            OWNER’S MANUAL 

 
 

Models: AC110, AC125, AC150 made from 2003 through 2010 

 
 
 
 
 
 
 
 
 
 

                     
 
 
 
 
 
 
 
 

           Manufacturing High Quality, High Efficiency 

                                   Heat Pump Pool Heaters 
 

 

               TABLE OF CONTENTS               

 

 

 

 

SAFETY CONSIDERATIONS 

 

2

 

 

 

 

         

INSPECTION 

 

 

 

2

 

 

 

                        

GENERAL INFORMATION 

 

2

 

 

 

 

                 

INSTALLATION 

 

 

2

 

 

 

 

 

WATER FLOW & CONNECTIONS 

2-3

 

 

ELECTRICAL CONNECTIONS   

4

 

MODES OF OPERATION 

 

5

 

WIRING DIAGRAMS 

 

 

6

 

ELECTRONIC CONTROL PANEL             7

 

CHEMICAL USE 

 

 

8

 

START-UP 

 

 

 

9-10

 

MAINTENANCE 

 

 

10-11

 

TROUBLESHOOTING CHECKLIST 

11-12

 

CALLING FOR SERVICE 

 

12

 

WARRANTY 

 

 

 

13

 

WARRANTY REGISTRATION   

14

 

 

   

SAFETY CONSIDERATIONS 

 

          Proudly Made in the USA 

[email protected]

 

 

www.aquacomfort.com/service-and-support/

 

 

 (888) 475-7443  

 

 

ALL IN-GROUND 

MODELS 

 

 

 

INSTALLATION, 

OPERATION, 

MAINTENANCE      

& SERVICE 

Summary of Contents for AC110

Page 1: ...LOW CONNECTIONS 2 3 ELECTRICAL CONNECTIONS 4 MODES OF OPERATION 5 WIRING DIAGRAMS 6 ELECTRONIC CONTROL PANEL 7 CHEMICAL USE 8 START UP 9 10 MAINTENANCE 10 11 TROUBLESHOOTING CHECKLIST 11 12 CALLING FOR SERVICE 12 WARRANTY 13 WARRANTY REGISTRATION 14 SAFETY CONSIDERATIONS Proudly Made in the USA support aquacomfort com www aquacomfort com service and support 888 475 7443 ALL IN GROUND MODELS INSTAL...

Page 2: ...the following Heater must be located outdoors Minimum of 24 of clearance on access service side of heater Minimum of 18 of clearance on all three air intake sides of heater Minimum of 48 of clearance for air discharge top of unit The heater should sit on a solid level surface sufficient above grade to prevent water from entering it and allowing condensate to drain from base The length of water pip...

Page 3: ...lowed run the filter pump and check the entire system for water leaks Make sure filter is clean and there are no obstructions in the filtering system Proper water flow is essential to the performance of your heater The minimum flow rate is 20 GPM TYPICAL WATER FLOW CONNECTIONS ...

Page 4: ... on left side of hinged electrical enclosure 3 Route weather tight flexible conduit through opening at base of unit Connect conduit to the bottom of the electrical enclosure using a weather tight fitting A knockout is provided next to the main contactor to accept a weather tight fitting Mounting conduit directly to the electrical enclosure will ensure a moisture tight seal extending the life of th...

Page 5: ...o turn the heater on and off a normally open dry contact can be made at terminals 18 and 19 on the bottom right of the electronic control board The red jumper at the top of the control board must then be cut to activate this system In the case of a remote thermostat where the temperature will be regulated externally set the Pool Mode to the OFF position and the Spa Mode to 104 F 40 C The heater wi...

Page 6: ...6 ...

Page 7: ...econds then revert back to the actual pool or spa water temperature Selecting Pool or Spa Mode Press the SELECT KEY until you reach P_S Pressing the UP or DOWN key will allow you to enter either POOL or SPA mode Green LED indicator lights will verify the mode selected FIL MODE MUST BE IN THE OFF POSITION OR A FLO3 ERROR CODE WILL BE DISPLAYED Selecting temperature in Fahrenheit or Celsius The fact...

Page 8: ...c chlorinators must be piped downstream from the heater A check valve must be installed between the chlorinator and heater to prevent raw chlorine from draining back into the heater A chemical trap may be piped at least six 6 inches above the chlorinator See piping diagram B Always maintain the following water quality requirements PH LEVEL 7 4 to 7 8 CHLORINE CONCENTRATION 1 to 5 PPM TOTAL ALKALIN...

Page 9: ...may require you to run your heater and filter pump continuously for at least 24 hours or more depending on the following factors Temperature difference between actual water temperature and desired water temperature Size of pool Ambient air temperature the cooler the air temperature the longer the heating time Heat loss evaporative convective radiative and conductive A pool cover solar blanket may ...

Page 10: ...water pressure switch will shut down the unit When normal water flow resumes the heater will automatically restart itself Other analyzer codes include FL3 LP3 LP dPO PO dPC Pc PLE CSE and SPi The TROUBLESHOOTING CHECKLIST on page 11 goes into further detail on these analyzer codes MAINTENANCE WARNING DISCONNECT ELECTRICAL POWER TO UNIT BEFORE STARTING ANY MAINTENANCE TO PREVENT SERIOUS INJURY FROM...

Page 11: ...re are no restrictions to its airflow Certain ambient air conditions may cause the heater to go into defrost mode displayed on the control panel as FS NOTE IT IS NORMAL FOR WATER TO DRIP FROM THE DRAINHOLES AT THE BASE OF THE HEATER THE UNIT PRODUCES CONDENSATE WHEN IT OPERATES Analyzer Codes FAILURE LOCK OUT This feature is for the protection of the heater If the same failure occurs three 3 times...

Page 12: ...l the error message disappears The control will be reinitiated to factory default Re enter the setpoints SPi Defective controller remove power and restart If error is still present replace controller CALLING FOR SERVICE Please eliminate any water flow problems before calling for service If you are unable to contact the installing agent please go to www aquacomfort com service and support to contac...