Page 1: ...INSTALLATION GUIDE AXIS Q60 S Series AXIS Q6042 S PTZ Dome Network Camera AXIS Q6044 S PTZ Dome Network Camera AXIS Q6045 S PTZ Dome Network Camera ...

Page 2: ...re trademarks or registered trademarks of SD 3C LLC in the United States other countries or both Also miniSD microSD miniSDHC microSDHC microSDXC are all trademarks or registered trademarks of SD 3C LLC in the United States other countries or both Support Should you require any technical assistance please contact your Axis reseller If your questions cannot be answered immediately your reseller wil...

Page 3: ...spose of it according to local raws and regulations For information about your nearest designated collection point contact your local authority responsible for waste disposal In accordance with local legislation penalties may be applicable for incorrect disposal of this waste Europe This symbol means that the product shall not be disposed of together with household or commercial waste Directive 20...

Page 4: ......

Page 5: ...s a hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE NOTICE NOTICE Indicates a situation which if not avoided could result in damage to property Other Message Levels Important Indicates significant information which is essential for the product to function co...

Page 6: ...Use only spare parts provided by or recommended by Axis Do not attempt to repair the product by yourself Contact Axis support or your Axis reseller for service matters Transportation NOTICE NOTICE NOTICE Keep the protective packaging When transporting the Axis product the protective packaging shall be replaced in its original position When transporting the Axis product use the original packaging o...

Page 7: ...f possible keep the protective plastic on the dome cover until the installation is complete Do not clean a dome cover that looks clean to the eye and never polish the surface Excessive cleaning could damage the surface For general cleaning of the dome cover it is recommended to use a non abrasive solvent free neutral soap or detergent mixed with pure water and a soft clean cloth Rinse well with pu...

Page 8: ...8 ...

Page 9: ...rview See page 10 3 Study the specifications See page 16 4 Install the hardware See page 18 5 Access the product See page 29 Package Contents AXIS Q6042 S Q6044 S Q6045 S PTZ Dome Network Camera AXIS T8605 Media Converter Switch Multi connector cable IP66 7 m 23 ft DIN rail clip Installation and Management Software CD Printed materials Installation Guide this document Extra serial number label 2x ...

Page 10: ...ome cover AXIS T8008 PS12 Power Supply AXIS T8310 Video Surveillance Control Board AXIS T90A Illuminators Installation Display For information about available accessories see www axis com Hardware Overview 2 1 3 4 5 6 7 8 9 10 11 1 Mounting hole for sunshield 3x 2 Pressure relief valve 3 Multiconnector 4 Hook for safety wire 10 ...

Page 11: ...ounting hole 3x 8 Part number P N Serial number S N 9 SD card slot SDHC 10 Status LED indicator 11 Control button Dome Cover 1 3 4 2 5 6 1 Dome bracket screw T25 4x 2 Dome cover 3 Rubber gasket 4 Rubber gasket 5 Dome ring 6 Dome ring screw T20 4x 11 ...

Page 12: ...AXIS Q60 S Series Sunshield Sold Separately 1 1 Screw holes Media Converter Switch 1 2 3 4 5 6 7 8 10 9 11 12 13 1 Power connector DC input 12 ...

Page 13: ...during firmware upgrade Amber red Flashes amber red if network connection is unavailable or lost Red Flashes red for firmware upgrade failure Status Green Shows steady green for 10 seconds for normal operation after restart Media Converter Switch LED Indicators LED Color Indication Unlit DC power unconnected or current protection engaged power overload Power Green DC power connected Amber 10 Mbit ...

Page 14: ...tivate or leave floating unconnected to deactivate 0 to 30 V DC Max load 100 mA Configurable Input or Output 2 blue 7 yellow Digital output Internal connection to ground when activated floating unconnected when deactivated If used with an external relay a diode must be connected in parallel with the load for protection against voltage transients Max voltage 30 V DC RX 3 green white Ethernet receiv...

Page 15: ...for network connectivity Each RJ45 and SFP network connector port has its own dip switch The dip switches control how the port forwards data For more information see the User Manual Dip switch position Description of use Default middle B When connecting to the network directly or through a router or network switch Left A When connecting to a camera or a device that is not intended for viewing data...

Page 16: ...s Operating Conditions The Axis product is intended for outdoor use Product Classification Temperature Humidity AXIS Q6042 S AXIS Q6044 S AXIS Q6045 S IEC 60721 4 3 Class 3K3 IEC EN 60529 IP66 ISO 20653 IP6K9K 30 C to 50 C 22 F to 122 F 10 100 RH condensing Power Consumption NOTICE NOTICE NOTICE Use a Safety Extra Low Voltage SELV compliant limited power source LPS with either a rated output power...

Page 17: ...C 2 Power in from power supply sold separately Max load 7 A 12 0 13 2 V DC min 75 W Power connector DC output Two 2 pin terminal blocks for power output pin 4 is not used 2 1 4 3 Function Pin Notes Specifications 12 V DC 1 2 Power out to camera Max load 6 5 A 12 0 13 2 V DC min 70 W GND 3 Ground DC output N a 4 N a Network connector internal Two 2 pin Ethernet terminal blocks 17 ...

Page 18: ...nal connector internal 2 pin terminal block Install the Hardware NOTICE NOTICE NOTICE The product shall be connected using a shielded network cable STP or an optical fiber cable All cables connecting the product to the network shall be intended for their specific use Make sure that the network devices are installed in accordance with the manufacturer s instructions For information about regulatory...

Page 19: ...era unit 2 Place the sunshield on the camera unit 3 Secure the sunshield using the supplied screws Replace the Dome Cover Replacing the dome cover is only necessary if you want to use a smoked dome cover or if the dome cover is scratched or damaged Smoked dome covers and spare clear dome covers can be purchased from your Axis reseller 1 Loosen the dome ring screws and remove the dome cover 2 Remov...

Page 20: ... Remove the caps from the intake and outlet valve 3 Place the chuck on the intake valve and press down to fill the camera with nitrogen 4 When the pressure inside the camera housing reaches 0 5 bar 7 psi the outlet valve will open Place your hand over the outlet valve to verify that the gas is flowing out 5 Keep the gas flowing through the camera housing for one minute before removing the chuck fr...

Page 21: ...pecific use Make sure that the network devices are installed in accordance with the manufacturer s instructions For information about regulatory requirements see Regulatory Information on page 2 Important Axis can only guarantee full functionality with the supplied media converter switch No other devices are supported 1 Make sure the mains supply is switched off 2 Mount the power supply and the me...

Page 22: ...the leftover outer foil shield and twist the braided shield into a coil 7 Cut off about 7 8 mm 0 27 0 32 in of the Ethernet wire foil shields 8 Strip off about 4 5 mm 0 16 0 20 in of the power wire jackets 1 2 2 3 4 1 Multi connector cable jacket 2 Outer foil shield 3 Braided shield 4 Ethernet wire foil shield 2x 22 ...

Page 23: ...e orange white 6 Ethernet wire orange 7 Digital I O wire yellow 8 Ground wire black 9 Power wire red 10 Ethernet wire foil shield 2x 11 Outer foil shield 12 Braided shield coil 9 Connect the network and I O wires to the internal network and I O connectors Open the lid insert the wires and close 10 Connect the ground and power wires to the power connector DC output 23 ...

Page 24: ...t wire green 5 Ethernet wire orange white 6 Ethernet wire orange 7 Digital I O wire yellow 8 Ground wire black 9 Power wire red 10 Power connector DC output 11 Ethernet connector internal 12 Ethernet connector internal 13 I O connector internal 14 Ground clip 15 Braided shield coil 16 Outer foil shield 17 Ethernet wire shield 2x 18 Clamp 24 ...

Page 25: ... cable jacket is firmly secured by the clamp Make sure all surfaces and contacts are clean and free from scrap shield material 12 Connect the network cables to the external network connectors RJ45 SFP as required Note An SFP module not included has to be used when connecting an optical fiber cable 1 2 3 4 5 6 7 1 Power cable DC input 2 Power connector DC input 3 Network connector SFP external 2x 4...

Page 26: ...dia converter switch to position C Leave the dip switch in its default position position B when connecting the port directly to the network For more information see Media Converter Switch Connectors on page 14 and the User Manual Important If the system is not defined use the default dip switch setting position B 1 1 Dip switch 4x 17 Attach the cover to the media converter switch 18 Switch on the ...

Page 27: ...plied multi connector cable shall be used 1 Install the selected bracket sold separately according to the instructions supplied with the bracket If drilling is required make sure to use drill bits screws and plugs that are appropriate for the material See www axis com for information on available mounting accessories 2 Route the multi connector cable through the holes in the mounting bracket 3 Sec...

Page 28: ...onnect the multi connector cable to the connector on the camera Use the alignment indicators to find the correct position NOTICE NOTICE NOTICE Be careful not do damage the multi connector cable when connecting it 6 Align the guide hole in the camera with the guide pin in the flange and fasten the network camera to the mounting bracket with the screws 28 ...

Page 29: ...IP address set the password and access the video stream This information is also available from the support pages on www axis com techsup Reset to Factory Default Settings Important Reset to factory default should be used with caution A reset to factory default will reset all settings including the IP address to the factory default values Note The installation and management software tools are ava...

Page 30: ...dress is 192 168 0 90 5 Using the installation and management software tools assign an IP address set the password and access the video stream It is also possible to reset parameters to factory default via the web interface Go to Setup System Options Maintenance Further Information The User Manual is available at www axis com Visit www axis com techsup to check if there is updated firmware availab...

Page 31: ...31 ...

Page 32: ...Installation Guide Ver M1 9 AXIS Q60 S Series Date October 2013 Axis Communications AB 2013 Part No 52211 ...