3-1
ML-605M Series Electro-Mechanical Lock
Copyright © All Rights Reserved. P-MU-ML-605 Published: 2020.12.07
Unit: mm
1
2
Installation Instruction
Dimension
Specification
Packing Contents
Stud Bolt Position
Lock Bolt
Nib
Strike Plate
Euro profile
key cylinder hole
Caution:
Do not completely remove screw 2 (as marked in the figure)
as the interior solenoid might fall off.
Version Changeable:
Take out the Screw 1 , release screw 2 , move the
position and then tighten both screws.
“Fail-Safe”
(Power to Lock)
“Fail-Secure”
(Power to Open)
For fail-safe mode
For fail-secure mode
Operating Voltage: 12~24VDC/AC ±10%
Current Draw: 250mA/12VDC; 150mA/24VDC
Operating Temperature: 14°F to 120°F (-10°C~+49°C)
Humidity: 0~85% non-condensing
Version Changeable: Fail-safe or Fail-secure
Lock bolt sensor switch output: SPDT, 3A/125VAC
Latch Throw:16mm
Solenoid testing: Tested to 250,000 cycles
Resistance against door being forced :
1500 lbs (static force); 70 ft-lbs (dynamic force)
Backset:
ML-605M-30: 30mm
ML-605M-35: 35mm
21
28
100
125
150
230
78
2
35
54
Backset
114.5
250
275
21
28
100
125
150
230
78
2
30
49
Backset
114.5
250
275
ML-605M-30
ML-605M-35
3
3