background image

REVERSE OSMOSIS SYSTEM

Cebilon Platinum with pump 

Operating and maintenance instructions

Before installing and using the system, please read these instructions carefully. 

EN

Summary of Contents for Cebilon Platinum

Page 1: ...REVERSE OSMOSIS SYSTEM Cebilon Platinum with pump Operating and maintenance instructions Before installing and using the system please read these instructions carefully EN...

Page 2: ...rine Clean water Waste water 2 Water leakage system 1 Regulator 3 Low pressure switch 4 5 m sediment filter 5 Pressure pump 6 Activated carbon granulate filter 7 1 m sediment filter 8 4 way shut off v...

Page 3: ...he 1 m sediment filter removes the rest of the particles to ensure the correct functioning of the membrane The membrane is where the phenomenon of reverse osmosis occurs This component consists of a p...

Page 4: ...pump when the water supply is turned off or the pressure is less than 0 2 bar 3 psi The pressure pump increases the pressure on the water flowing through the 5 m sediment filter to the value required...

Page 5: ...le for the model with pressure pump Do not use water for this system that is microbiologically unsafe that has not been sufficiently disinfected before or after operation or that is of unknown quality...

Page 6: ...s the function of a pH regulator and then to the clean water tank To ensure reliable functioning and a long service life of the membrane the amount of waste water must always be bigger than the amount...

Page 7: ...ly system it must be subjected to a drinking water analysis by the responsible institutions 5 If the water used is not tap water make sure that the water is properly disinfected The ters are considere...

Page 8: ...e adapter by wrapping it with Teflon tape in a position that allows easy opening and closing of the ball valve Fig 5 a Then connect the water supply hose to the ball valve Fig 5 b Make sure that the b...

Page 9: ...s a risk that you will carry out the drilling incorrectly The tube should be carefully installed between the tap and the clean water outlet of the system Water connection fittings 1 Tap tube 2 Upper t...

Page 10: ...ect the adapter to the power supply Open the tap for the clean water Close the clean water tank valve By opening the 1 4 ball valve the tap water is supplied to the system Fig 8 The pump starts workin...

Page 11: ...house we recommend that you close the water inlet valve for safety reasons Fig 8 Repairs have to be carried out by qualified personnel The maintenance of your system should only be carried out by an...

Page 12: ...vice life depends on the quality of the inflowing water Activated carbon granulate filter GAC 6 12 months This filter removes the chlorine from the water Excess chlorine reduces the service life of th...

Page 13: ...r the dissolved solids TDS from the water To check the efficiency of the system check the water in the system regularly Please also replace the filters according to the specified replacement intervals...

Page 14: ...tact a technician The system generates excessive noise A water flow noise can be generated in the waste water tube Correctly align the clamp attached to the siphon and to the outlet pipe This may be d...

Page 15: ......

Page 16: ......

Reviews: