• Selectable wireless panel and sensor compatibility
• Translator or repeater operation
• Rechargeable backup battery
• Cover tamper
•
Certified to UL1023, ULC1023, UL1610, and ULC S304
PANEL ENROLLMENT
(For full sensor enrollment instructions, refer to Advanced Setup, step 3
A
Enroll Translator into Panel.
• Trip the translator tamper to enroll the translator into the panel (For
Honeywell® and 2GIG®
panels select loop 1).
-or-
• Enter ID into panel. The translator’s ID is printed on the bar code label.
B
Enroll Sensors into Panel
• With the translator cover open, trip each sensor to enroll it into to the panel.
• Finish setup of each sensor at the panel.
Features
FINISH
A
With the translator cover open, perform a panel sensor test.
B
Close the cover. Test and verify proper operation of the sensors at the panel.
C
Cut the lock wire to lock the translator (For more information on locking, refer to Advanced Setup, step 4
).
D
Secure cover with screw.
DIAGRAM
Wall mounting
screw locations
MOUNT AND WIRE
A
Select a mounting position and location.
B
Connect the power supply to the translator.
1
2
3
4
TRANSLATOR CONFIGURATION
A
Select the brand of panel that the translator must
talk to using the “PANEL SELECT” knob.
B
Select the brand of sensors that the translator must
listen to using the “SENSOR SELECT” knob.
C
Sensor configuration: The translator must learn
the sensors that are to be translated or repeated.
a) Press the “CONFIGURE” button to enter configuration mode.
b) Tamper or trip all sensors that are to be included in the system
c) Press the “CONFIGURE” button to exit configuration mode
.
Quick Setup
(Mounting hardware not included. Use two
#4 or # 6 screws for mounting )
Wall Tamper
(Do not overtighten
mounting screw)
Installation Guide: RE524X & RE524XC Universal Wireless Translator™