background image

Getting Started

AutoCAD

®

 

Electrical 2005

22502-010000-5000A    May 11, 2004 

Summary of Contents for AUTOCAD ELECTRICAL 2005

Page 1: ...Getting Started AutoCAD Electrical 2005 22502 010000 5000A May 11 2004 ...

Page 2: ...reen onair online Plans Specs Plasma PolarSnap Productstream Real time Roto Render Queue Visual Bridge Visual Syllabus and Where Design Connects Autodesk Canada Inc Trademarks The following are registered trademarks of Autodesk Canada Inc in the USA and or Canada and or other countries discreet fire flame flint flint RT frost glass inferno MountStone riot river smoke sparks stone stream vapour wir...

Page 3: ...res 7 About Wires 8 Inserting Wires 8 Trimming Wires 10 Chapter 2 Schematic Components 11 About Schematic Symbols 12 Inserting Components 12 Inserting Parent Components 12 Scooting Components 15 Inserting Child Components 15 Aligning Components 18 Inserting Push Buttons 18 Inserting Pilot Lights 20 Inserting System Reset Buttons 21 Generating Component Reports 23 ...

Page 4: ...PLC Modules 38 Inserting PLC modules 38 Removing Ladder Rungs 43 Using Multiple Insert Component 44 Chapter 5 Wire Numbers 49 About Wire Numbers 50 Attaching Source Signal Arrows 50 Attaching Destination Signal Arrows 52 Inserting Wire Numbers 58 Deleting Wire Numbers 61 Chapter 6 Panel Layouts 63 About Panel Layouts 64 Inserting Panel Components 64 Modifying Attributes 77 Inserting Nameplate Foot...

Page 5: ...utoCAD allowing you to quickly build and manage an electrical controls drawing set This manual provides conceptual information to help get you started and exercises that introduce you to the capabilities of AutoCAD Electrical About AutoCAD Electrical Learning AutoCAD Electrical Using Help Selecting a Project ...

Page 6: ... the integrated Design Support System DSS to access the online documentation It is also recommended that you have a working knowledge of Microsoft Windows NT 4 0 Windows 2000 or Windows XP and a working knowledge of electrical design and schematic ladder wiring diagrams Using Help As you work you may need additional information on the task you are performing The AutoCAD Electrical Help system prov...

Page 7: ...To select an AutoCAD Electrical project 1 Click the Project New Existing tool Menu Projects Project Project New Existing 2 In the Project dialog box click the Pick Project button 3 In the Recent Projects dialog box click the Other Projects button 4 In the Select Project file select AEGS wdp from the AeData Proj Aegs directory and then click Open Add Existing Drawings Add existing drawings to the a...

Page 8: ...ick OK 4 In the ADD Drawings s to Current Project dialog box select drawings DEMO01 dwg to DEMO09 dwg and then click OK The Project aegs dialog box is displayed with the files listed in the Project Drawing List section 5 Click OK Project in the Project aegs dialog box 6 In the No Project Database File Found dialog box click OK You now have convenient access to the needed files when you start using...

Page 9: ...he drawing name you want to preview 5 When you have finished viewing the drawings click the Close button in the Drawing Preview dialog box After you open a drawing you can still quickly view drawings using the Next and Previous Project Drawing tool To view project drawings once a drawing is open 1 In the Project aegs dialog box double click demo04 dwg to open 2 Use the navigation tools Previous Pr...

Page 10: ...6 ...

Page 11: ...Two wire segments connect if the end of one wire segment touches or falls with a small trap distance of any part of the other wire segment This connection can be at the end of the other wire or anywhere along the length of the other wire AutoCAD Electrical considers a wire connected to a component if the wire end falls within a trap distance from the wire connection point attribute of a component ...

Page 12: ...s You can start or end a wire segment in empty space from an existing wire segment or from an existing component If you start from a component the wire segment snaps to the wire connection terminal closest to your pick point on that symbol If the wire segment ends at another wire segment a DOT block name wddot dwg is applied if appropriate If it ends at another component the segment connects to th...

Page 13: ... 2 Two horizontal wires are created Next create two vertical wires between the two horizontal wires 6 Click the Insert Wire tool Menu Wires Insert Wire 7 Respond to the prompts as follows Select component or branch for WIRE S show connections Select the top wire at line reference 403 1 Select component or branch for WIRE S show connections to V start Vertical H start Horizontal Select the lower wi...

Page 14: ... Wire 2 Respond to the prompts as follows Fence Zext Select wire to TRIM Specify the wire segment at line reference 404 between the two vertical wires 1 Wire segments are trimmed back to a connecting dot a component or completely if neither is encountered along the segment Any connection dots that are no longer needed are removed The trimmed wire resembles the following image This is the end of th...

Page 15: ...inserting components you can use AutoCAD Electrical tools to automatically break wires assign unique component tags cross reference related components and enter values for catalog information component descriptions and location codes About schematic components Inserting parent components Inserting child components Generating component reports ...

Page 16: ...act symbols When the parent coil symbol is inserted it is assigned a unique component tag When the child contact symbols are inserted the child is related to the parent and the parent tag is assigned to the child symbol Use the Insert Component dialog box to insert components into demo04 dwg Inserting Parent Components Start by inserting the parent component To insert a parent component 1 Click th...

Page 17: ...ACTS MISCELLANEOUS2 DESCRIPTION list select Catalog Number 700 P200A1 7 Click the Catalog Check button to display the BOM information associated with the selected part number 8 In the Bill Of Materials Check dialog box click the Close button 9 In the Parts catalog dialog box click OK 10 In the Insert Edit Component dialog box Description section specify Line 1 MASTER CONTROL Line 2 RELAY 11 In the...

Page 18: ... box select MCAB5 and then click OK 13 In the Insert Edit Component dialog box Pins section notice that the following pin values have been inserted based on the selected part Pins 1 K1 2 K2 Click OK Any values entered here are saved as attribute values on the symbol itself ...

Page 19: ...r changes to a box and you are prompted to Select component wire or wire number for SCOOT to Move the cursor to the right and click The component is now in its new location You can use the Scoot tool to grab a component or a wire number and slide it back and forth along a wire You can grab a wire or a whole rung of circuitry and scoot it to a new position while keeping everything connected Inserti...

Page 20: ... 3 In the JIC Relays and Contacts dialog box click the Relay N O Contact button 4 Respond to the prompts as follows Specify insertion point Position the cursor on the wire at line reference 404 near the hot wire and click 2 5 In the Insert Edit Child Component dialog box Component Tag section click the Drawing button 6 In the Current Drawing list for FAMILY CR dialog box select MCAB5 CR403 MASTER ...

Page 21: ...ox verify that the following options are specified Component Tag Tag CR403 Description Line 1 MASTER CONTROL Line 2 RELAY Cross ref 403 Location code MCAB5 Pins Pin 1 A1X Pin 2 A1Y Click OK The child component is inserted If necessary use Edit Component to modify changes ...

Page 22: ...u Components Align 2 Respond to the prompts as follows Pick component to align with Horizontal Vertical Select the normally open limit switch component near the hot wire at line reference 406 1 A dashed line appears Select objects Select the previously inserted child contact component near the hot wire at line reference 404 2 3 Right click the selection The aligned component is placed Continue ins...

Page 23: ...ton 4 Respond to the prompts as follows Specify insertion point Position the push button on the wire at line reference 403 near the hot wire and click 3 5 In the Insert Edit Component dialog box verify the following value Component Tag PB403 In the Description section specify Line 1 EMERGENCY STOP In the Location code section click the Drawing button 6 In the All Locations Drawing dialog box selec...

Page 24: ...ox click the Pilot Lights button 3 In the JIC Pilot Lights dialog box click the Green Press to Test Button 4 Respond to the prompts as follows Specify insertion point Position the push button on the wire at line reference 404 near the neutral wire and click 4 5 In the Insert Edit Component dialog box verify the following value Component Tag LT404 In the Description section specify Line 1 CONVEYOR ...

Page 25: ...s the system reset button To insert a system reset button 1 Click the Insert Component tool Menu Components Insert Component 2 In the Insert Component JIC Schematic Symbols dialog box click the Push Buttons button 3 In the JIC Push Buttons dialog box click the Push Button N O 4 Respond to the prompts as follows Specify insertion point Position the push button on the middle of the wire at line refe...

Page 26: ...nent Tag PB403A In the Description section specify Line 1 SYSTEM Line 2 RESET In the Location code section click the Drawing button 6 In the All Locations Drawing dialog box select OPSTA3 and then click OK 7 Click OK on the Insert Edit Component dialog box Your finished schematic should resemble the following ...

Page 27: ...gurations that can be output to a report file exported to a spreadsheet or database program or inserted on to an AutoCAD drawing To generate a schematic component report 1 Click the Schematic Reports tool Menu Projects Reports Schematic Reports 2 In the Schematic Reports dialog box select Report Name Component Component Current drawing Verify that the following options have been specified Options ...

Page 28: ...ng Schematic Component report for all locations dialog box 4 Use this dialog box to incorporate this information into your drawing save it to a file or to print the report 5 In the Drawing Schematic Component report for all locations dialog box click the Close button This is the end of this tutorial chapter ...

Page 29: ...cal command to modify your drawing An invisible block WD_M is automatically inserted right on your drawing This block contains a number of attributes that define many AutoCAD Electrical settings Working with templates Inserting ladders Inserting 3 phase wiring Adding the current drawing to a project Adding drawing descriptions ...

Page 30: ...LECTRICAL dwt are supplied with AutoCAD Electrical You can create your own templates or use any drawing as a template When you use a drawing as a template the settings in that drawing are used in the new drawing Selecting Templates Use the AutoCAD Electrical template to start a new drawing To select a template 1 Select File New 2 In the Select template dialog box select ACAD_ELECTRICAL dwt and the...

Page 31: ...res Ladders Insert Ladder 2 In the Alert dialog box select Force this drawing s configuration setting to match the project settings option and then click OK Your existing drawing format automatically becomes compatible with AutoCAD Electrical upon insertion of an invisible block WD_M Various settings are stored as invisible attribute values on this block When you invoke an AutoCAD Electrical comma...

Page 32: ... Chapter 3 Drawings 3 In the Insert New Ladder dialog box specify Width 10 000 Spacing 1 0000 1st ref 1001 Length 20 000 Rungs 21 Phase 1 Phase NOTE Reference 1001 represents Page 10 Reference 01 Click OK ...

Page 33: ...g Ladders 29 4 Respond to the prompts as follows Specify start position of first rung Enter 1 5 21 press ENTER A single phase ladder is inserted in the drawing Use the same process to create three phase ladder ...

Page 34: ...Ladder dialog box specify Phase 3 Phase Spacing 0 5000 Spacing 7500 1st ref 1022 Index 1 Click OK 2 Respond to the prompts as follows Specify start position of first rung Enter 16 21 press ENTER Specify approximate position of last reference number Z zoom down R realtime pan Drag down to the bottom of the single phase ladder and click ...

Page 35: ...wing Inserting 3 Phase Wires You can insert vertical or horizontal 3 phase wiring Three phase wiring automatically breaks and reconnects to any underlying components that it finds in its path If it crosses any existing wiring wire crossing gaps automat ically insert ...

Page 36: ...se Bus dialog box verify the following default values are set Horizontal Spacing 0 7500 Vertical Spacing 0 5000 Starting at component or another bus Click OK 3 Respond to the prompts as follows Select component or bus for 3 phase wire Select the first vertical wire at line reference 1022 and drag across other wires Select component or bus for 3 phase wire to Click to place the 3 phase wire ...

Page 37: ...Projects 33 The three phase bus is inserted into the drawing Adding Drawings to Projects You can add new drawings to your project at any time Before you add a new drawing to a project it must be saved Select vertical wire ...

Page 38: ... Enter DEMO10 dwg Click Save To add the current drawing to a project 1 Click the Project New Existing tool Menu Projects Project Project New Existing 2 In the Project Aegs dialog box click the Add Current button 3 In the Add drawing s dialog box click the One button 4 In the Add Drawing to Project dialog box select DEMO10 dwg and then click the Open button The drawing is added to your project ...

Page 39: ...g and then click the Properties button 2 In the Properties Section Sub section Codes and Drawing Description dialog box Optional description for this drawing section specify Conveyor Line Click OK The description is now added to your drawing 3 In the Project Aegs dialog box Project Drawing List section select the Description button to view the drawing descriptions This is the end of this tutorial ...

Page 40: ...36 ...

Page 41: ...e menu From a small set of library symbols hundreds of PLC modules can be built on request This method allows the module to conform to the underlying ladder rung spacing so you can add spacers and break the module at insertion time About PLC modules Inserting PLC modules Removing ladder rungs Using Fence Insert ...

Page 42: ...into two or more pieces at insertion time Inserting PLC modules AutoCAD Electrical builds a PLC I O module as it is inserted A PLC module is selected the location is picked and the module is constructed using a small set of library symbols To insert a PLC module 1 Open DEMO10 dwg if it is not the current drawing 2 Click the Insert PLC Parametric tool Menu Components Insert PLC Modules Insert PLC P...

Page 43: ...Inserting PLC modules 39 Click OK ...

Page 44: ... module insert point Z zoom down R realtime pan Specify first wire closer to neutral wire ensure the X is directly on the horizontal wire 1 click 5 In the Module Layout dialog box verify the following defaults are set Spacing 1 0000 I O Points Insert all Click OK 1 ...

Page 45: ...lues and then click OK Rack Number 1 Slot Number 1 7 In the I O Address dialog box specify the beginning address Beginning address I 11 00 NOTE You can also select the beginning address from the Quick picks list Click OK 8 In the I O Addressing dialog box click the Decimal button ...

Page 46: ...42 Chapter 4 PLC The PLC module is inserted into your drawing ...

Page 47: ...rim Wire 2 Respond to the prompts as follows Fence Zext Select wire to TRIM Enter F press ENTER First fence point Select above the ladder rung at line reference 1018 1 First fence point to Drag through the last ladder rung at line reference 1021 2 click First fence point to to Right click the end the trim command The ladder rungs are removed from your drawing 1 2 ...

Page 48: ...ert Component JIC Schematic Symbols dialog box click the Limit Switches button 3 In the JIC Limit Switches dialog box select Limit Switch N O 4 Respond to the prompts as follows Component Fence From Point Select above the wire at line reference 1001 1 Component Fence From Point to Drag below the wire at line reference 1003 click the point 2 right click to end command 5 In the Keep dialog box selec...

Page 49: ...og after each and then click OK 8 In the Insert Edit Component dialog box verify the following values Component Tag LS1002 Location code MACHINE In the Description section specify Line 1 PALLET INSIDE Line 2 STATION Click OK 9 In the Keep dialog box select Keep this one Show edit dialog after each and then click OK 10 In the Insert Edit Component dialog box verify the following values Component Ta...

Page 50: ...on 3 In the JIC Terminals and Connectors dialog box click the Round with Terminal Number button 4 Respond to the prompts as follows Component Fence From Point Select above wire at line reference 1001 1 Component Fence From Point to Select below wire at line reference 1016 2 left click to end command and then right click to add terminal 5 In the Keep dialog box select Keep this one Show edit dialog...

Page 51: ...sert Component 47 6 In the Terminals dialog box specify Tag ID TS1 Terminal Number 1 Location code MCAB Click OK 7 In the Keep dialog box select Keep all don t ask unselect Show edit dialog after each and then click OK ...

Page 52: ...48 Chapter 4 PLC The terminals are automatically added to your drawing This is the end of this tutorial chapter ...

Page 53: ...ned to any and all existing wires on an individual selection an entire drawing selected drawings in a project or an entire project About wire numbers Attaching source signal arrows Attaching destination signal arrows Inserting wire numbers Deleting wire numbers ...

Page 54: ...he network to jump and continue to another network on the current drawing or on one or more project drawings To attach a source signal arrow 1 Click the Project New Existing tool Menu Projects Project Project New Existing 2 Double click demo03 dwg to open drawing 3 In the Drawing Modification dialog box click the Save Changes button to save the changes to the current drawing 4 Click the drop down ...

Page 55: ... Respond to the prompts as follows Select wire end for Source Select the end of the hot wire on the schematic on the right side of the drawing at line reference 332 1 6 In the Signal Source Code dialog box specify Code 24 VDC Click OK 1 ...

Page 56: ...s attached to the drawing you can then attach a destination signal to a wire segment of a wire network This enables the wire number assigned to another source wire network to automatically carry over to the current network To attach a destination signal 1 Click the drop down arrow on the Source Destination Signals tool to access the Destination Signal Arrow tool Menu Wires Signal References Destin...

Page 57: ... Destination Code dialog box click the Project button 4 In the Signal codes Project wide SOURCE dialog box select the following Click OK 5 In the Insert Destination Code dialog box verify the following value Code 24 VDC 6 Click the OK Update Source button ...

Page 58: ...ignals to the neutral wires 1 Click the Previous Project Drawing button to return to demo03 dwg 2 Click the drop down arrow on the Source Destination Signals tool to access the Source Signal Arrow tool Menu Wires Signal References Source Signal Arrow 3 Respond to the prompts as follows Select wire end for Source Select the bottom of the neutral wire at line reference 332 3 3 ...

Page 59: ...e next drawing Click OK to insert the signal arrows on the current drawing 6 Click the Next Project Drawing tool to access demo04 dwg 7 Click the drop down arrow on the Source Destination Signals tool to access the Destination Signal Arrow tool Menu Wires Signal References Destination Signal Arrow 8 Respond to the prompt as follows Select wire end for Destination Select the top of the neutral wire...

Page 60: ...56 Chapter 5 Wire Numbers 9 In the Insert Destination Code dialog box click the Project button 10 In the Signal codes Project wide SOURCE dialog box select the following option Click OK ...

Page 61: ... Insert Destination Code dialog box verify the following value Code 24 VDC NEUTRAL 12 Click the OK Update Source button Notice the cross references for your signal are inserted into the drawing above the neutral wire Now you can view the new signals ...

Page 62: ...trate the flow of the signals on your drawings Inserting Wire Numbers You can process and tag wires with sequential wire numbers or with wire numbers based upon the line reference location of the wire network When wire numbers are automatically inserted into a drawing the numbers will not be duplicated if they are defined on another network AutoCAD Electrical works from left to right top to bottom...

Page 63: ...4 Wire Tagging dialog box click the Pick Individual Wires button 5 Respond to the prompts as follows Select objects Select the wire segment between the two push buttons on line reference 403 1 right click The wire number is placed To add wire numbers to the entire drawing 1 Click the Automatic Wire Numbers tool Menu Wires Automatic Wire Numbers 2 In the Sheet 4 Wire Tagging dialog box click the Dr...

Page 64: ... Numbers tool Menu Wires Automatic Wire Numbers 2 In the Sheet 4 Wire Tagging dialog box click the Project wide button 3 In the Wire tagging Project wide dialog box verify the following settings Wire tag mode Reference based tags To do Tag retag all Freshen database for Signals Click OK ...

Page 65: ...og box click the No backup button 7 Click OK in the QSAVE dialog box Wire numbers are processed for the selected drawings Deleting Wire Numbers You can use the Delete Wire Numbers tool to select a wire number or to pick on any wire of the network To delete a wire number 1 Click the Delete Wire Number tool Menu Wires Delete Wire Number 2 Respond the prompt as follows Select objects Enter all press ...

Page 66: ...62 ...

Page 67: ...ate intelligent panel layout drawings Layouts can be driven from information carried on the AutoCAD Electrical schematic drawings or they can be constructed independently of the schematics About panel layouts Inserting panel components Modifying attributes Inserting footprints ...

Page 68: ... the footprint component directly into a panel layout Once placed the footprint remains linked to the original schematic components This allows for bidirectional updating between schematic components and the associated footprint blocks For this exercise use the Panel Layout tools You are now ready to select the components to insert on the panel layout To select schematic component footprints 1 Cli...

Page 69: ...matic Component List Panel Layout Insert dialog box verify the following settings and then click OK Extract component list for Project Location Codes to extract All Click OK 6 In the Schematic Components Panel Layout list select drawings to process dialog box select demo04 dwg 7 Click the Process v button verify demo04 dwg appears in the Drawing to Process section of the dialog box and then click ...

Page 70: ...66 Chapter 6 Panel Layouts 8 In the Schematic Components current project dialog box click the Mark Existing button An x marks the components that have already been placed in the project ...

Page 71: ... current project dialog box Display section select the Hide Existing radio button to display the schematic component footprints to be inserted into the panel layout You are now ready to begin manually inserting schematic component footprints on the panel layout ...

Page 72: ...ents current project dialog box select PB403 OPSTA3 EMERGENCY STOP and then click the Manual button NOTE The Manual button is used when schematic component footprints do not have a manufacturer and catalog number defined Next you need to define a catalog assignment for an automatic footprint selection ...

Page 73: ...okup button NOTE Use Choice B to enter a graphic without selecting a catalog number 2 In the Parts Catalog dialog box select CATALOG CONTACTS DESCRIPTION 800T D6A 1NO 1NC PUSH BUTTON MUSHROOM NEMA 4 13 Click OK 3 In the Footprint dialog box Choice A section verify the following values Manufacturer AB Catalog 800T D6A Click OK ...

Page 74: ... to the prompts as follows Select Location for PB403 Select to the left of PB414A 1 Select Location for PB403 Ortho on select ROTATION Right click to place the push button 5 In the Panel Layout Component Insert Edit dialog box click OK 1 ...

Page 75: ... automatically carried over to the panel footprint representation Now you re ready to insert the system reset button on the panel layout To manually insert the system reset footprint 1 In the Schematics Components current project dialog box select PB403A OPSTA3 SYSTEM RESET and then click the Manual button 2 In the Footprint dialog box Choice A section click the Catalog lookup button ...

Page 76: ... NC BLACK PUSH BUTTON MOMENTARY NEMA 4 13 Click OK 4 In the Footprint dialog box Choice A section verify the following values Manufacturer AB Catalog 800T A2A Click OK 5 Respond to the prompts as follows Select Location for PB403A Select to the left of Conveyor Motor Start 2 Select Location for PB403A Ortho on select ROTATION Right click to place the push button ...

Page 77: ... box click OK NOTE The Panel Layout Component Insert Edit dialog box is displayed each time you insert a panel footprint Information from the schematic representation is automatically carried over to the panel footprint representation Now you re ready to insert conveyor on light 2 ...

Page 78: ...utton 2 In the Footprint dialog box Choice A section click the Catalog lookup button 3 In the Parts Catalog dialog box select MANUFACTURER AB TYPE 30 5mm VOLTAGE ALL CATALOG MISCELLANEOUS1 VOLTAGE DESCRIPTION 800H QRT24G PLASTIC LENS 24VAC VDC FULL VOLT GREEN PILOT NOTE To easily sort the Catalog list select the Show list sorted by catalog part number on the Parts catalog dialog box ...

Page 79: ...Inserting Panel Components 75 Click OK 4 In the Footprint dialog box Choice A section verify the following values Manufacturer AB Catalog 800H QRT24G Click OK ...

Page 80: ...ompts as follows Select Location for LT404 Select to the left of the conveyor running light 3 Select Location for LT404 Ortho on select ROTATION Right click to place the push button 6 In the Panel Layout Component Insert Edit dialog box click OK 3 ...

Page 81: ...he drop down arrow on the Scoot tool to access the Align tool Menu Components Align 2 Respond to the prompts as follows Select component to align with Horizontal Vertical Enter V press ENTER Select component to align with Horizontal Vertical Select the power on button on the top left of the layout 1 Select objects Select the three components that were just inserted 2 4 right click The components a...

Page 82: ... Select LT404 2 right click to align horizontally 3 Follow steps 1 and 2 to align the remaining footprints You can also move component attributes To move an attribute 1 Click the Move Show Attribute tool Menu Components Attributes Move Show Attribute 2 Respond to the prompts as follows Select attribute to Move or pick on block graphics for list W Window move Select LT404 1 Select object Right clic...

Page 83: ...enu 2 In the Insert Footprint Panel Layout Symbols dialog box click the Nameplates button 3 In the Panel Nameplates dialog box click the Nameplate Catalog Lookup button 4 In Nameplate dialog box Choice A section click the Catalog lookup button 5 In the Parts Catalog dialog box select MANUFACTURER AB TYPE 800T Automotive COLOR_AND_ ALL CATALOG MISCELLANEOUS1 MISCELLANEOUS2 COLOR_AND_ DESCRIPTION 80...

Page 84: ...te 8 In the Panel Layout Nameplate Insert Edit dialog box click OK to insert the nameplate To insert a half round nameplate 1 Click the Insert Footprint tool Menu Panel Layout Insert Footprint Icon Menu 2 In the Insert Footprint Panel Layout Symbols dialog box click the Nameplates button 3 In the Panel Nameplates dialog box click the Nameplate Catalog Lookup button 4 In the Nameplate dialog box Ch...

Page 85: ...MANUFACTURER AB TYPE 800T Half Round COLOR_AND_ ALL CATALOG MISCELLANEOUS1 MISCELLANEOUS2 COLOR_AND_ DESCRIPTION 800T X59E Gray Custom Text Name Plate Click OK 6 In the Footprint dialog box Choice A section verify the following values Manufacturer AB Catalog 800T X59E Click OK ...

Page 86: ...e prompts as follows Select objects Select PB403A 2 right click to place the nameplate 8 In the Panel Layout Nameplate Insert Edit dialog box click OK to insert the nameplate The nameplate is inserted This is the end of this tutorial chapter 2 ...

Page 87: ...ions drawing 22 Browse for Folder 4 Create New Project File 3 Current Drawing List for FAMILY CR 16 Drawing Extract for All Locations 24 Drawing Modification 64 I O Address 41 I O Addressing 41 I O Point 41 Insert New Ladder 28 30 Insert Edit Component 14 Insert Edit Contact 17 Keep 44 46 47 Module Layout 40 Panel Layout Component Insert Edit 70 Parts Catalog 13 PLC I O Module Selection Insert 38 ...

Page 88: ...for exercises 3 Q Qsave dialog box 24 R reports 23 S Schematic Component Report dialog box 23 schematic component reports 23 Schematic Components dialog box 66 schematic symbols green press to test pilot light 20 limit switch button 44 normally open limit switch 44 normally open push button 21 normally open relay 16 pilot lights 20 push buttons 19 21 relays button 12 16 standard coil 12 terms and ...

Reviews: