Instruction Manual – PLM120
Caution : Before assembling and operating please
read the entire manual
20-Watt Low Voltage Power Beam™ Lights must be operated fully submerged
under water. Must be used with a transformer at all times, an Alpine transformer is
recommended to use this light.
Must be operated with a transformer (not included):
Before Reading instructions below, this light MUST BE used with a transformer. Suggested use with an
Alpine transformer. Please use a transformer with the correct wattage and never exceed the maximum
wattage indicated on the transformer.
Operating Instructions:
•
Before plugging in the unit, be sure the input voltage indicated on your transformer is the same as
your local power supply. If not, please do not operate the light until you obtain the appropriate
transformer from your local dealer.
•
To reduce the risk of electrical shock, inspect all cords for damage before installation.
•
Plug the connector of the Power Beam™ Light into the socket on the transformer and screw the
coupling until tight.
•
Plug the transformer into the nearest 120-volt outlet. Your Power Beam™ light should light up.
Changing the MR11 Bulb or Colored Lenses to your Power Beam™:
•
To replace the MR11 12 volt 20 watt halogen bulb, first make sure to unplug the transformer and
remove it from the water (if submerged).
•
After allowing a sufficient amount of time for the light to cool, let it dry and remove the lens
retainer from the Power Beam™ light by pushing on it and turning counter-clockwise quickly.
•
Remove the lens carefully and make sure the “O” ring stays in place and is not lost during this
process.
•
Gently pull out the socket and remove the MR11 bulb and replace with the new MR11 12 volt 20
watt bulb by aligning the pins of the bulb into the socket. Gently push the new bulb down, DO
NOT force it. Turn the MR11 12volt 20 watt bulb around if it does not fit easily.