Rack Mount Power Supplies 

Installation Guide 

Models Include: 

VertiLine33D 

- 12VDC @ 8A 

- Sixteen (16) PTC protected outputs 

VertiLine33TD 

- 12VDC @ 16A 

- Sixteen (16) PTC protected outputs 

VertiLine63D 

- 24VDC @ 8A 

- Sixteen (16) PTC protected outputs 

VertiLine63TD 

- 24VDC @ 16A 

- Sixteen (16) PTC protected outputs 

More than just power.

TM 

Rev. 090810 

                    Available from A1 Security Cameras 

    www.a1securitycameras.com email: [email protected]

Summary of Contents for VERTILNE33D

Page 1: ... outputs VertiLine33TD 12VDC 16A Sixteen 16 PTC protected outputs VertiLine63D 24VDC 8A Sixteen 16 PTC protected outputs VertiLine63TD 24VDC 16A Sixteen 16 PTC protected outputs More than just power TM Rev 090810 Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...

Page 2: ...isk of fire or electric shock do not expose the unit to rain or moisture This installation should be made by qualified service personnel and should conform to the National Electrical Code and all local codes Installation Instructions 1 Attach mounting brackets to Vertiline unit for rack or wall mount installation Figs 3 4 pg 7 Affix rubber pads to Vertiline for shelf installation Fig 5 pg 7 2 Secu...

Page 3: ...oad condition To reset the PTC 1 Set illuminated master power disconnect circuit breaker to the OFF position Fig 1c pg 4 2 Eliminate the trouble condition short circuit or overload 3 Allow 1 minute for PTC to cool off reset 4 Set illuminated master power disconnect circuit breaker to the ON position Fig 1c pg 4 5 All power LEDs will illuminate indicating power has been restored to all outputs Fig ...

Page 4: ...tiline33D Vertiline33TD Vertiline63D and Vertiline63TD rear 1a 1b 1c 1d 1a LED s 1 8 Power LED indicators 1b Power Outputs 12VDC or 24VDC 1c Illuminated master power disconnect circuit breaker switch OFF position Circuit breaker tripped Switch not illuminated RESET ON position Switch illuminated 1e Removable Terminal Block Available from A1 Security Cameras www a1securitycameras com email sales a1...

Page 5: ...ig 2 12VDC Vertiline33D Vertiline33TD 12VDC Vertiline33D Vertiline33TD or 24VDC Vertiline63D Vertiline63TD or 24VDC Vertiline63D Vertiline63TD Power Outputs to Devices Power Outputs to Devices Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...

Page 6: ...eable parts inside Refer servicing to qualified service personnel 1U EIA 19 Rack Mount Chassis Mechanical Drawing and Dimensions 1 625 x 19 125 x 8 5 41 3mm x 486mm x 216mm REAR 1 625 41 3mm ON 8 5 216mm 0 75 19 05mm 19 125 486mm TOP BOTTOM FRONT Illuminated master power disconnect circuit breaker OFF position Switch not illuminated Outputs not powered RESET ON position Switch illuminated Outputs ...

Page 7: ...Front Left B Remove A Wall Mount Installation 1 Attach mounting brackets A on the left and right side of rack chassis using two 2 flat head screws B included Fig 4a 2 Secure unit to wall with appropriate screws hardware not included Fig 4b Caution It is necessary to make sure mounting screws are securely fastened to a beam when installing Fig 4 Fig 4a Fig 4b A B Shelf Installation 1 Position and a...

Page 8: ...0 USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIVertiline33DSeries F14P MEMBER 8 Vertiline33D VertiLine33TD Vertiline63D VertiLine63TD Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...