background image

 

 

 

 

V00

 

SMILE-G3-S5 /SMILE-G3-S3.6/SMILE-G3-B5 

INSTAL    L

MI  

LE-G3-S5-INV

Summary of Contents for SMILE-G3-B5

Page 1: ...V00 SMILE G3 S5 SMILE G3 S3 6 SMILE G3 B5 INSTAL L MI LE G3 S5 INV ...

Page 2: ... copyright of Alpha ESS Co Ltd with all rights reserved Please keep the manual properly and operate in strict accordance with all safety and operating instructions in this manual Please do not operate the product before reading through the manual ...

Page 3: ...05 2 4 Symbols on the label 08 PRODUCT INTRODUCTION AND APPLICATION SCENARIOS 10 3 1 Inverter Description 10 3 2 Battery Pack Description 12 3 3 Application Scenarios 13 STORAGE 15 4 1 Inverter Storage 15 4 2 Battery Storage 15 UNPACKING 16 5 1 Checking the Outer Packing 16 5 2 Scope of Delivery 16 MOUNTING 18 6 1 Requirements for Mounting 18 6 2 Preparing Tools and Instruments 20 6 3 Mounting the...

Page 4: ... 9 1 Checking Before Power On 57 9 2 Check the Running State 57 9 3 Powering Off the Product 58 MAINTENANCE AND TROUBLESHOOTING 59 10 1 Routine Maintenance 59 10 2 Troubleshooting 60 UNINSTALLATION RETURN 65 11 1 Removing the Product 65 11 2 Packing the Product 65 11 3 Disposing of the Product 65 SPECIFICATION 66 12 1 Datasheet of SMILE G3 INV 66 12 2 Datasheet of Battery Pack SMILE G3 BAT 10 1P 68...

Page 5: ...t do not require any particular qualification are not marked and can also be performed by end users Qualified persons must have the following skills Knowledge of how an inverter works and operates Training in how to deal with the dangers and risks associated with installing and using electrical devices batteries and systems Training in the installation and commissioning of electrical devices and sys...

Page 6: ...or SMILE G3 S3 6 INV 3 6kW DC coupled hybrid inverter Outdoor SMILE G3 B5 INV 5kW AC coupled hybrid inverter Outdoor SMILE G3 BAT 10 1P 10 1kWh LFP battery Outdoor NOTICE NOTICE indicates a situation which if not avoided can result in property damage INFORMATION provides tips which are valuable for the optimal installation and operation of the product ...

Page 7: ...permitted with the express written permission of AlphaESS Unauthorized alterations will void guarantee and warranty claims AlphaESS shall not be held liable for any damage caused by such changes Any use of the product other than that described in the Intended Use section does not qualify as appropriate The enclosed documentation is an integral part of this product Keep the documentation in a conve...

Page 8: ...rator is not required during normal operations Use FM 200 or CO2 extinguisher for battery fire Use an ABC fire extinguisher if the fire is not from battery and not spread to it yet Firefighting instructions 1 If fire occurs when charging batteries if it is safe to do so disconnect the battery pack circuit breaker to shut off the power to charge 2 If the battery pack is not on fire yet extinguish the fire ...

Page 9: ...components or cables are touched High voltages are present in the conductive components or cables of the product Touching live parts and cables results in death or lethal injuries due to electric shock Do not touch non insulated parts or cables Disconnect the product from voltage sources and make sure it cannot be reconnected before working on the inverter or the battery pack After disconnection w...

Page 10: ...yte rinse the affected areas immediately with water and consult a doctor without delay DANGER Danger to life due to electric shock when touching live system components in case of a ground fault If a ground fault occurs parts of the system may still be live Touching live parts and cables results in death or lethal injuries due to electric shock Disconnect the product from voltage sources and make su...

Page 11: ...electronic components can cause damage to or destroy the inverter through electrostatic discharge Ground yourself before touching any component NOTICE Damage due to cleaning agents The use of cleaning agents may cause damage to the product and its components Clean the product and all its components only with a cloth moistened with clear water ...

Page 12: ...e lethal electric shocks are pre sent in the live components of the inverter Prior to performing any work on the inverter disconnect it from all voltage sources as described in this document WEEE designation Do not dispose of the product together with the household waste but in accordance with the disposal regulations for electronic waste applicable at the installation site Observe the documentati...

Page 13: ...k of chemical burns Risk of explosion Observe the documentation Risk of electrolyte leakage CE marking The product complies with the requirements of the applicable EU directives Refer to the instruction for operation Use eye protection Fire naked light and smoking prohibited No nearing Do not dispose of the battery pack together with the house hold waste but in accordance with the locally applicab...

Page 14: ...ignals Five LED indicators and one reset button are provided on the display panel These LED indicators provide information about the operational status of the system Status Explanation Status Explanation When White light The system works normally When White light The battery pack works normally When no light The system is fault When no light Battery is not working normally ...

Page 15: ...N AND APPLICATION SCENARIOS Status Explanation Status Explanation When White light Meter communication works normally When White light Disconnect to the server When no light Meter lost When no light Disconnect to the server ...

Page 16: ...1P Battery pack appearance and dimensions Battery Pack Dimension W H D SMILE G3 S5 INV OUTDOOR 610 780 212 mm SMILE G3 S3 6 INV OUTDOOR 610 780 212 mm SMILE G3 B5 INV OUTDOOR 610 780 212 mm Four LED indicators are provided on the display panel Different colors represent different states green for SOC yellow for Protection red for Error ...

Page 17: ...tor will flash every 3s 55 SOC 80 The first second and third line of the LED indicator are always on When the battery is being charged and the SOC isbetween 55 and 80 the third line of the LEDindicator will flash every 3s 80 SOC 100 All the LED indicators are always on When the battery is being charged and the SOC is between 80 and 100 the fourth line of the LEDindicator will flash every 3s 3 3 Applic...

Page 18: ... Indicates a power cable Indicates a signal cable DC coupled Storage System Scheme Indicates a power cable Indicates a signal cable AC coupled Storage System Scheme Indicates a power cable Indicates a signal cable Hybrid coupled Storage System Scheme ...

Page 19: ...he battery pack where it should be minimal dust and dirt in the area 5 Handle batteries with caution to avoid damage 6 The storage environment requirements are as follows Ambient temperature 10 55 C recommended storage temperature 15 30 C Relative humidity 15 85 Place batteries in a dry and clean place with proper ventilation Place batteries in a place that is away from corrosive organic solvents ...

Page 20: ...nd any externally visible damage Contact your distributor if the scope of delivery is incomplete or damaged Items only for SMILE G5 S5 S3 6 INV SMILE G3 S5 S3 6 B5 INV Hybrid Inverter Inverter X1 TOP decorate plate X1 Right decorate plate X1 Left decorate plate X1 Left Bracket X1 Right Bracket X1 PV PV Connectors X2 AC Connector BACK UP Connector WiFi Module X1 GRID CT PowerCable X1 PowerCable X1 ...

Page 21: ...le X1 Guide Screw M5 10 X8 Indoor Use Foot Pad X2 Outdoor Use Ring Terminal Lug X2 Quick Installation Guide X1 Screw M6 12 X2 Outdoor Use Screw M5 10 X6 OutdoorUse Screw M4 12 X3 Outdoor Use Upper Cover Plate X1 SMILE BAT 5PH Battery Pack X1 Wall Anchor ST6 55 X6 Power Cable X1 Power Cable X1 Battery COM Cable X1 Battery Positioning Paper Plate X1 Ring Terminal Lug X2 Screw M5 10 X2 Upper Cover Pl...

Page 22: ...Screw M5 12 X3 Side Gasket X1 ...

Page 23: ...n When mounted under direct sunlight the power of the product may be de rated due to additional temperature rise Mount the product in a sheltered place or mount an awning over the product The optimal temperature ranges for the battery pack to operate is from15 to 30 Do not expose or place near water sources like downspouts or sprinklers If the battery pack is mounted in the garage then ensure that...

Page 24: ...allation angle requirement is as follow MOUNTING Do not mount the battery pack and inverter at forward tilted back tilted side tilted horizontal or upside down positions Mounting Space Requirements Reserve enough space around the battery pack and inverter to ensure sufficient space for installation maintenance and heat dissipation ...

Page 25: ... pliers Wire stripper Phillips screwdriver torque range 0 2 N m L 140mm Rubber mallet Utility knife Cable cutter Crimping tool model PV CZM 22100 Cord end terminal crimper Disassembly and Assembly Tool model PV MS HZ open end wrench Vacuum cleaner Heat shrink tubing Heat gun Marker Measuring tape Bubble or digital level Personal Protective Equipment Safety gloves Safety goggles Anti dust respirato...

Page 26: ...e handles at the two sides take it out from the package carton Do not put the battery pack upside down on the ground 2 Place the battery positioning paper plate on the wall and stick the bottom to the floor and mark the positions of the two drill holes 3 Drill 2 holes on the wall with a diameter of 10mm and a depth of about 70mm ...

Page 27: ... bracket to the wall by using the SW10 hexagon sleeve Please use a level to ensure that the wall bracket is horizontal 5 Install the cardboard limit board on the battery pack with screw M5 12 X 2 tool T20 screwdriver torque 2 5Nm 6 Place the battery against the wall align the holes at the battery side to the screw holes of the wall bracket ...

Page 28: ... you will install extra batteries by side please repeat steps 1 6 and keep the distance between two batteries greater than 300mm The space between the left and the right battery is a recommended distance Keep the distance as short as you can if there is no influence to the operation gasket WARNING Risk of injury when lifting the battery pack or if it is dropped The Battery Pack is very heavy There ...

Page 29: ... top of the first battery pack 3 Place the battery positioning paper plate against the wall and the bottom with notch against the first battery pack Repeat steps 1 7 4 The bottom limit holes of the second battery will match the top screws of the first battery ...

Page 30: ...r MOUNTING The steps to mount the inverter are listed below 1 Fit the left and right side brackets onto the top of the battery 2 Attach the inverter to the mounting bracket Mount the supporting bracket at the bottom of the inverter ...

Page 31: ...1 and A2 with a depth of about 7cm and fix the wall bracket tightly to the wall with expansion screws Please repeat steps 8 9 to in stall the expanded battery 2 If the expansion batteries are installed upwards inverting the positioning paper plate and repeat the steps above 3 Please use a level to ensure that the wall bracket is horizontal The batteries can be stacked up to three batteries per colu...

Page 32: ...te according to the installed batteries and then repeat steps 3 9 to install the expansion batteries 6 4 Mounting the Wi Fi Module 1 Remove the Wi Fi Silicone dust cover from the left of the inverter 2 Tighten the Wi Fi module onto the inverter with screw M4 10 X2 Tool PH2 screwdriver torque 2 0 Nm ...

Page 33: ...d the battery pack are set to OFF Otherwise the high voltage of the product may result in electric shocks WARNING The device damage caused by incorrect cable connections is not covered under any warranty Only certified electricians are allowed to connect cables Operation personnel must wear proper PPE when connecting cables NOTICE The cable colors shown in the electrical connection diagrams provide...

Page 34: ...l breakers are switched off in transportation The following table is about DRM interface definition Mode Requirement DRM0 Operate the disconnection device DRM1 Do not consume power DRM2 Do not consume at more than 50 of rate power DRM3 Do not consume at more than 75 of rate power AND Source reactive power if capable DRM4 Increase power consumption subject to constraints from other active DRMs DRM5 D...

Page 35: ... Overview of the Battery Pack Connection Area The battery breaker is switched off before delivery a SMILE G3 BAT 10 1P OUTDOOR BAT Connectors BAT Connectors Communication Connectors BAT Connectors Battery Breaker Battery Power Button ...

Page 36: ...4 6 mm2 5 5 9 mm Purchased by the installer 5 2 Signal cable Standard network cable in the industry recommended type Cat5e FTP UV resistant for outdoor use 0 12 0 2 mm2 AWG26 AWG24 4 6 mm Purchased by the installer 6 3 Signal cable Multiple core outdoor shielded twisted pair cable 0 1 1 3 mm2 12 16 mm Purchased by the installer 7 AC power cable Three core L N and PE outdoor copper cable 8 10 mm2 4...

Page 37: ...ing terminal lug and crimp using a crimping tool Connect the OT terminal with ground point using the torque is 2 5 Nm with T20 screwdriver Connect the ground points between the battery and the inverter to ensure that the battery and the inverter have been grounded as shown in the figure below a SMILE G3 BAT 10 1P OUTDOOR M5 10 Screw 2 If the system occurs an earth fault the user will receive a mail...

Page 38: ... AC circuit breaker rating depends on the wiring design wire cross section area cable type wiring method ambient temperature inverter current rating etc De rating of the AC circuit breaker rating may be necessary due to self heating or if exposed to heat Depending on site system configuration to select an appropriate AC circuit breaker The maximum AC current of the inverters can be found in the fo...

Page 39: ...et element adapter and swivel nut together 3 Plug the AC connector into the socket for the AC connection and screw tight When doing so align the AC connector so that the key on the inverter AC socket is inserted into the keyway on the AC connector bush Backup Connection 1 Unscrew the swivel nut and take out the Seal ring from the threaded sleeve Insert the crimped conductors PE L and N into the co...

Page 40: ...l pole sensitive residual current monitoring unit RCMU detects alternating and direct differential currents The integrated differential current sensor detects the current difference between the neutral conductor and the line conductor If the current difference increases suddenly the inverter disconnects from the grid The function of the all pole sensitive residual current monitoring unit RCMU has been...

Page 41: ...cable with the CT Buckle the Grid CT on the live wire of the house For AC coupled systems and Hybrid coupled systems another PV CT is required Buckle the PV CT on the live wire of the PV inverter connecting point and insert the registered jack of the PV CT cable into the PV CT port on the SMILE G3 S5 INV NOTE The arrow of the CT should point to the grid port of the inverter from the grid or the PV...

Page 42: ...r without CT DTSU666 100 40mA Three single phase meter with 3 or 6 CT Meter wiring introduction 1 DTSU666 3 230V 5A Three phase meter without CT connection RJ45 Wiring at single phase home 6B B A 3A SMILE G3 INV LOAD PE PV Inverter GRID Optional PV Inverter LOAD CT NOTICE If the extra PV inverter are not used the system is suitable for DC mode If you use the extra PV inverter the system is suitabl...

Page 43: ...DTSU666 100 40mA Three phase meter with 3 or 6 CTs connection Wiring at single phase home Wiring at three phase home CT PV CT SMILE S6 HV INV Optional PV Inverter CT LOAD PE 39 36 33 9 6 3 37 34 31 7 4 1 SMILE S6 HV V PV Inverter 2 5 8 10 LOAD PV CT PV CT ...

Page 44: ...t CT When the meter is used as Grid meter please follow the steps below to complete the address setting by pressing the corresponding button and the number of times SET 1 Step1 ESC 2 Step2 When the meter is used as PV meter please follow the steps below to complete the address setting by pressing the corresponding button and the number of times D V is a p lu la e y NOTE If you have extra PV invert...

Page 45: ...click the button under the Grid Meter to turn the Meter in green When the system work mode is selected as AC or Hybrid click the buttons under the Grid Meter and PV side meter to turn the Meter in green Click Save and wait a few minutes to refresh the page When the Meter Model displays DTSU666 model the setting is successful Meter Information Grid Meter Meter CT CT Meter CT Ratio Meter Model PV si...

Page 46: ...rk mode is selected as AC or Hybrid both tick the Meter on the right of the Grid Meter and PV side meter Click Submit and enter the System information page to check the meter model The setting is successful if meter model is DTSU666 100 40mA 7 5 Communication Connection Communication connection port as follows NOTE It is forbidden to tick CT to modify the CT ratio ...

Page 47: ...inverter and COM port on the battery with communication cable 2 For meter wiring please read electricity meter wiring instructions of the meter If DRM support is specified the system may only be used in conjunction with a Demand Response Enabling Device DRED This ensures that the system implements the commands from the grid operator for active power limitation at all times The system and the Demand...

Page 48: ...l2 contains Do2_NO Do2_COM and Do2_NC corresponding to 4 5 and 6 respectively Channel 1 1 Do1_NO 2 Do1_COM 3 Do1_NC Channel 2 4 Do2_NO 5 Do2_COM 6 Do2_NC If using a generator unit with dry contact the dry contact can be wired to 1 Do1_NO and 2 Do1_COM of Channel 1 as shown in the diagram below If using a generator unit without dry contact no wiring is required 2 Place the COM connection cover agai...

Page 49: ...e to ground is higher than 200 Kῼ The inverter uses the D4 PV connectors Please follow the picture below to assemble the D4 connectors PV cable cross section requirements 4 6 mm2 7 7 Battery Power Connection Please follow the below steps for battery power connection 1 Disconnect the battery circuit breaker and secure it against reconnection 2 Take out the battery power cables which are provided by...

Page 50: ...upto two batteries per column Connect the power cables from battery 2 to battery 1 Connect the BMS communication cables from battery 2 to battery 1 Install extra SMILE G3 BAT 10 1P batteries indoor by side without stack Install extra SMILE G3 BAT 10 1P batteries outdoor by side without stack Install extra SMILE G3 BAT 10 1P batteries indoor with stack Install extra SMILE G3 BAT 10 1P batteries out...

Page 51: ...CTRICAL CONNECTION 52 Install extra SMILE BAT 5PH batteries Take out the terminal resistor provided by the inverter insert it to the unused communication port of the last battery SMILE G3 BAT 10 1P OUTDOOR ...

Page 52: ...53 WIFI SETTING 7 9 Install decorative cover Install the top decorative cover Install the Right decorative cover ...

Page 53: ...Install the Left plastic decorative cover ...

Page 54: ... Download and Install APP 1 Android device users can download the APP through major Android application markets such as Google Play 2 IOS device users can search for AlphaESS in App Store and download the APP AlphaESS APP ...

Page 55: ...WIFI SETTING 54 8 2 Overview of Functions for Installer Account ...

Page 56: ...n AlphaESS APP click the Wi Fi Configuration button and enter the Wi Fi configuration interface After that please check whether your mobile phone has connected to the system s hotspot If your mobile phone hasn t connected to the system s hotspot please open the Wi Fi network list Please find the hotspot named by the product SN in WLAN list then enter the password 12345678 and connect to it After succ...

Page 57: ...stem parameters Set basic parameters including PV capacity on the grid side the type of meters safety regulations and regional application standard Click Submit when the settings are complete NOTE The system will not be able to connect to the Internet without Wi Fi configur NOTE When the safety regulation is set as AS4777 2 the secondary sub options must be selected according to the region or local...

Page 58: ...e safety regulation in the same page After finishing the WIFI setting all the status can be found on the main page The firmware version also can be checked in the Firmware information The end user can contact the installer or service center for updating service ...

Page 59: ...ble connections The AC cable PV cable battery cable and communication cables are connected correctly securely and reliably 9 Unused power terminals Unused power terminals are blocked by watertight caps 9 2 Configuring the Safety Standard Please set the safety standard appropriate for your country or purpose via APP or Web during pilot run The safety standard must be set correctly If you select a s...

Page 60: ...arameters through the APP Wait about 3 minutes for the inverter to enter the grid connected state and observe the indicators states on the display panel of the inverter At this time the following 4 LEDs SYS TEM BATTERY METER COM on the display panel is always on 3 Check the UPS state of the product Switch off the external AC breaker between the grid and the inverter The inverter will enter the UPS ...

Page 61: ... left bottom of the inverter 4 Switch off the PV switch between the PV string and the inverter if there is any 5 Switch off the AC breaker between the inverter and the load 6 Switch off the AC breaker between the inverter and the grid WARNING After the inverter and battery pack is powered off the remaining electricity and heat may still cause electric shocks and body burns Therefore put on protective ...

Page 62: ...nce Criteria Maintenance Interval Product cleanliness The heatsink of the inverter are free from obstacles or dust Semiannually or once per year Product visible damage The inverter and battery pack are not damaged or deformed Semiannually Product running status 1 The inverter and battery pack operate with no abnormal sound 2 All parameters of the inverter and battery pack are correctly set Perform...

Page 63: ...the housing 3 Test the impedance of ground to PV PV BAT BAT with a multi meter If the imped ance is less than 25 Kῼ check whether the connection of each port is correct 4 Confirm to install the inverter according to the manual 5 Restart the inverter to see if the fault still exists If it still exists contact customer service 100008 GFCI_fault Restart the inverter to see if the fault still exists If...

Page 64: ... Make sure that the inverter is installed according to the manual and there is no shelter around the inverter 3 After the inverter is powered off and waiting for 30 minutes then restart it If the fault still exists please call the service center 100025 BAT_OVP Check whether the actual battery voltage exceeds the battery charging cut off voltage by more than 20V 100026 BAT_UVP Check whether the actua...

Page 65: ..._HW_OCP Restart the inverter to see if the fault still exists If it still exists please call the service center 100041 Output_DC_ over_voltage 100042 Output_short 1 Use a multimeter to test the impedance of the off grid output If it is small check whether the wiring is correct 2 Restart the inverter to see if the fault still exists If it still exists please call the service center 100043 Output_ove...

Page 66: ...center 10 2 2 Battery Protection Description LED Indictor Error Code LED Display Description Troubleshooting Yellow LEDs flash once per second 1 Temperature difference Wait for automatical recovery If the problem is not be solved yet please call the service center 3 Hardware error Stop discharging and charging until this code is eliminated and wait for the temperature to drop 4 Low temperature disch...

Page 67: ...l for service Error 10 LMU Disconnect master Reconnect the BMS communication cable Error 11 Software version inconsistent Call for service Error 12 Multi master Restart all batteries Error 13 MOS overtemperature Power off the battery and power on the battery after 30 minutes Error 14 Insulation fault Restart battery and in case the problem is not resolved call for service Error 15 Total voltage fau...

Page 68: ...ting bracket 11 2 Packing the Product If the original packaging is available put the battery pack or inverter inside it and then seal it by using adhesive tape If the original packaging is not available put the battery pack or inverter inside a suitable cardboard box and seal it properly 11 3 Disposing of the Product If the battery pack or inverter service life expires dispose of it according to t...

Page 69: ...ax Short Circuit Current Per MPPT 18 75 A 18 75 A NA MPPT Number 2 NA Max Input Strings Number Per MPPT 1 NA Battery Battery Type Li ion Battery Voltage Range 100 400 V Maximum Charging Power 5 kW Maximum Charge discharge current 60 A 60 A Communication CAN Output AC Back up Rated output power 5 kW 3 6 kW 5 kW Max Apparent Output Power 5 kVA 3 6 kVA 5 kVA Back up switch time 20 ms Rated output vol...

Page 70: ...tput Current 21 7 A 15 7 A 21 7 A Power Factor 0 99 0 8 leading 0 8 lagging Thdi 3 Protection Class l Overvoltage Category lll Efficiency Max Efficiency 97 EU Efficiency 96 2 Protection Anti Islanding Protection Integrated Insulation Resistor Detection Integrated Residual Current Monitoring Unit Integrated Output Over Current Protection Integrated Output Short Protection Integrated Output Overvoltage Pr...

Page 71: ...EC62040 1 IEC62109 1 2 AS3100 NB T 32004 EN61000 6 2 EN61000 6 3 Features PV Connection Vaconn H4 connectors Grid Connection Vaconn Back up Connection connectors BAT Connection connectors Communication LAN Wi Fi optional Warranty 5 years standard 12 2 Datasheet of Battery Pack SMILE G3 BAT 10 1P Item SMILE G3 BAT 10 1P Battery Type LFP LiFePO4 Weight 92kg Dimension W H D 442 391 130 mm Ingress Pro...

Page 72: ...C Discharge 10 T 50 C Relative Humidity 0 95 Monitoring Parameters System voltage current cell voltage cell temperature PCBA temperature Communication CAN and RS485 compatible Safety IEC62619 Cell IEC 62619 Pack Transportation UN38 3 Only for Germany Max charge discharge current de rating will occur related to temperature and SOC ...

Page 73: ...G3 S5 INV for example Indicates a signal cable Optional Connect the CT Grid Meter PV Meter Connect the meter Other SMILE G3 S5 INV Other SMILE G3 S5 INV NOTICE If the extra PV inverter is not used the system is suitable for DC mode If you have the extra PV inverter the system is suitable for AC or Hybrid mode ...

Page 74: ...r Vector in New Zealand Choose the correspond Regional Application Standard the power quality modes Volt var and Volt Watt will run automatically Only for Australia For compliance with AS NZS 4777 2 2020 please select from Australia A B C Please contact your local electricity grid operator for which region to select For changes to default settings please contact the installer or Alpha ESS ...

Page 75: ...ox such as Australia New Zealand South Africa etc Please follow local wiring regulations Example for grid systems without special requirements on electrical wiring connection The back up PE line and earthing bar must be grounded properly and effectively Otherwise the back up function may be abnormal when the grid fails ...

Page 76: ...Ehrlich Straß e 1a 63225 Langen Alpha ESS Australia Pty Ltd 61 1300 968 933 australia alpha ess com www alpha ess com au Unit 1 2 Ralph Street Alexandria NSW 2015 Alpha ESS Italy S r l 39 599 239 50 info alpha ess it www alpha ess it Via Loda 17 41013 Castelfranco Emilia MO Alpha ESS Korea Co Ltd 82 64 721 2004 korea alpha ess com 2F 19 4 Nohyeong 11 gil Jeju si Jeju do Republic of Korea Alpha ESS...