Summary of Contents for AP-AB1205

Page 1: ...AP TR Shanghai Anping Static Technology Co Ltd High Efficient Electroshock proof AP AB1205 Ion Bar AP T ...

Page 2: ...ly used in printing UV flatbed industry Effectively solve the problem caused by static electricity Prevent sticking Prevent uneven scattering Prevent adhesion of objects Static removal Control ink splashing ...

Page 3: ...High efficient Safe Static removal ...

Page 4: ...harge speed Ion balance ion output frequency adjustable Intelligent Control HV Positive high voltage Positive voltage working time Negative voltage working time HV Negative high voltage HV Positive high voltage Positive voltage working time Negative voltage working time time HV Negative high voltage HV Positive high voltage HV Negative high voltage HV Positive high voltage Positive voltage working...

Page 5: ... days The cleaning function will alarm when the countdown is 0 days Power off and restart to restore the set time The cleaning function becomes invalid if the value is set to 0 days Adjust frequency FREQ Press FREQ first then press to increase or decrease the frequency of positive and negative ions output Adjust ion balance voltage IBN Press IBN first then press when the positive voltage on flat p...

Page 6: ...working time Negative voltage working time HV Positive high pressure HV Negative high pressure Comparison with traditional AC The pulsed AC method alternately applies and high voltage to one electrode needle to generate two polar ions Compared with the AC method the ion generation efficiency is higher Electrostatic elmiination ability can be fully plated on matter for short or long distance Beside...

Page 7: ...0 1 0 1 13 7 150 2 1 2 3 19 9 100 150 5 1 4 2 2 75 0 0 5 1 0 9 9 150 6 0 5 4 21 3 Test Conditions Test standard ANSI ESD STM3 1 SJ T 11446 2013 Test instrument Trek157 static tester Test voltage 1000V 100V attenuation Test environment humidity 50 5 temperature 23 3 Ion bar length 410mm Working frequency 30Hz 150mm 150mm Flat tester The test data diagram is as follows test distance 100mm ion bar le...

Page 8: ...gth of the power cord is 1500mm and the low voltage wiring of 24V can eliminate the aging phenomenon of the cable caused by the discharge and the impact on the peripheral equipment which can build a highly reliable system Working status visualization Red light alarm when high voltage abnormal CE certification It can effectively prevent the external electromagnetic interference from affecting the n...

Page 9: ...12 12 4 square nuts Working status indicator Needle holder and electrode needle Strip grounding electrode Front Back M5 12 12 4 square nuts DC24V high flexible towline power cord Working status indicator Needle holder and electrode needle Strip grounding electrode Product Size Product Details Specification Details Parameter Size ...

Page 10: ...ion distance 30 100mm Ion balance 30V AVE Discharge speed 1S Test distance 100mm Status indicator Green light normal Blue light standby Blue light flashing debugging cleaning Red light Abnormal high voltage Working temperature 0 50 Working humidity 70 Dimensions L W H 200 300mm Needle spacing 25mm 350 3000mm Needle spacing 50mm 35mm 63 5mm Bar material Flame retardant PVC AL SUS Packaging accessor...

Page 11: ...end of the network cable into the DC24V adapter power supply and the other end into the aviation socket on the ion bar Use the remote control to adjust the voltage output parameters under the appropriate air pressure When the positive voltage on the surface of the flat panel detector or the object to be discharged is large press to adjust IB when the negative voltage on the flat panel detector or ...

Page 12: ...er if you want to see the adjustment results 2 The ion bar grounding electrode is not allowed to be covered by other objects 3 3 It is advisable to install two ion bars side by side with an interval of more than 100mm Two ion bars should be staggered by more than 100mm if they are to be installed face to face 4 It is advisable to be more than 200mm away from obstacles such as walls 5 For the safe ...

Page 13: ...pment in environment where humidity is 70 4 It is strictly forbidden to use this equipment in flammable and explosive environments 5 Unauthorized disassembly of the product is strictly prohibited internal maintenance and repair must be performed by professionals 6 The product is strictly prohibited to touch liquid during use otherwise an abnormality may occur and cause electric shock or fire 7 Pow...

Page 14: ...n 1 AP T makes a commitment to the customer that any defective parts inspected by AP T will be repaired or replaced free of charge within one year from the date of purchase However this commitment does not apply to 1 The device is incorrectly used or installed 2 Damage caused by negligence or accident during use 3 Modified disassembled or repaired by other service departments not authorized by Anp...

Page 15: ...Creates Value Speciality Creates Value Shanghai Anping Static Technology Co Ltd Tel 021 64517676 Fax 021 64517673 Postcode 200233 Website www ap static com Address 3 F Building 27 No 69 Guiqing Road Shanghai China ...