Summary of Contents for MP107

Page 1: ...MP615 MP107 MPEG 2 video player User guide WWW ALPEG COM ...

Page 2: ...4 2 Some examples 8 4 2 1 Example 1 8 4 2 2 Example 2 8 4 2 3 Example 3 9 4 2 4 Example 4 9 4 3 Recommendations 9 5 APPENDICES 9 5 1 Diagram of DB25 GPI parallel connector wiring dry contact 10 5 2 Language capacity 12 5 2 1 Sub scripts 13 5 2 2 Video file 13 5 2 3 Commands 13 6 HTML DIALOGUE PAGES 14 6 1 Main page 14 6 2 Network interface pages 15 6 3 Direct TCP IP reading control page 20 6 4 Scr...

Page 3: ... different modules A network connection An RS232 connection A GPI connector A Keypad connector This is a list of the equipment supplied A digital keyboard this guide a Y C cable a BNC BNC cable a RCA RCA stereo cable special MP107 cords mini din RCA mini din 3 RCA audio cord MP107 3 5mm jack RCA stereo ...

Page 4: ...nother sub script They are written in simple text file You can edit them directly in the HTML interface see script construction page of the mp615 reader or on your local computer with any text editor You should name them SC00 without any extensions and upload the script created in the player using an FTP service or a network explorer 3 1 2 Videos The video clips must be in MPEG 1 system or MPEG 2 ...

Page 5: ...een two connected computers even different ones Mac PC Unix that use the same FTP protocol there will be transfer of files on the network The size of the file to be transferred is unlimited however it often conditions the length of the connection Download means to import a document from a server to your computer Upload means to export send a document from your computer to a server It goes without ...

Page 6: ... 16 99 107 connection from a navigator ftp 10 16 99 107 if using specialised software In fact on the Web you are downloading files practically all the time but with a fundamental difference with respect to FTP the documents on the Web are only displayed temporarily for the time that you are viewing them 3 2 Controls and access methods 3 2 2 Network connection The network connection is the way to a...

Page 7: ...tronic GPI connector Enable a video numbered 1 to 5 to be read See the wiring diagram in the connection appendix ATTENTION If the player comes with a hardware key that connects to the electronic parallel GPI connector in utilisation without commands by dry contacts it is obligatory to set up this hardware key under pain of improper functioning of the player ...

Page 8: ... to be introduced Command wait n Example wait 5 wait 5 seconds 4 1 3 Goto Allows you to go to a line of data Command goto 1 Example goto 5 continue to execute script file at line n 5 4 1 4 y number Allows direct access to the command that is specified after the y number by an external module RS232 keyboard dry contact Connector Command y any command Example 55 play clips drop mpg 4 1 5 SC Allows a...

Page 9: ...ps drop mpg 1 2 wait 3 play clips pubsony mpg f wait 2 goto 1 This script plays the drop mpg video twice waits 3 seconds plays the pubsony mpg video and fixes the last image waits 2 seconds and starts again from the beginning line 1 4 2 2 Example 2 play clips drop mpg wait 3 goto 1 5 play clips pubsony mpg wait 2 goto 1 This script reads and loops the drop mpg video and waits 3 seconds between eac...

Page 10: ... clips pubsony mpg wait 2 R2 MPG clips drop mpg Goto 1 This script reads the pubsony mpg sequence waits 2 seconds orders the player that is identified as being n 2 to play the drop mpg sequence Warning the drop mpg sequence must exist on the slave player 4 3 Recommendations The script language allows some remarks to be added To do this you must start the line with a Important to remember Avoid Wai...

Page 11: ...ION If fewer channels are used the contacts must imperatively be earthed grounded The closing of contact 1 activates an action associated to a command number 1 example in the file SC00 1 play clips video1 mpg 1 k 1 4w 1 2 3 4 5 25 1 7 5 volts 0 volt Diode OA 90 Switches to stable position Diode OA 90 direct low voltage 0 3Volts ...

Page 12: ...act 3 activates an action associated to a command number 4 example in the file SC00 4 play clips video3 mpg The closing of contact 4 activates an action associated to a command number 8 example in the file SC00 8 play clips video4 mpg The closing of contact 5 activates an action associated to a command number 16 example in the file SC00 16 play clips video5 mpg ...

Page 13: ...L 60 Hz Outputs F4 Comp Y C F5 YUV F6 RGsB F7 SVGA Format 720x575 37 5Khz 70Hz Therefore to be operated externally a command like the one shown below should exist in the script 10 F1 the command in RS232 will be called up by using the following formula ID0CDE KEY10 Attention If your files were encoded in PAL format in 50Hz 25 images s you must imperatively set the player to F1 on the first line of...

Page 14: ...pages 6 1 Main page Open your Internet explorer and type in the following address of the player http 10 16 99 107 the screen shown below will appear Use this link to access the network interface page see diagram 4 Diagram 2 Main page ...

Page 15: ...l steps must be taken Network configuration of local computer is recommended IP Configuration sub network mask to enter in order to access player for the first time Default TCP IP configuration of player Default factory address is 10 16 99 107 Default subnet sub network mask is 255 255 0 0 Diagram 1 computer TCP IP parameters ...

Page 16: ...s accessible by the following type of PC address 192 168 0 10 After having accessed the interface you will get the following screen network interface 1 Current configuration Programmed configuration 1 access to configuration page Diagram 2 network interface page 1 ...

Page 17: ...Rev 1 1 Page 16 6 2 3 Network interface 2 factory parameters below 2 Change the configuration by modifying the 5 fields as shown in diagram 4 Diagram 3 network interface page 2 ...

Page 18: ...irst 2 groups of numbers from fields 2 and 4 are the same as those in field 1 IP address Fields to change to program the address 192 168 0 10 1 2 3 4 NOTE the first two groups of numbers in fields 2 and 4 are the same as in field 1 IP address 6 2 4 Network interface 2 programming Diagram4 In the event of a connection by modem router for remote administration control you must enter in this field th...

Page 19: ...or you are unable to find the address of the player you have the option of programming the player with the factory parameters TO DO THIS 1 Connect a standard computer PC keyboard to the violet socket miniDin PS2 2 Remove the black socket cover from the VGA connector that is next to the RS232 socket 3 Connect a VGA computer screen to this socket 4 You will see the command UTRAM 3 login appear 5 Typ...

Page 20: ...reading control page It is possible to control the Alpeg player by network with the following page By pressing on this button the player sends information about what it is currently doing This also happens if you press any other command ...

Page 21: ...itor page Writing the script is done entirely using the mouse intuitively all you have to do is choose the commands The MPEG2 files to be read are to be chosen and everything is to be saved in an exisitng script file or in a new script ...

Page 22: ...Rev 1 1 Page 21 Editing page with the SC00 file open ...

Page 23: ...Rev 1 1 Page 22 6 4 1 Script editing pages This is in text mode also called expert mode In this area all the scripts appearing in the player are listed Editing area Diagram 5 script editor ...

Page 24: ...Rev 1 1 Page 23 6 4 2 Opening a script in expert mode There is always for all players a default script text file called SC00 ...

Page 25: ...Rev 1 1 Page 24 The file that has been saved is shown here 6 4 3 Saving a script file To write a script please use the language chapter instructions ...

Page 26: ...age 25 6 5 Player status page RS232 address If the player is linked to another player the number of the player must be defined here This is how to give an address to the RS232 port of the player Diagram 6 Status ...

Page 27: ...Rev 1 1 Page 26 6 6 Factory preset page Restore the original TCP IP configuration the sound volume will be restored the next time the player is switched on ...

Page 28: ...Rev 1 1 Page 27 6 7 MP615 Front panel Lock key for hard disk Extractible hard disk ON OFF switch ...

Page 29: ...Rev 1 1 Page 28 6 8 MP107 Front panel On off button behind the hatch ...

Page 30: ... Page 29 6 9 MP107 Rear Panel General on off switch Power plug Network connection Dry contact socket RS232 input Not used Audio Stereo Output Direct video output Y C CVBS or YUV by adapter VGA output Not used ...

Page 31: ...front panel switch to avoid an accidental switching off of the front switch 0 locked position TCP IP network connector 10 100 baseT Table showing position of switches according to video outputs Composite Y C BNC miniDin Connectors RGsB connectors identical to YUV YUV 3 x BNCs Connectors VGA connectors DB15 ...

Page 32: ...eo output1 a goto wait x command or simply control the reading of a video file ID0CDE MPG clips filename mpg on player IDn reads the video sequence specified ID0CDE MPG clips drop mpg on master player reads the drop mpg sequence ID0CDE SEQxx On master player reads the SCxx script ID0CDE SEQ00 On master player read the SC00 script A SCnn script corresponding to a specific script must be present in ...

Page 33: ... maximum programming Very rich script language allowing for extreme flexibility External control DB25 dry contact for first 5 commands or keyboard sequence RS232 instant access to commands and sequences Ethernet TCP IP network interface 10 100base T Remote network control 32 sequences with a multiplexer dice as an option Direct control 16 touch keyboard for direct access to commands and sequences ...

Page 34: ...Rev 1 1 Page 33 ...