manualshive.com logo in svg
background image

 

 

 

USER MANUAL 

 

Blazer Vista   

400/600/800VA 

 

 

 

 
 
 
 
 
 
 
 
 

Uninterruptible Power System 

 
 

 

Содержание Blazer victa 800 VA

Страница 1: ...USER MANUAL Blazer Vista 400 600 800VA Uninterruptible Power System ...

Страница 2: ...position and disconnect the power cord form the AC power supply to properly disable the UPS Do not allow any liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit This unit intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in loc...

Страница 3: ...arts on the top of batteries 5 Disconnect charging source prior to connecting or disconnecting batteries terminal Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing batteries replace with the same number of the sealed lead acid batteries This pluggable type A eq...

Страница 4: ...System Description Front Panel 1 LCD Back Light 2 Power ON OFF Switch Back Panel 1 Communication Port optional 2 Modem Phone LineSurg Protection 3 AC Output 4 AC Input ...

Страница 5: ...tall the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Do not operate your UPS in an environment where the ambient temperature or humidity is high On the other hand place the UPS unit away from monitor at least 20cm to avoid interference 3 Charging This unit is shipped from the factor...

Страница 6: ... Plug incoming internet line into the In socket at the back of the UPS Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the UPS Plug the other end to the modem input socket as shown 6 Serial Cable Connection To allow for unattended system shutdown for your operating system connect the serial cable as per diagram below ...

Страница 7: ...th ON The LED lighting 8 LCD Display Specification The LED will always turns on when UPS works including in off charging mode and fault mode When LCD start to work it will display all information for 3s 1 When in normal mode it will display as below 2 When in AVR mode it will display as below And the mark will flicker every 1second ...

Страница 8: ...V 40V input voltage will display 000 4 When in off charging mode it will display as below Note the output voltage always is displayed as 000 in off charging mode 5 When in fault mode it will display as below FAULT character and the reason of fault only Note the fault code will be showed in fault mode ...

Страница 9: ... 100 7 Battery capacity definition Battery LEVEL Battery bar Indication Battery voltage 11V 11V Battery voltage 11 5V 11 5V Battery voltage 12 5V Battery voltage 12 5V 8 When over load the mark will flicker every 1second 9 When battery low the mark will flicker every 1second ...

Страница 10: ...S on the same LAN no matter how far from the UPS Installation procedure 1 Go to the website http www ups software download com winpower htm 2 Choose the operation system you need and follow the instruction described on the website to download the software 3 When downloading all required files from the internet enter the serial No 511C1 01220 0100 478DF2A to install the software When your computer ...

Страница 11: ...y that the load matches the UPS capability specified in the specs When power failure back up time is shorten 1 Overload of the UPS 1 Remove some noncritical load 2 Battery voltage is too low 2 Charge battery 8 hours or more 3 Battery defect due to high temperature operation environment or improper operation to battery 3 Replace with the same type of battery Communication lost between UPS and compu...

Страница 12: ...rn on when UPS work Including in off charging mode and fault mode AUDIBLE ALARM Backup Mode Sounding every 10 seconds Battery Low Sounding every 1 second Overload Sounding every 0 5 seconds Battery replace Sounding every 2 seconds Fault Continuous sounding Buck boost with 70 SPS load Sounding every 0 5sec after 25min And fault after 30 mins PROTECTION Full Protection Discharge Overcharge short cir...

Отзывы: