background image

is a trademark of Apache Pipeline Products and protected by U.S. Patent 5263220

INSTALLATION - REASSEMBLY 

TECHNICAL DATA

1. 

Reinstall DUST SEAL to LOWER HOUSING 

(Figure 7)

.

2. 

Using (2) screws provided, install UPPER HOUSING ASSEMBLY to the LOWER HOUSING 

(Figure 7)

.

3. 

With the flag in the “UP” position, reinstall FLAG PUSH ROD and set RESET ROD back into 

place 

(Figure 7)

.

4. 

Set LOAD SPRING onto RESET ROD 

(Figure 7)

.

5. 

Install LID using two (2) screws provided 

(Figure 7)

.

6. 

Screw RESET BUTTON onto RESET ROD ensuring it turns freely 

(Figure 7)

.

7. 

Reinstall LIMIT SWITCH

8.

 Push down on RESET BUTTON to fully extend PLUNGER into pipe bore. Put FLAG into 

“DOWN” position 

(Figure 7)

9. 

Adjust MAIN ASSEMBLY by turning UPPER HOUSING clockwise or counter-clockwise to 

attain INSTALL HEIGHT marked on TAG located on UPPER HOUSING ASSEMBLY 

(Figure 8). 

LOCK SCREW may need to be loosened. 

NOTE: 

See illustration for detailed drawing.

10. 

Tighten LOCK SCREW to secure MAIN ASSEMBLY and slide DUST SEAL on to 2” NPT 

ADAPTER 

(Figure 9).

LSX Limit Switch - weather sealed, explosion proof enclosures meet
NEMA standards: 1, 3, 4, 6, 9 and 13. UL listed and CSA certified:
Class I, Div.1, Groups B,C and D. Class II, Div.1, Groups E, F and G.

Install Height Adjustment

Electrical Ratings

10 amps continuous carry. Circuits on any pole must be the same polarity.

AC Volts                  

Pilot Duty: 600VAC, 720VA

Electrical

Rating

Circuitry

VAC

Amps at 0.35

Power Factor

Make    Break

Double Pole

Double Throw

120
240
480
600

30
15

7.5

6

3

1.5

0.75
0.60

B

DC Volts                         

Pilot Duty: 240VAC, 30 watts

Electrical

Rating

Circuitry

VDC

Make and Break Amps

Inductive    Resistive

Double Pole

Double Throw

120
240

0.25
0.15

0.80
0.40

B

4L - Momentary

Double-pole, 2 N.O., 2 N.C.

ELectrical Rating B

1

2

3

4

5

6

7

8

 IMPORTANT:

 Detection of pig’s passage is dependent on 

proper INSTALL HEIGHT. Incorrect INSTALL HEIGHT could void 
the warranty.

Please Contact Apache for technical assistance

Phone: (780) 416-4850  Fax: (780) 416-4829  Email: [email protected]

Electrical Diagram

INSTALL

HEIGHT

INSTALLATION INSTRUCTIONS

Series 53 Visual/Electrical Indicator 