background image

 

 

English, French (et Canada) 
 

This instruction manual is for use by an authorized service technician 
to install an Atwood 

– 

hydro flame

™ furnace. Should you require 

further information, contact your dealer or Atwood Mobile Products 
LLC 
This furnace design is certified for installation in recreation vehicles as 
a MSP Category III furnace. Follow this installation instruction to insure 
safe operation of the furnace. Failure to install furnace according to this 
installation instruction nullifies the furnace warranty. 

 

 

 

 

 
 
 

 

  

Effective 8/15 

 WARNING

 

Installation of this appliance must be in accordance with the written 
instructions provided in this manual. No agent, representative or 
employee of Atwood or other person has the authority to change, 
modify or waive any provision of the instructions contained in this 
manual.

 

 

 

WARNING 

Avoid possible injury or death 

Improper  installation,  adjustment,  alteration,  service  or  maintenance 
can cause property damage, personal injury or loss of life. Refer to the 
installation  instructions  and/or  owner’s  manual  provided  with  this 
appliance. A qualified installer, service agency or the gas supplier must 
perform installation and service. 

 

 

 CRITICAL INSTALLATION WARNINGS 

 

DO NOT install furnace on material that restricts return air, like 
carpet or any soft material such as vinyl. 

 

DO NOT install furnace where clearance to combustibles cannot 
be maintained. 

 

DO NOT modify furnace or intake or exhaust vents in any way. 

 

DO NOT alter furnace for a positive grounding system. 

 

DO NOT hi pot furnace unless electronic ignition system (circuit 
board) has been disconnected. 

 

DO NOT use battery charger to supply power to DC model 
furnace even when testing. 

 

DO NOT use 120-volt AC current with DC models. 

 

DO NOT use furnace cabinet area as a storage compartment. 

 

DO NOT vent furnace with venting system serving another 
appliance. 

 

DO NOT vent furnace to an outside enclosed porch area. 

 

DO NOT use for temporary heating of buildings or structures 
under construction. 

 

Protect installation materials from degrading air and flue exhaust 
systems. 

 

Protect furnace electrical components from water. 

 

Compartments must be closed when in operation. 

 

Should the gas supply fail to shut off during operation or 
overheating occurs, shut the gas valve off to the furnace before 
shutting off electrical supply. 

 

DO NOT use this furnace if any part has been under water.  

 

DO NOT use petroleum or citrus type cleaner on plastic parts, as 
damage may occur. 

 
 
 
 

 
 
 
 
 
 
 

1120 North Main Street • Elkhart, IN 46514 

USA & Canada :

 1-866-869-3118 

Internet:

 http://www.atwoodmobile.com 

 

Literature number 31970 

hydro flame

™ 

AFS Series Furnaces Models 

AFSAD12 

AFSD12, AFSD16, AFSD20 

 

Technical Installation Manual

 

 

 FOR YOUR SAFETY 

Do not store or use gasoline or other flammable vapors and liquids in 

the vicinity of this or any other appliance.

 

 WARNING

 

Be sure the furnace and all ignition systems are “off” during any type of 
refueling and while vehicle is in motion or being towed.

 

TO THE INSTALLER:

 

  LEAVE THIS MANUAL 

WITH THE APPLIANCE. 

TO THE CONSUMER:

  

RETAIN THIS MANUAL FOR 

FUTURE REFERENCE.

 

SAFETY ALERT SYMBOLS 

Safety Symbols alerting you to potential personal safety 

hazards obey all safety messages following these 

symbols 

 

WARNING 

Avoid possible injury or 

death 

 

 

CAUTION 

Avoid possible injury 

and/or property damage 

 WARNING 

FIRE OR EXPLOSION

 

If  the  information  in  this  manual  is  not  followed 
exactly,  a  fire  or  explosion  may  result  causing 
property damage, personal injury or loss of life. 

FOR YOUR SAFETY 

WHAT TO DO IF YOU SMELL GAS: 

 

Extinguish any open flame. 

 

Evacuate all persons from the vehicle. 

 

Shut off the gas supply at the gas container 
or source. 

 

Do not touch any electrical switch, or use 
any phone or radio in the vehicle. 

 

Do not start the vehicle’s engine or electric 
generator. 

 

Contact the nearest gas supplier or qualified 
service technician for repairs. 

 

If you cannot reach a gas supplier or 
qualified service technician, contact the 
nearest fire department. 

 

Do not turn on the gas supply until the gas 
leak(s) has been repaired. 

A qualified Service Technician 

Service Center or gas supplier must perform 

installation and service. 

 

Summary of Contents for AFSAD12

Page 1: ...uctures under construction Protect installation materials from degrading air and flue exhaust systems Protect furnace electrical components from water Compartments must be closed when in operation Sho...

Page 2: ...abinet Size Voltage Input Btu hr Gas Type Style Valve Model Rev S small SA small low amp D 12 VDC 12K 16K 18K 1 LP 1 Door 2 LD small vent 3 door w rear gas fitting 4 door w pigtail 5 door w pigtail re...

Page 3: ...ing is given based on the installed position of the furnace Clearances Top Sides Rear Bottom to screw heads Blower side cabinet opening Vertical or Horizontal 1 2 1 2 1 2 0 16 sq in Spacing of 1 4 to...

Page 4: ...s made at each register the total reading should not be less than what is shown in the table below for each BTU size If readings are below the table values airflow can be improved by adding ducts or b...

Page 5: ...ap of the vent tube must be a minimum of 1 1 2 for proper function and exhausting of furnace 1 Locate were furnace will be installed and cut a hole opening as shown through the side wall where unit wi...

Page 6: ...gs are treated with a sealing compound resistant to the action of propane LP gas DO NOT put sealing compound on flare fittings 3 Remove grommet plug from furnace After inserting gas line through gas p...

Page 7: ...nace a burn off of excess oils remaining from manufacturing process may cause smoking or fumes for 5 10 minutes NOTE if furnace should lock out the blower will go off in 90 seconds and remain off unti...

Page 8: ...WIRING AND LADDER DIAGRAM...

Page 9: ...9...

Page 10: ...10...

Page 11: ...11...

Page 12: ...12 Figure 1 Large Paddle Kit 31093 Figure 2 Small Paddle Kit 31094 Figure 3 Valve Kit 31098 Figure 4 Valve Kit 31096 Figure 5 Valve Kit 31097 Figure 6 Electrode Adjustment...

Page 13: ...VERTISSEMENT Installation de cet appareil doit tre faite selon les instructions crites fournies dans ce manuel Aucun agent de repr sentant ou d employ Atwood ou toute autre personne n a le pouvoir de...

Page 14: ...UES 19 BLOC D ALIMENTATION 19 DIMENSIONNEMENT DE CHEF D ORCHESTRE 19 INSTALLATION DE THERMOSTAT 19 MODE D EMPLOI 19 Fermer Unit 20 MOD LE DE NOMENCLATURE AF S D 20 1 1 1 A Four Atwood Taille de coffre...

Page 15: ...les hauteurs libres indiqu es et doivent b n ficier de la pleine longueur et la largeur de l unit Espacement est donn bas sur la position de montage du four D gagements Retour au d but mm C t s mm Arr...

Page 16: ...une l vation de temp rature tel que sp cifi sur la plaque signal tique Apr s que l installation du four et conduit du syst me est termin e pour obtenir une l vation de temp rature devrait ajust e Le...

Page 17: ...rs De ventilation doivent maintenir chevauchements de 63 5mm po sur chappement tube et 12 7mm sur le tube d air NE d passez pas l paisseur maximale 6 Four s curis l tage avec pattes et vis vis de type...

Page 18: ...la connexion du trou 5 4 standard conduit et registre rond standard Voir requis des conduits de section pour exigences Air de d charge de la persienne grill rond peut tre adress e 360 en tournant la p...

Page 19: ...5 10 40 50 8 55 70 6 75 100 4 95 120 2 130 150 1 150 1 0 170 2 0 195 3 0 225 4 0 260 Ce radiateur est con u pour la masse n gative de 12 volts seulement N essayez pas de changer de four pour un syst m...

Page 20: ...glage d sir Si la valeur au dessus de la temp rature ambiante ventilateur viendra 6 Permettre 30 secondes pour br leur principal s allume apr s que le souffleur s allume Ce four est quip d un disposi...

Reviews: