background image

 

 

 

 
 
 
 

 

 
 
 
 

Bedienungsanleitung 

Operating Instructions 

 
 
 

Elektronisches Vorschaltgerät

 

Electronic Ballast 

 

EB 1200/1800 Event Three 

 
 
 
 

- flicker free - 

 
 
 
 
 

Arnold & Richter Cine Technik 

Lighting Division 

Pulvermühle 

 

D-83071 Stephanskirchen

 

 

 

Tel. (0)8036-3009-0 

 

 

Fax (0)8036-2471

 

L2.76610.0

 

 

Summary of Contents for EB 1200 Event Three

Page 1: ...ng Instructions Elektronisches Vorschaltgerät Electronic Ballast EB 1200 1800 Event Three flicker free Arnold Richter Cine Technik Lighting Division Pulvermühle D 83071 Stephanskirchen Tel 0 8036 3009 0 Fax 0 8036 2471 L2 76610 0 ...

Page 2: ...rät mit Scheinwerfern 16 8 Anschlüsse auf der Geräterückseite 16 9 Ansicht Gerätefront 17 10 Bedienelemente Modul 17 English Contents Page 1 General Remarks 10 2 Important Safety Instructions 10 3 Product Description 11 4 Start Up Procedure 12 4 1 Energizing System 12 4 2 Operation of Module 12 4 3 Control of Light Intensity 13 4 4 Remote Control DMX 512 13 5 Technical Data 14 6 Trouble Shooting G...

Page 3: ... Anhang G 2 3 Für den Lampenwechsel einer an das Vorschaltgerät angeschlossenen Leuchte ist das Vorschaltgerät auszuschalten und die Leuchte elektrisch vom Vorschaltgerät zu trennen Leuchtensteckverbinder 2 4 Vor dem Lösen bzw Anschließen des Lampenkabels an der Lampensteck verbindung ist das Gerät auszuschalten Es dürfen nur original ARRI Lampenkabel mit für die Lampenleistung zugelassenem Quersc...

Page 4: ...nter Türen quetschen oder anderweitig einklemmen Gerät vom Netz trennen wenn es nicht benötigt wird Gerät nur unter den in der Bedienungsanleitung vorgegebenen Umgebungsbedingungen betreiben 3 Produktbeschreibung Das Elektronische Vorschaltgerät EB 1200 1800 Event Three von ARRI ist für den Betrieb von bis zu drei 1200 W oder 1800 W Scheinwerfern über ein ARRI Multicore System vorgesehen siehe Abb...

Page 5: ... W als auch 1800 W Lampen eingesetzt werden Die eingesetzte Lampe wird nach dem Starten des EVGs elektronisch erkannt EVG mit Netzspannung versorgen Die drei grünen LEDs L1 L2 und L3 auf an der rechten Seite der EVG Frontplatte leuchten wenn an den jeweiligen Phasen Netzspannung 180Veff gegenüber dem Nulleiter anliegt Die rote LED MAINS FAULT zeigt an das sich das Gerät wegen einer Netzüberspannun...

Page 6: ... Fernsteuerung Das EB 1200 1800 EVENT THREE kann über eine digitale DMX 512 Fernsteuerung bedient werden Die Anschlußbuchsen für die Fernsteuerung befinden sich auf der Geräterückseite Mit dem dreistelligen dezimalen Schalter an der Gerätefront werden die Adressen der Module eingestellt Die Fernsteuerung jedes Moduls erfolgt über zwei DMX Kanäle Der erste Kanal dient der Dimmung Der zweite auf der...

Page 7: ...stung 7 800 VA max Leistungsfaktor cos ϕ 0 98 Netzstecker CEE 16 A 3 N PE Lampenanschluß Lampenleistung 3x 1200 W oder 3x 1800 W konstant geregelt Stromverlauf Rechteckstrom ca 200 Hz Dimmung Bereich 50 bis 100 des Nennwertes der Lampenleistung Zündung Heiß und Kaltstart Lichtrippel typ 3 Abmessungen B H T 19 483 mm 4 HE 177 mm 530 mm Gewicht 24 kg Schutzart IP 20 ...

Page 8: ...der Fehler in jeder der drei Einheiten vorliegen Eine verdächtige Leuchte sollte nicht mit einem anderen EVG erneut gestartet werden andernfalls könnten zwei zerstörte EVG das Ergebnis sein Um zu Prüfen ob ein EVG funktionstüchtig ist ist eine geprüfte Leuchte direkt ohne Verlängerungskabel an das EVG zu schalten 6 9 Wenn das EVG nach einigen Minuten abschaltet können verschiedene Ursachen vorlieg...

Page 9: ...Deutsch 9 LICHTTECHNIK ...

Page 10: ...mp 2 4 The Electronic Ballast must be switched off before connecting or disconnecting either head or supply cable Do not use other than original ARRI cables and connectors with permitted cross section of the leads The ballast can only be used with a suitable multicore cable system see fig 1 page 16 Using other than original ARRI cables or luminaires may cause injury to the user as well and or dama...

Page 11: ... edges clamp them under doors or clamp them in any other way Switch off EB when it is not needed 3 Product Description The Electronic Ballast ARRI EB 1200 1800 Event Three is part of an optimized lighting system along with a suitable multicore cable system and up to three luminaires see fig 1 page 16 The ARRI EB 1200 1800 Event Three consists of 3 modules see fig 3 page 17 Each modul can drive one...

Page 12: ...heck earth protection If correct the green LED PE on front plate illuminates If not disconnect EB from mains pull out line plug and check power supply and socket 4 2 Operation of 1800 W Module The LEDs 1200 W and 1800 W indicate the nominal power of the detected luminaire resp inserted lamp To switch a lamp on set the corresponding ON OFF switch to ON position The LED MODULE goes on The nominal po...

Page 13: ...his module results of the dimming address incremented by one The next following address will be the dimming address of module 2 As long as the ballast receives valid DMX signals the modules are controlled by the DMX remote control In this case the on off switch and the dimming potentiometer at the front panel of the ballast have no function To switch the ballast on a value between 128 and 255 must...

Page 14: ...max Power Factor cos ϕ 0 98 Line Connector CEE 16 A 3 N PE Lamp connection Lamp Power 3x 1200 W or 3x 1800 W constant control Current Characteristic square wave approx 200 Hz Dimming Range 50 100 of nominal lamp power Starting cold start and hot restrike typical light ripple typ 3 Dimensions width height depth 19 483 mm 4 HE 177 mm 530 mm Weight 24 kg Protective rate IP 20 ...

Page 15: ... with another ballast you may end up with two faulty ballasts To check if a ballast is good run it with a known good luminaire and known good multicore cable and splitbox 6 9 If a module cuts out after running a few minutes there are a number of possible failures The lamp itself may be faulty or at the end of its life The thermal cutout in the module may have activated due to extreme ambient tempe...

Page 16: ...8 Event Multicore 6 or 8 channels wiring 1 9 minimum cross section 2 5 mm Abb Fig 1 Event Licht System mit 1200 W und 1800 W Leuchten Event Lighting System with 1200 W and 1800 W Lampheads 1 16 DMX OUT DMX IN 180 250 V 1 N PE 50 60Hz 14 5 10 5 A 7800 VA I IP 20 22 kg Mains U I Pmax Prot Cl 187000111 Fabr Nr cos ϕ 0 98 EB 1200 1800 Event Three L2 76610 0 Type ld Nr MADE IN GERMANY Vor Öffnen des Ge...

Page 17: ...1200 1800 W I O MAX MIN DMX MODULE LAMP ON TEMP 1200 W 1800 W ELECTRONIC BALLAST MODULE 1200 1800W I O Modul Nr Module No Dimmadresse Dimming Address Schaltadresse On Off Address 1 X 1 X 2 X 3 X 2 3 X 5 X 4 X DMX Adressvergabe DMXAddress Assignment Abb Fig 3 Ansicht Gerätefront Front View of Ballast MAX MIN DMX MODULE LAMP ON TEMP 1200 W 1800 W ELECTRONIC BALLAST MODULE 1200 1800 W I O Dimmpotenti...

Reviews: