background image

Table of Contents 

Page 

 

Rod Operated Switch Installation................................................................................................................................................................................................. 2

    Switch Installation..........................................................................................................................................................................................................................2

    Handle Installation.........................................................................................................................................................................................................................2

    Cutting Connecting Rod..............................................................................................................................................................................................................2

    Connecting Rod Installation.......................................................................................................................................................................................................3

Cable Operated Mechanism Installation...................................................................................................................................................................................4

    Cable Operated Switch Installation.........................................................................................................................................................................................5

    Handle Installation.........................................................................................................................................................................................................................5

    Handle Mechanism Installation.................................................................................................................................................................................................5

Connecting Rod Adjustment Procedure....................................................................................................................................................................................6

Enclosure without Handle Cutout................................................................................................................................................................................................7

Door Catch Bracket Installation.....................................................................................................................................................................................................7

Conversion from Right Hand to Left Hand Operation (If Required).................................................................................................................................8

Line Terminal Guard Installation...................................................................................................................................................................................................8

Line Terminal Adapter Installation...............................................................................................................................................................................................8

Trailer Fuse Block Installation (400A Fuses)..............................................................................................................................................................................9

Trailer Fuse Block Installation (600A Fuses)............................................................................................................................................................................10

Bulletin 1494V/U Disconnect Switch Optional Accessory List.........................................................................................................................................11

  

Universal Disconnect Switch Installation Instructions (600A)

(Cat 1494V-DS600; Series D)

Tools Needed:

  1/2" Socket, 5/16" Allen Wrench, Hammer, Center Punch, File, Flat Head Screwdriver, Phillips Screwdriver, 9/32" Drill Bit, Needlenose Pliers, Hacksaw

Installation Instructions

WARNING:  

To prevent electrical shock, disconnect from power source before  installing  or  servicing.  Follow NFPA 70E requirements.  Install in suitable enclosure.  Keep free from 

contaminants.
Installation, adjustments, putting into service, use, assembly, disassembly, and maintenance shall be carried out by suitably trained personnel in accordance with applicable code of 
practice. In case of malfunction or damage, no attempts at repair should be made.  The product should be returned to the manufacturer for repair.  Do not dismantle the product. 

WARNING:  

The following procedures are critical to the proper operation of the disconnect handle and switch.  Failure to follow these steps can result in damage to the equipment and/or 

serious injury or death to the operator. 

Summary of Contents for D Series

Page 1: ...1494V DS600 Series D Tools Needed 1 2 Socket 5 16 Allen Wrench Hammer Center Punch File Flat Head Screwdriver Phillips Screwdriver 9 32 Drill Bit Needlenose Pliers Hacksaw Installation Instructions WARNING To prevent electrical shock disconnect from power source before installing or servicing Follow NFPA 70E requirements Install in suitable enclosure Keep free from contaminants Installation adjust...

Page 2: ...ting rods 5 1 1 2 Remove burrs 3 2 3 Install disconnect switch 7 IMPORTANT Apply grease to O Ring to retain into handle groove 7 11 lb in 0 79 1 2 Nm 6 D HOLD FLUSH TO IN SID E OF ENCLOSURE M EASURE TO IN SID E OF THE TOP OF ENCLOSURE TO P HANDLE HOLE BOTTO M HANDLE HOLE TAPE HOLD FLUSH TO IN SID E OF ENCLOSURE M EASURE TO IN SID E OF THE TOP OF ENCLOSURE TO P BOTT D 1 1 3 2 4 90 130 lb in 10 15 N...

Page 3: ...rod provides stiffening for the enclosure flange and mounting panel 4 3 Rotate rod to adjust Adjust to create 1 2 gap with spring bracket 1 2 Clearance 7 Connecting Rod Hitch Pin Handle Link 5 6 9 10 11 150 200 lb in 17 23 Nm Stiffening Rod Publication 1494V IN028A EN P March 2018 Drive Bar 2 Rotate connecting rod into drive bar 9 10 turns O P E N Verify that disconnect switch and handle are in OF...

Page 4: ...ism lever 1 2 Connecting Rod Cable Mechanism Lever 90 130 lb in 10 15 Nm 1 2 9 16 5 16 Fully seat bolt prior to attaching nut Lubricate 90 130 lb in 10 15 Nm Cable Operated Mechanism Installation 1 Publication 1494V IN028A EN P March 2018 IMPORTANT Verify that the cable assembly does not interfere with any mechanical and moving parts Keep the cable conduit away from all heat sources and current ca...

Page 5: ...ad forming screws 3 Assemble disconnect switch assembly to mounting plate Handle Mechanism Installation 4 Handle Installation Install gasket 1 2 3 3 7 11 lb in 0 79 1 2 Nm Install handle and mechanism bracket Install defeater lever Right Hand Flange Mounted Shown 60 80 lb in 6 8 9 0 Nm 1 Operate disconnect switch and verify that the handle and switch are in the ON position C L O S E D 2 Align conn...

Page 6: ...ry link of handle insert hitch pin and re test Repeat as necessary Re install link spring Install hitch pin clip Hitch Pin Clip Drive Bar 1 2 3 4 5 6 7 1 5 Move disconnect handle to the OFF position If switch does not fully open return handle to ON position Remove link spring and hitch pin to disengage the connecting rod from the primary link Turn connecting rod clockwise 1 or more full turns Re e...

Page 7: ...s for welding Projections can also be used as a guide for drilling holes in the enclosure door User to supply the hardware for fastening the bracket The bracket hardware must be inaccessible to unauthorized personnel Fasteners must provide the degree of ingress protection for the environmental rating of the enclosure Dimension K 3 4 to 1 When using large disconnect handle kit only 1494F M2 or S2 u...

Page 8: ...Required IMPORTANT Switch conversion to left hand operation requires left hand cable mechanism ATTENTION With switch in the CLOSED position drive mechanism should align with crossbar Line Terminal Guard Installation 90 130 lb in 10 15 Nm 1 2 6 10 lb in 0 68 1 1 Nm Line Terminal Adapter Installation Torque Range 1494U ALT600 25 lb in 2 8 N m 1 14 10 STR SOL 1 8 STR 2 14 SOL SOL 2 14 STR STR 2 12 SO...

Page 9: ... 400A Class H J R Fuses A 8 1 4 6 3 4 6 3 4 2 13 16 3 3 3 16 3 16 3 15 16 40 55 lb in 4 5 6 2 Nm 400A Fuses Class H J R 2 1 Fuse Installation 400 Amp Trailer Fuse Block 1494V FSV400 Torque lb in Nm Fuse 1 3 4 4 1 4 1 1 8 400 400 400 250 600 600 H R H R J 90 130 10 15 22 37 2 5 4 2 175 200 20 23 275 305 31 34 Amps Voltage Class Fuse Clip A Fuse Block Lug to Terminal Wire into Lug Publication 1494V ...

Page 10: ...p Installation Trailer Fuse Block Location 600A 250V 600V Class H R Fuses NOTE Refer to instructions provided with separately mounted fuse blocks Catalog Numbers 1491 N621 and 1491 R621 300 350 lb in 34 40 Nm 600 Amp Trailer Fuse Block 1494V FS600 Torque lb in Nm Fuse 4 3 8 600 250 600 J 90 130 10 15 300 350 34 40 175 200 20 23 275 305 31 34 Amps Voltage Class Fuse Bolt A Fuse Block Lug to Termina...

Page 11: ...ss H J 400A 250V 400A 600V 1401 N55 Class R 400A 250V 400A 600V 600A Fuses Class J Bolts directly to switch and fuse block no clips required Class H R Fuse clips included with separately mounted fuse blocks Cat Nos 1491 N621 and 1491 R621 Separately Mounted 1491 N621 600A Class H 1491 R621 600A Class R 1494U C64 4 Ft Cable 1494U C65 5 Ft Cable 1494U C66 6 Ft Cable Cable Mechanism 11 Universal Disc...

Page 12: ... N A LUGS Pkg Qty 3 TYPE TORQUE GAUGE AWG 1494R N10 1494R N11 1494R N12 Wire 325 LB IN CU ONLY 2 1 0 350 MCM For Separately Mounted Fuse Blocks 2 per kit Special Purpose Not For General Use Copper Lugs 1 1 0 500 MCM LUGS Pkg Qty 3 TYPE TORQUE GAUGE AWG 1494U LA600 Wire 325 LB IN AL CU 2 1 0 500 MCM LUGS Pkg Qty 3 TYPE TORQUE GAUGE AWG 1494U LM600 FOR LOAD SIDE ONLY Wire 35 LB IN AL CU 12 6 4 25 LB...