background image

Gas Countertop Hot Plates/Cooktops

Operating Instructions

Before you begin, please read these instructions carefully to

use this product correctly, to make the product perform ideally, and

to avoid hazards.

Models: ATHP-12-2/ ATHP-24-4 / ATHP-36-6

Summary of Contents for ATHP-12-2

Page 1: ...Plates Cooktops Operating Instructions Before you begin please read these instructions carefully to use this product correctly to make the product perform ideally and to avoid hazards Models ATHP 12 2 ATHP 24 4 ATHP 36 6 ...

Page 2: ...manual in a safe place for convenient reference and operation This instruction manual is subject to any change without further notice and the manufacturer reserves the right of final interpretation The appliance is designed for commercial purposes not for household use A statement instructing the purchaser to post in a prominent location instructions to be followed in the event the user smells gas...

Page 3: ...n 3 2 Brief Introduction 3 3 Manufacturer s Authority and Responsibility 3 4 Parameter Specifications 4 5 Transport and Storage 6 6 Installation and Debugging 6 7 Safety Notices and Precautions 8 8 Operating Instructions 9 9 Cleaning and Maintenance 11 10 Troubleshooting 12 11 Spare Parts 13 12 Accessories List 18 ...

Page 4: ... lack the necessary knowledge or experience unless with appropriate instructions and sufficient safety 2 Brief Instruction The product is a series of gas char broilers in our company production which is novel designed reasonable structured convenient operated durable used and convenient maintained It s equipped with a cast iron burner and a high efficiency stainless steel tubular burner and a pilo...

Page 5: ...cians Use the spare parts or accessories provided by non manufacturers Accidents caused by force majeure Not strictly comply with related guide of this instruction by any reason 4 Parameter Specifications 4 1 Outline Dimensions in ATHP 12 2 ATHP 24 4 ...

Page 6: ...1 Model of burners and control method Gas Species Intake tube pressure in W C Per BTU B T U h Total BTU B T U h Nozzle No ATHP 12 2 2 pieces Independent control Natural Gas 4 25 000 50 000 43 L P Gas 10 25 000 50 000 53 ATHP 24 4 4 pieces Independent control Natural Gas 4 25 000 100 000 43 L P Gas 10 25 000 100 000 53 ATHP 36 6 6 pieces Independent control Natural Gas 4 25 000 150 000 43 L P Gas 1...

Page 7: ...t be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2psi 3 45kPa 6 1 Unpacking and Installation Please dispose of all packaging materials and residues after unpacking Check the equipment If it is damaged please keep wrappers and receipts which must be signed by the carrier representative Driver and contact the carriers to ...

Page 8: ...ombustion and air circulation Leave enough distance in front of the equipment to take apart the control panel All major parts in addition to the burner remove from the front intake tube It may be necessary to adjust the balance of air input by authorized and licensed technicians Thread glue must be resistant to the action of liquefied petroleum gases Warning Use soap water or testing instrument to...

Page 9: ...tion When customers smell gas in the process of using should take safety precautions immediately Immediately turn off the main gas valve extinguish all heat and flames and call 911 Safety information can be obtained from your local gas suppliers When using this equipment safety precautions should always be followed including the following The hot plates cooktops burners cooking grates and outside ...

Page 10: ...t at the factory Each burner has a pilot light 8 1 Lighting the pilot light Turn the control valve at the position of 0 Fig 2 make sure all knobs are in the close state Light and hold an ignition source at the pilots The pilot light may not be lighted immediately for existing gas in the pipe Wait a minute the pilot light will be lighted after the gas extinguished Tips You can use a screwdriver to ...

Page 11: ...inated after the power up to the maximum for burning an hour 8 5 Exchange main fire nozzle to switch gas source Remove control panel cooking grates the pilot light head and burner remove main fire nozzle with proper open spanner exchange nozzle of another gas source then screw it Reinstall burner the pilot light head cooking grates and control panel in proper order Caution Each main fire orifice o...

Page 12: ...ow the lighting instructions to work again after cleaning Warning Wait for the equipment to cool down after the unit has been turned off before you clean Cut off the gas source when not in use If the equipment is not used for a long time clean the surface by wiping it with a soft cloth and place it in a well ventilated area Comprehensively check the equipment at least once every year by authorized...

Page 13: ...p residue Reinstall after cleaning Warning if the catch tray is permitted to fill too high should be cleaned Per use 10 Troubleshooting Table 3 Problems Possible causes Problem solving Not lighting 1 Insufficient gas pressure in pipe 1 Contact the local gas supply dept 2 Nozzle occlusion 2 Dredge nozzle Ignite the pilot light but not the main fire 1 Insufficient gas pressure in pipe 1 Contact the ...

Page 14: ...Not match nozzle aperture with gas resources 2 Adjust nozzle diameter 3 Not enough air to ignite 3 Increase damper opening degree 4 In the peak of using gas sources of gas float heavy 4 Turn down valves flow Turn it up after the peak The problems mentioned above are only for reference If any fault occurs please stop using and contact technicians to check and repair Safety first turn off the power ...

Page 15: ... 14 5 4 3 1 2 6 7 8 9 10 11 12 14 15 3 16 17 19 18 20 21 23 22 24 26 27 29 13 25 28 Fig 8 ...

Page 16: ... 12 2 ATHP 24 4 ATHP 36 6 4 301140001 Kirsite knob 2 ATHP 12 2 4 ATHP 24 4 6 ATHP 36 6 5 21103001013 Control panel 1 605 185 ATHP 12 2 21103002013 905 185 ATHP 24 4 21103003013 1205 185 ATHP 36 6 6 21205001002 21205002002 21205003002 surround 1 310 640 203 ATHP 12 2 610 640 203 ATHP 24 4 910 640 203 ATHP 36 6 7 301030002 A18 stopcock 2 A18 318 ATHP 12 2 4 ATHP 24 4 6 ATHP 36 6 8 301040004 30104000...

Page 17: ... ATHP 36 6 15 301060002 Needle type pressure joint screw arbor 1 M5 23 ATHP 12 2 ATHP 24 4 ATHP 36 6 16 301990001 Damper cover 2 ATHP 12 2 4 ATHP 24 4 6 ATHP 36 6 17 301081002 Stainless steel cross recess head screw 2 M4 8 ATHP 12 2 4 ATHP 24 4 6 ATHP 36 6 18 301010001 Short ejector 1 ATOSA 0001 ATHP 12 2 2 ATHP 24 4 3 ATHP 36 6 19 301081001 Stainless steel cross recess head screw 4 M5x16 ATHP 12 ...

Page 18: ...103001015 Burner back plate 1 607 76 71 ATHP 12 2 2 ATHP 24 4 3 ATHP 36 6 27 21203001001 Unit 1 310 700 37 ATHP 12 2 21203002001 610 700 37 ATHP 24 4 21203003001 910 700 37 ATHP 36 6 28 301030014 pressure maintaining valve 1 4 10 ATHP 12 2 ATHP 24 4 ATHP 36 6 29 301070007 Double burners countertop hot plates cooktops in take tube 1 ATHP 12 2 301070008 Four burners countertop hot plates cooktops in...

Page 19: ...ing valve connects with air intake must be installed by authorized and licensed technicians to ensure interface tightness 2 Screw the hex nut Fig 9 before connect air intake ensure gas mark Fig 10 on the plastic core whether match with connected gas source if not then pull out the plastic core and change another head insert it again The same as exchanging gas source 3 When exchange gas source use ...

Page 20: ... durability and low maintenance charge But to update some components and necessary maintenance can prolong life length of the products Contact the dealer for assistance In order to avoid confusion please follow the format in figure 8 and table 4 ...

Reviews: