OUTDOOR LOW VOLTAGE SPOTLIGHT 

  

IP65

 

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION 

LEAVE A COPY FOR THE USER / MAINTENANCE ENGINEER FOR FUTURE REFERENCE 

USING THIS INSTRUCTION LEAFLET 

This instruction leaflet has been designed as a general installation guide to help you install your particular outdoor 
luminaire. Please pay particular attention to how your luminaire is wired. If you require any guidance or any further 
information regarding your outdoor luminaire, please contact us via the details below or visit our web site. 

IMPORTANT INSTALLATION INFORMATION 

 

Installation should be carried out in accordance with the latest edition of the I.E.E. Wiring Regulations (BS7671) and taking 

into consideration the latest Building Regulations. If in doubt, consult a qualified electrician. 

 

Before commencing any installation or maintenance work, ensure electricity is switched off at the mains. 

 

Please take note of the IP (Ingress Protection) rating of your luminaire when deciding location. 

 

All luminaries run HOT. It is the installer’s responsibility to consider fire & safety risks and take appropriate precautions. 

 

Please take note of the maximum lamp wattage for this luminaire is 20W. 

 

Ensure that ALL electrical connections are tight with no loose strands, including factory made connections. 

 

Please take note of the nearest illuminated surface as detailed on the product label. 

 

IMPORTANT USER INFORMATION 

 

Always switch off mains supply before installation, servicing, fitting or changing the lamp. 

 

Replace failed lamps immediately. Allow the lamp and fitting to cool before replacing lamp. Check that the correct lamp type 

and wattage is fitted. Dispose of failed lamps correctly. 

 

It is recommended to clean every two to three months to preserve the finish of this product. Do not use solvents or 

aggressive cleaning agents. 

 

GENERAL INSTALLATION - SAFETY 

When positioning your luminaire, please take note that outdoor electrical installations should be installed by qualified 
electricians. Proper circuit protection for all exterior electrical services should include a residual current device (RCD), also 
known as an earth leakage circuit breaker (ELCB). This simple device ensures that the power is cut off immediately; it 
detects a leakage of current to earth, which indicates an electrical fault which is potentially threatening to life. Observe these 
few simple rules and keep your outdoor electrical installation safe. 

 

GENERAL INSTALLATION – LAYING CABLE 

Laying electrical cables in the ground may be subject to specific regulations. The aim is to ensure that the cables are buried 
deeply enough in the ground to avoid any disturbance which is likely to occur. Where armoured cables can be buried at 
adequate depth to avoid being damaged by any reasonable foreseeable disturbance of the ground, they can be laid in a 
buffer layer of sand and covered with cable warning tape. Where it is not possible to bury the cables deeply enough because 
of the presence of tree roots or unsuitable ground conditions, extra mechanical protection around the cables will be 
required. This is usually in the form of plastic ducts or conduits through which the cables are run

 