Page 2: ...ection is found on page Also for further study and information a Bibliography of recommended reading is found at the back of this manual There is a lot of electro medical information freely available today from many varied sources Medical science in this field has certainly advanced tremendously within the last 100 years since it was first proposed Currently there is an enormous worldwide market d...

Page 3: ...m reset 8 Entering Option Code 9 Intensity Adjustment 10 FAQ Frequently Asked Questions 26 Bibliography 27 SECTION 1 BT PRO LCD BASIC UNIT BT 11 Biofeedback 13 SECTION 2 ADDITIONAL PROGRAMS Add On Programs BTAV 14 Magnastim 15 Chakra Balance 17 SleepMate 18 BB Zapper 19 Colloidal Silver 21 Super Sweep Frequency Zapper 22 T E N S 24 Sacred Harmony 25 ...

Page 4: ... involved in the use of the products described here We make no warranty expressed or implied other than that the material conforms to applicable standard specifications The publisher does not accept any responsibility for the accuracy of the information or the consequences arising from the application use or misuse of any of the information contained herein including any injury and or damage to an...

Page 5: ...3 4 9 10 11 DIAGRAM 1 2 Signal input output socket 3 DC 5volt Charge input socket 4 Electrode output socket 5 SELECT switch 6 DOWN switch 7 UP switch 8 POWER ON OFF switch 9 10 Biofeedback sensor pads 11 LCD display ...

Page 6: ...in Charger Power 5V DC 300mA Output Voltage 3 5Vp p 50Vp p bi polar or 27Vmax single polar on battery fully charged Output Short Current 5 mA battery fully charged Bio Feedback Measure Accuracy 10 Input output Connector 3 5mm Stereo Timer Manual set 5 60 minutes 5 min step Display LCD 47mm wide x 14mm high Case Size maximum 60mm width X 107mm high X 20mm depth Weight 85g ...

Page 7: ...will turn off after approximately 10 seconds If no button is pressed within one minute the unit will turn itself off A beeping sound will be heard each time a button is pressed When the program is finished two beep sounds will be heard to indicate that the process has ended and the screen will turn off Pressing the POWER 8 key will instantly terminate any program at any time during processing Plea...

Page 8: ...ery after each use Charge the battery with 5V DC adaptor only or PC USB port power IMPORTANT Please ensure the correct adaptor is used for charging 5 volts ONLY Using the incorrect charging transformer will void all warranty Internal power connection and system reset Disconnect the jumper if machine is not going to used for at least a month or during shipping To reset the system pull out the jumpe...

Page 9: ...ect next digit to enter repeat until all 4 digits are entered Press SELECT 5 for confirm If the code was matched then a beep will sound and option name will be displayed otherwise re enter code again If nothing matched screen will be returned to the beginning When finished press POWER 8 This will turn off machine and matched option code will be permanently saved into memory Fig 4 Check serial numb...

Page 10: ...ll increase the intensity Press the UP button until you can feel a gentle tingle or sensation from the electrodes Please be aware you may not feel this feeling every time you may need to gradually turn the intensity up as the program continues All programs will begin with the intensity FULLY OFF as a safety feature You can test the output signal by inserting the Test Plug supplied Insert this into...

Page 11: ... is displayed press SELECT 5 key again 5 Use UP 7 DOWN 6 key to select the amount of minutes you want the program to run for Fig 11 When correct time is showing press SELECT 5 key to start the program Fig 9 Fig 10 Fig 11 While the program is running the timer counts down in seconds Fig 12 Press UP 7 DOWN 6 key for intensity adjustment Level of Intensity is indicated on the bar above the time displ...

Page 12: ...t 5Hz as being the optimum learn ing frequency Even as you read these words a tiny portion of your brain is physically changing New connections are being sprouted a circuit that will create a stab of recognition if you encounter the words again Supports the body to repair and heal See Bibliography for more information 7 83Hz The 7 83Hz Alpha Theta border brainwave frequency and it s associated wit...

Page 13: ...absolute resistance mode in K ohms readings For percentage mode Fig 17 that value will be from 0 to 99 Lower value means higher resistance more relax If no connection it will display 00 and if short circuit it will display SHOT Intensity bar corresponds to percentage value more bars is high and less bars is low For absolute resistance mode Fig 18 press SELECT 5 key to switch from percentage mode o...

Page 14: ...is designed to run a Light and Sound machine while using C E S frequencies This is a very popular program for those who enjoy the added effect of an audio visual experience while using C E S Cranial Electro Stimulation frequencies Please Note This program is compatible with the following Light Sound machines Photosonix e g Inner Pulse Nova Pro Nova Pro 100 Symantex Procyon Proteus David Paradise m...

Page 15: ...od reputation for grounding anti jetlag anti mind control improved stress tolerance Pituitary stimulation to release growth hormone helps develop muscle recover from injuries rejuvenation effects Leaves you feeling revitalized like you ve spent a day In the country Reports of accelerated healing enhanced learning the earth s natural brain wave Important Using CES Cranial electrostim Ear clips no m...

Page 16: ...headband and crystals driven by electricity of any kind are only some of the many mind machines Negative effects have been reported from the simultaneous use of Magnastim with other mind machines However when they are used about two hours AFTER a Magnastim session their effects can be amplified Frequencies cont To Set up Fig 16 Insert stereo patch lead into the output 4 of the BT Pro LCD unit Inse...

Page 17: ...RWN Crown Sahasrara 172 06 Hz Fig 20 While a program is running screen will display each program s title Fig 20 with clock dots flashing to indicate the timer is counting Press SELECT 5 key will pause current program changes that will stay as current frequency Title also flashes to indicate frequency Press SELECT 5 key again will push frequency change to another one and carry on the cycle Fig 21 T...

Page 18: ...d of the MagnaCoil and TMS adaptor Fig 22 CTNP CATNAP 1 3 59HZ 10 min 2 5HZ 2 min 3 7 8Hz 2 min 4 12Hz 2 min 5 20Hz 4 min SLEP SLEEP 1 20Hz 2 min 2 12Hz 2 min 3 4 9Hz 2 min 4 2 5Hz 3 min 5 0 5Hz 10 min INSN INSOMNIA 1 20Hz 2 min 2 12Hz 2 min 3 7Hz 2 min 4 5Hz 3 min 5 1Hz 3 min 6 0 1Hz 5 min 7 0 05Hz 10 min WKUP WAKEUP 1 10Hz 3 min 2 12Hz 3 min 3 20Hz 3 min 4 40Hz 3 min 5 100Hz 2 min Fig 23 When pr...

Page 19: ...when used according to BBs protocol Nothing is guaranteed Put simply the closer you match this protocol the better results you may achieve Research from Harvard MIT and Albert Einstein College of Medicine has shown that micro currents are known to eliminate viruses parasites fungi bacteria and pathogens in the blood This unit emits those same micro currents It has been a long known fact that silve...

Page 20: ...ed it s just that your body will have adjusted its own skin resistance as a reaction to the zapping Insert the silver electrodes into the cotton sleeves Mix up a small amount of purified water with sea salt and wet the cotton sleeves with this solution This is a saline solution which will aid with conductivity between the electrodes and your skin Do not place the electrodes on bare skin as they ma...

Page 21: ...de of silver of 99 99 purity can be used Lower grade silver or sterling silver will contain nickel which is toxic and must NOT be used Connect the silver rods to the alligator clips plug this lead to the output 4 on the main device Place the silver rods over the top lip of the glass see picture below Use 250ml distilled water Place the silver rods 4 5cm apart Keep them parallel and do not let them...

Page 22: ... waveform to output and contains 5 sub programs After SSFZ is selected press SELECT 5 key go to sub program selection Fig 28 After that press SELECT 5 key will start the program Fig 27 Fig 28 P 1 1 7 minutes 30kHz 2 20 minutes off 3 7 minutes 30kHz 4 20 minutes off 5 7 minutes 30kHz 6 20 minutes off 7 3 minutes 2 5kHz P 2 1 7 minutes 2 3kHz 2 7kHz 2 20 minutes off 3 7 minutes 2 3kHz 2 7kHz 4 20 mi...

Page 23: ...an adjust the intensity but the timers are programmed and cannot be adjusted Each program when completed will switch the unit off Each stage of individual programs will be displayed on the screen until completed Electrodes High quality elastic electrodes are supplied for use with SSFZ option Make sure the wrist is clean and free from grease or dirt Place the metal side of the elec trode on the ins...

Page 24: ... frequencies changed over when current cycle finished Fig 30 Setup Turn power on press up down buttons untill TENS is selected press SELECT 5 to con firm Then select program P_1 or P_2 by press UP 7 DOWN 6 To confirm by press SELECT 5 then press UP 7 DOWN 6 to select timer from 5 60 minutes After timer select press SELECT 5 to start the program The unit will automatically switch off after set prog...

Page 25: ...mer control and will run non stop until actively switching the unit off to cease the function By pressing SELECT during each sequence the frequency will remain current and frequency title will flash Press SELECT 5 again will skip to next frequency and LCD screen will display corresponding frequency title as well fig 32 Fig 31 Fig 32 Please note Make sure that The BLACK TMS unit 24 volt is used wit...