014 Axis Communications AB 2012 2014 Part No 60330 ...

Reviews: